	<entry>
		<id>https://gunkies.org/w/index.php?title=FCO_CIBCI-I002&amp;diff=28733&amp;oldid=prev</id>
		<title>Vaxorcist: New page for CIBCI FCO #2</title>
		<link rel="alternate" type="text/html" href="https://gunkies.org/w/index.php?title=FCO_CIBCI-I002&amp;diff=28733&amp;oldid=prev"/>
				<updated>2023-02-27T07:22:36Z</updated>
		
		<summary type="html">&lt;p&gt;New page for CIBCI FCO #2&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;lt;pre&amp;gt;&lt;br /&gt;
_ FCO CIBCI-I002, Clusters of 6 or more CI/HSC nodes on SC008&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
+-----------------------------------------------------------------------------+&lt;br /&gt;
|                                                                             |&lt;br /&gt;
| _ _ _ _ _ _ _                           Level of Urgency         Page_1_    |&lt;br /&gt;
|| | | | | | | |                               +--+                  Of_12    |&lt;br /&gt;
||d|i|g|i|t|a|l|           FCO                 | I|                           |&lt;br /&gt;
||_|_|_|_|_|_|_|                               +--+                           |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
|                                                                             |&lt;br /&gt;
| FIELD  CHANGE  ORDER                         Number:   CIBCI-I002           |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
| Applicability: The L0118 Rev B* module should be installed on all CI750,    |&lt;br /&gt;
| CI780, CIBCI, &amp;amp; HSCxx nodes used in VAXclusters of 6 (six) or more CI/HSC   |&lt;br /&gt;
| nodes connected to a common SC008 Star Coupler.   L0118s should replace all |&lt;br /&gt;
| L0100 Rev D* link modules; L0100 Rev E* can coexist with L0118s except in   |&lt;br /&gt;
| greater than 16 node environment.                                           |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
| Problem/Symptom:  Clusters of 6 or more CI/HSC nodes on SC008 may exhibit   |&lt;br /&gt;
| CI-PATH NO_RSP or NAK, ARB-TIMEOUTS, and VC-CLOSURE.  L0118 (&amp;amp; L0100 Rev E*)|&lt;br /&gt;
| corrects adjacent-node collision &amp;amp; arb problems. * FIX DETAILS ON PAGE 2. * |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
| Quick Check:   Check that link module is part number L0118.                 |&lt;br /&gt;
|                                                                             |&lt;br /&gt;
|                                                                             |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
| Compatibility/Prerequisite FCO:                   | Est. Time to Install:   |&lt;br /&gt;
| CI750-I005, CI780-I006, HSC50-I009,HSC70-I001     |    1 hour per node      |&lt;br /&gt;
|___________________________________________________|_________________________|&lt;br /&gt;
| Special Tools or Test Equipment:  See page 2.                               |&lt;br /&gt;
|                                                                             |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
|                        FCO     Parts   Information                          |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
| Order by          Quantity:        Part Number:        Description:         |&lt;br /&gt;
| FCO Kit#:                                                                   |&lt;br /&gt;
| EQ-01454-05         1              L0118 (Rev B)       Link Module          |&lt;br /&gt;
| EQ-01454-04         1                                  FA-04740-01/05       |&lt;br /&gt;
| FA-04740-03         1                                  FCO Document         |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
|EQ Kit Variation System/Option Applic:    N/A                                |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
|                            Approvals                                        |&lt;br /&gt;
|_____________________________________________________________________________|&lt;br /&gt;
|   CSSE Engineer    |  F.S.  Product Safety    |   F.S.  Logistics           |&lt;br /&gt;
|   Bob Brassard     |  Robert Brister          |   Ed Duggan                 |&lt;br /&gt;
|____________________|__________________________|_____________________________|&lt;br /&gt;
|   CSSE Manager     | F.S. Microfiche Libraries|  Affected Population:       |&lt;br /&gt;
|   Jan Sicard       |                          |  12,000/2,000               |&lt;br /&gt;
|____________________|   EP-FSNVX-LB  VAX       |---------------------------- |&lt;br /&gt;
|   MicroMedia Pub.  |                          |  Initial Kitting:           |&lt;br /&gt;
|   Ray LeBlanc      |   VAXnotes               |  12,000/2,000               |&lt;br /&gt;
|____________________|   STARS                  |____________________________ |&lt;br /&gt;
|   Revision:        |                          |  Hardcopy Publication:      |&lt;br /&gt;
|        A           |                          |  2,000                      |&lt;br /&gt;
|____________________|                          |_____________________________|&lt;br /&gt;
|  FCO Release Date  |                          |  Parts Availability:        |&lt;br /&gt;
|  2-JUN-88          |                          |  May 1988                   |&lt;br /&gt;
+-----------------------------------------------------------------------------+&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  2  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
        PROBLEMS/SYMPTOMS: Continued from Page 1.&lt;br /&gt;
        -----------------------------------------&lt;br /&gt;
        SOLUTION SUMMARY - L0118 DESIGN AND L0100 E* ECOS&lt;br /&gt;
                # - Denotes changes incompatible with L0100-D1, or CIBCA&lt;br /&gt;
                &amp;quot;7-tick DELTA-TIME mode; and controlled by &amp;quot;COMPATIBILITY&lt;br /&gt;
                7/10-tick&amp;quot;  switch on L0100-E1/E2 or L0118.&lt;br /&gt;
&lt;br /&gt;
        1.# BASIC QUIET-SLOT extended from 7 to 10 ticks (tick=byte=114 ns.,&lt;br /&gt;
            change = 800 ns. to 1140 ns.) to fix adjacent node collision&lt;br /&gt;
            problem at 40% CI-path utilization caused by L0100 Tx-start/Rx-&lt;br /&gt;
            detect logic delays when such nodes simultaneously arbitrate.&lt;br /&gt;
&lt;br /&gt;
        2.# HIGH/LOW-PRIORITY (Round-ROBIN) ARBITRATION COUNTER logic fixed&lt;br /&gt;
            to prevent &amp;quot;false BEATEN-BY-NODE-0&amp;quot; detection during ACK-&lt;br /&gt;
            TURNAROUND carrier-delay, resulting in biasing arb-wins to&lt;br /&gt;
            low-nodes.  Fix requires QUIET-SLOT change, and must be&lt;br /&gt;
            applied to all L0100 to prevent arbitration biasing.&lt;br /&gt;
&lt;br /&gt;
        3. # EXTEND ACK-TURNAROUND TIME (INFO-to-ACK PACKET delay) to&lt;br /&gt;
            ensure CI-sender (INFO-PKT) ready to receive ACK, under&lt;br /&gt;
            worst-case (short,fast) propagation delays, such as with&lt;br /&gt;
            SC004 (dual-CI750) and short-CI-cables (6-10 meter).&lt;br /&gt;
            Fix requires QUIET-SLOT change.&lt;br /&gt;
&lt;br /&gt;
        4.  Fix SYNC-DETECT &amp;quot;PAL&amp;quot; to prevent lock-up during CI-carrier&lt;br /&gt;
            &amp;quot;flood&amp;quot;, an infrequent CI-LINK failure mode.&lt;br /&gt;
&lt;br /&gt;
        5.  EXTEND &amp;quot;TRAILER TRANSMIT TIME&amp;quot; to ensure at least 5 bytes&lt;br /&gt;
            of trailer (after CRC) sent, instead of 3.5 bytes.&lt;br /&gt;
&lt;br /&gt;
        6.  EXTEND HEADER JUMPER (not used in current CI applic.) was&lt;br /&gt;
            non-functional: Fix.&lt;br /&gt;
&lt;br /&gt;
        7.  ALTER-DELTA-TIME JUMPER (7/16-tick quiet-slot) was&lt;br /&gt;
            non-functional: Fix.  Not currently used, but intended&lt;br /&gt;
            for extended CI-cabling lengths, or fiber.&lt;br /&gt;
&lt;br /&gt;
        8.  ARBITRATION STATUS REPORTING enhanced to distinguish&lt;br /&gt;
            ARB-TIMEOUT from &amp;quot;fail to xmit after successful ARB&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
        9.  CI20 ONLY: CRC-COUNT RESET failed on SELF-DIRECTED&lt;br /&gt;
            packets: Fix.&lt;br /&gt;
&lt;br /&gt;
        10. MISCELLANEOUS L0100 Print-Set logic-drawing clean-up,&lt;br /&gt;
            marginal logic-design improvement, for benefit of&lt;br /&gt;
            future CIxxx chip-designs (CIBCA...) based on L0100.&lt;br /&gt;
&lt;br /&gt;
        SPECIAL TOOLS:  Continued from page 1.&lt;br /&gt;
        --------------------------------------&lt;br /&gt;
        Field Service Tool Kit&lt;br /&gt;
        VELOSTAT Electrostatic Field Service Kit (P/N 29-26246-00)&lt;br /&gt;
        Loopback Attenuators (12-19907-01)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  3  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
        PARTS LIST:  Continued from page 1.&lt;br /&gt;
        ----------------------------------&lt;br /&gt;
        Order by       Quantity:        Part Number:           Description:&lt;br /&gt;
        FCO Kit#:&lt;br /&gt;
&lt;br /&gt;
        EQ-01454-05        1            L0118 (Rev B1/B2)      Link Module&lt;br /&gt;
&lt;br /&gt;
        FA-04740-06        1                                   Inst. sheet for&lt;br /&gt;
                                                               ordering kits&lt;br /&gt;
&lt;br /&gt;
        EQ-01454-04        1            FA-04740-01            CI750 FCO Doc.&lt;br /&gt;
                           1            FA-04740-02            CI780 FCO Doc.&lt;br /&gt;
                           1            FA-04740-03            CIBCI FCO Doc.&lt;br /&gt;
                           1            FA-04740-04            HSC50 FCO Doc.&lt;br /&gt;
                           1            FA-04740-05            HSC70 FCO Doc.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
        CIBCI OPTION LEVEL REVISION CHART&lt;br /&gt;
        ---------------------------------&lt;br /&gt;
&lt;br /&gt;
        CIBCI           A1         B1&lt;br /&gt;
        --------------------------------------------------------------&lt;br /&gt;
        L0100**         D1,(B2*)   D,(B2*)E&lt;br /&gt;
        L0118**                    B1,B2&lt;br /&gt;
        L0101           H1         J1,K1&lt;br /&gt;
        L0400           B1,C1      B1,C1&lt;br /&gt;
        T1017           B1         C1,D1&lt;br /&gt;
        T1018           B1         C1&lt;br /&gt;
        Microcode&lt;br /&gt;
         CI780.BIN      Rev 5.0    Rev 7,8&lt;br /&gt;
        BACKPLANE       B1,C1      B1,C1&lt;br /&gt;
        POWER SUPPLY    A          A&lt;br /&gt;
&lt;br /&gt;
        ---------------------------------------------------------------&lt;br /&gt;
        * (NOTE) &amp;quot;B2&amp;quot; is being marked on &amp;quot;B&amp;quot; etch and is equal to &amp;quot;D1&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
        **(NOTE) L0118 is enhanced L0100 replacement and can be used as&lt;br /&gt;
          &amp;quot;universal spare&amp;quot;.  L0118 is required to support &amp;gt;16 node&lt;br /&gt;
          functionality.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  4  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
                LINK MODULE UTILIZATION/SWITCH SETTINGS MATRIX&lt;br /&gt;
                ----------------------------------------------&lt;br /&gt;
        --------------------------------------------------------------------&lt;br /&gt;
        |                |     1 - 5 NODES       |     6 - 16 NODES        |&lt;br /&gt;
        |   OPTION       |-----------------------|-------------------------|&lt;br /&gt;
        |                | MODULE/REV/SLOT-COUNT |  MODULE/REV/SLOT-COUNT  |&lt;br /&gt;
        |----------------|-----------------------|-------------------------|&lt;br /&gt;
        | CI7XX, CIBCI,  | L0100 REV &amp;quot;D&amp;quot;         |  L0100 REV E @ 10 TICK  |&lt;br /&gt;
        | HSCXX          | L0100 REV &amp;quot;E&amp;quot; @ 7 TICK|                         |&lt;br /&gt;
        |                | L0118 @ 7 TICK        |  L0118 @ 10 TICK        |&lt;br /&gt;
        |----------------|-----------------------|-------------------------|&lt;br /&gt;
        | CIBCA-AA       | T1025 @ 7 TICK        |  T1025 @ 10 TICK        |&lt;br /&gt;
        |________________|_______________________|_________________________|&lt;br /&gt;
&lt;br /&gt;
        NOTE:  If all nodes in the VAXcluster system have 10 tick capability&lt;br /&gt;
        (I.E., L0118, L0100 Rev &amp;quot;E&amp;quot; and/or CIBCA-AA and NO L0100 Rev &amp;quot;D&amp;quot;),&lt;br /&gt;
        then all nodes should be set to 10 tick mode regardless of the&lt;br /&gt;
        VAXcluster system size.&lt;br /&gt;
&lt;br /&gt;
        L0100  -  Rev &amp;quot;E&amp;quot;  -  See page 7, step 10 for 7/10-TICK Switch setup.&lt;br /&gt;
&lt;br /&gt;
        L0118  -  Rev &amp;quot;B&amp;quot;  -  See page 7, step 10 for 7/10-TICK, Cluster-size&lt;br /&gt;
                              Switch set-up, and Misc. Function Jumpers.&lt;br /&gt;
&lt;br /&gt;
        CIBCA-AA           -  Add Jumper from E11 to E41 on VAXBI Backplane&lt;br /&gt;
                              for &amp;quot;10-TICK INCOMPATIBLE&amp;quot; mode operation.&lt;br /&gt;
                              Verify no jumpers D29-D59 and D30-D60 for cluster-&lt;br /&gt;
                              size (NODE-COUNT) of 16 or less.   Refer to&lt;br /&gt;
                              CIBCA User Guide Pg. 2-10 to 2-13 for set-up.&lt;br /&gt;
&lt;br /&gt;
        CI-LINK MODULE FCO INSTALLATION SUMMARY&lt;br /&gt;
        ---------------------------------------&lt;br /&gt;
        **********************************************************************&lt;br /&gt;
        *          INCOMPATIBILITY WARNING  -  L0100-E1/E2 &amp;amp; L0118           *&lt;br /&gt;
        *          -----------------------------------------------           *&lt;br /&gt;
        *  The new L0100-E1/E2 and L0118 &amp;quot;10-TICK-MODE&amp;quot; design changes are   *&lt;br /&gt;
        *  *** INCOMPATIBLE *** with current L0100-D1 design, and CI/HSC-    *&lt;br /&gt;
        *  LINK modules (L0100-E, CIBCA, L0118) set to &amp;quot;7-TICK-MODE&amp;quot;.        *&lt;br /&gt;
        *  Mixed &amp;quot;7 and 10-TICK-MODE&amp;quot; CI-LINK operation can have severe      *&lt;br /&gt;
        *  impact on CI-arbitration performance and collision-rate (NO_RSP). *&lt;br /&gt;
        *  For this reason, DEC does not support &amp;quot;10-TICK-MODE&amp;quot; CI-LINK      *&lt;br /&gt;
        *  ROLLING-UPGRADES, thus requiring a CLUSTER SHUTDOWN to &amp;quot;ENABLE&amp;quot;   *&lt;br /&gt;
        *  10-TICK-MODE ** ONLY ** after all CI/HSC-nodes have been FCO'd.   *&lt;br /&gt;
        *                                                                    *&lt;br /&gt;
        *       NOTE: High-availability customer exceptions to CLUSTER-      *&lt;br /&gt;
        *       SHUTDOWN &amp;quot;rule&amp;quot; should be referred to CSSE for advice on     *&lt;br /&gt;
        *       minimizing risks; but DEC will not assume any liabilities    *&lt;br /&gt;
        *       for lost data/time with such CLUSTER upgrade programs.       *&lt;br /&gt;
        **********************************************************************&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  5  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
        o Forecast and obtain sufficient CI/HSCxx L0100 FCO kits for all CI7x0,&lt;br /&gt;
          CIBCI, HSCxx Cluster Nodes, ensuring availability of 1 (one) spare&lt;br /&gt;
          for every 10 (ten) FCO kits.  FCO kits should NOT BE &amp;quot;P1 ORDERED&amp;quot;,&lt;br /&gt;
          but should be ordered according to the Corporate Implementation&lt;br /&gt;
          Plan.  CIxxx Functional Diags (EVGAA/B) from VAX Diag. Rel #31 are&lt;br /&gt;
          also recommended for checkout.&lt;br /&gt;
&lt;br /&gt;
        o Study SWITCH/JUMPER SET-UP Procedures for L0100, L0118, and CIBCA&lt;br /&gt;
          T1025 modules for adjusting the following CI-LINK functions/modes:&lt;br /&gt;
&lt;br /&gt;
                - &amp;quot;7/10-TICK&amp;quot; DELTA-TIME/QUIET-SLOT:&lt;br /&gt;
                        + L0118         Page 7. Step 10&lt;br /&gt;
                        + L0100-E       Page 7, Step 10&lt;br /&gt;
                        + T1025/CIBCA   Page 7, Step 10 and&lt;br /&gt;
                                        CIBCA USER'S GUIDE Pg. 2-12&lt;br /&gt;
                - CLUSTER-SIZE of 16/32 NODES:&lt;br /&gt;
                        + L0118         Page 7, Step 10&lt;br /&gt;
                        + L0100-E       NOT APPLICABLE&lt;br /&gt;
                        + T1025/CIBCA   Page 7, Step 10 and&lt;br /&gt;
                                        CIBCA USER'S GUIDE Pg. 2-13&lt;br /&gt;
                - L0118 CI-LINK-MODE JUMPERS: Page 7, Step 10.&lt;br /&gt;
&lt;br /&gt;
        o Install L0118 set to &amp;quot;7-TICK/COMPATIBLE-MODE&amp;quot; in all CI780, CI750,&lt;br /&gt;
          CIBCI, and HSC50/70 Cluster nodes.  There are no prerequisite/co-&lt;br /&gt;
          requisite CIxxx or HSCxx FCOs (modules or microcode) required for&lt;br /&gt;
          L0118 upgrade in &amp;quot;7-TICK 16-NODE MODE&amp;quot;, but CI780.BIN Version V8.0&lt;br /&gt;
          and CIBCA.BIN Version V5.3 are recommended.&lt;br /&gt;
&lt;br /&gt;
        o Schedule &amp;amp; perform cluster shutdown after all non-CIBCA nodes are&lt;br /&gt;
          upgraded/FCO'd, and have been tested and verified to function in&lt;br /&gt;
          &amp;quot;7-TICK-MODE&amp;quot; operation under VMS.  VMS system-testing is important&lt;br /&gt;
          to early detection and repair of any DOA FCO modules, prior to&lt;br /&gt;
          disrupting VAXcluster for CI-LINK 7-to-10-TICK mode-change.&lt;br /&gt;
&lt;br /&gt;
                *********************************************************&lt;br /&gt;
                *       IMPORTANT  NOTE  ===  IMPORTANT NOTE            *&lt;br /&gt;
                *  Customer should be involved or perform all CLUSTER-  *&lt;br /&gt;
                *  wide or node-specific VAX and HSC STARTUPS, BOOTS,   *&lt;br /&gt;
                *  and SHUTDOWNS.                                       *&lt;br /&gt;
                *********************************************************&lt;br /&gt;
&lt;br /&gt;
        o Switch all L0100-E, L0118, and T1025/CIBCA to &amp;quot;10-TICK-MODE&amp;quot;&lt;br /&gt;
          &amp;quot;INCOMPATIBLE&amp;quot; operation.  Ensure all CIs and HSCs are powered-off&lt;br /&gt;
          before changing switches/jumpers.  Refer to appropriate FCO steps.&lt;br /&gt;
          Any planned CI-NODE-ADDRESSS changes should also be made at this&lt;br /&gt;
          time, with consideration of VMS SYSGEN and DECNET parameter changes&lt;br /&gt;
          required on reboot.&lt;br /&gt;
&lt;br /&gt;
        o Reboot cluster, with customer consent, starting with HSCs.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  6  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
                    CI-LINK MODULE FCO INSTALLATION PROCEDURE&lt;br /&gt;
                    -----------------------------------------&lt;br /&gt;
&lt;br /&gt;
        1.  Shutdown the system by executing the Shutdown Command Procedure,&lt;br /&gt;
            CUSTOMER SHOULD PERFORM THIS.&lt;br /&gt;
&lt;br /&gt;
            $  &amp;quot;@SYS$SYSTEM:SHUTDOWN.COM&amp;quot;&lt;br /&gt;
&lt;br /&gt;
        2.  Control &amp;lt;CTRL&amp;gt; ) and HALT the system.&lt;br /&gt;
&lt;br /&gt;
        3.  Power off the system by typing &amp;gt;&amp;gt;&amp;gt;POFF.&lt;br /&gt;
&lt;br /&gt;
        4.  Open the rear doors of the CPU cabinet and the expander&lt;br /&gt;
            cabinet containing the CI (CIPA) box.&lt;br /&gt;
&lt;br /&gt;
        5.  Set main power circuit breaker of the CPU cabinet to the&lt;br /&gt;
            OFF (0) position.&lt;br /&gt;
&lt;br /&gt;
        6.  Set the 877 power controller main power circuit breaker&lt;br /&gt;
            of the expander cabinet containing CI (CIPA) box to the&lt;br /&gt;
            OFF (0) position.&lt;br /&gt;
&lt;br /&gt;
        7.   Disconnect all four BNCIA cables for this VAX 8XX0 node&lt;br /&gt;
             at the SC008.  Using the loopback attenuators connect:&lt;br /&gt;
&lt;br /&gt;
             Transmit Path &amp;quot;A&amp;quot; (TA) to Receive Path &amp;quot;A&amp;quot; (RA)&lt;br /&gt;
             Transmit Path &amp;quot;B&amp;quot; (TB) to Receive Path &amp;quot;B&amp;quot; (RB)&lt;br /&gt;
&lt;br /&gt;
        ****************************************************************&lt;br /&gt;
        *                        C A U T I O N                         *&lt;br /&gt;
        *                                                              *&lt;br /&gt;
        *       The L0118 module, as all VAX modules do,               *&lt;br /&gt;
        *       contains electrostatic discharge sensitive             *&lt;br /&gt;
        *       devices (ESDS).  The use of the VELOSTAT kit           *&lt;br /&gt;
        *       is essential to prevent damage which may not           *&lt;br /&gt;
        *       be noticed immediately.                                *&lt;br /&gt;
        *                                                              *&lt;br /&gt;
        ****************************************************************&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  7  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
        8.  Set up VELOSTAT KIT&lt;br /&gt;
&lt;br /&gt;
            a.  Unfold the VELOSTAT mat to full size (24&amp;quot; x 24&amp;quot;).&lt;br /&gt;
            b.  Attach the 15 foot ground cord to the VELOSTAT&lt;br /&gt;
                snap fastener on the mat.&lt;br /&gt;
            c.  Attach the alligator clip end of the ground cord&lt;br /&gt;
                to a good ground on the VAX 8X00 system.&lt;br /&gt;
            d.  Attach the wrist strap to either wrist and the&lt;br /&gt;
                alligator clip to a convenient portion of the mat.&lt;br /&gt;
&lt;br /&gt;
        9.  Remove the L0100 or L0118 module from its CPU option slot&lt;br /&gt;
            and place it on the mat.  Check the revision and module type:&lt;br /&gt;
                - L0100-E1/E2, or L0118, reinstall in same slot, and&lt;br /&gt;
                  go to step 11 (no upgrade needed).&lt;br /&gt;
                - L0100 below Rev. E1/E2, go to step 10 to continue upgrade.&lt;br /&gt;
&lt;br /&gt;
            Record old CI-NODE ADDRESS settings on SW1 and SW2 switches&lt;br /&gt;
            (8-switch DIP on module handle).&lt;br /&gt;
&lt;br /&gt;
        10. With L0118 (EQ-01454-05) on ESD Mat, configure and verify CI-LINK&lt;br /&gt;
            mode jumpers/switches for &amp;quot;7-TICK COMPATIBLE&amp;quot; MODE operation.&lt;br /&gt;
            The L0118 also contains CLUSTER-SIZE switch and 4 (four) jumpers&lt;br /&gt;
            for MISC-FUNCTIONAL-MODES which should be checked.   Install the&lt;br /&gt;
            new L0118 in the CIxxx option slot.&lt;br /&gt;
&lt;br /&gt;
                *************************************************************&lt;br /&gt;
                *                    IMPORTANT  -  NOTE                     *&lt;br /&gt;
                *  Copy old CI-NODE ADDRESS to new L0100/L0118.             *&lt;br /&gt;
                *  Ensure &amp;quot;7-TICK COMPATIBLE&amp;quot; mode is ENABLED/SET to avoid  *&lt;br /&gt;
                *  CI-PATH errors with L0100-D1 or other &amp;quot;7-TICK&amp;quot; CI/HSC    *&lt;br /&gt;
                *  nodes.  The &amp;quot;10-TICK INCOMPATIBLE&amp;quot; mode cannot be used   *&lt;br /&gt;
                *  with L0100-D1 in cluster.   Default L0100/L0118 manuf.   *&lt;br /&gt;
                *  switch setting should be &amp;quot;7-TICK COMPATIBLE&amp;quot; mode.       *&lt;br /&gt;
                *************************************************************&lt;br /&gt;
&lt;br /&gt;
            SET L0100-E1 COMPATIBILITY JUMPER AS FOLLOWS:&lt;br /&gt;
            ---------------------------------------------&lt;br /&gt;
            o 7/10-TICK COMPAT. MODE SET BY 1 JUMPER @ E177 stake-pins.&lt;br /&gt;
&lt;br /&gt;
                - &amp;quot;7-TICK    COMPAT.-MODE&amp;quot;: jumper E177-11 to E177-12&lt;br /&gt;
                - &amp;quot;10-TICK INCOMPAT.-MODE&amp;quot;: jumper E177-9  to E177-10&lt;br /&gt;
&lt;br /&gt;
            o NO CLUSTER-SIZE OR FUNCTION-MODE JUMPERS/SWITCHES.&lt;br /&gt;
&lt;br /&gt;
            o L0100-E1 QUICK-CHECK (PART-REVISION VERIFY):&lt;br /&gt;
&lt;br /&gt;
                - ECO wires at E177-13 and E177-9.&lt;br /&gt;
                - STAKE-PINS (for jumper) @ E177-9,10,11,12.&lt;br /&gt;
                - ETCH REV-C: P/N &amp;quot;50-14430C-0&amp;quot; marking.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  8  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
               &amp;quot;ECO-FIX OFF&amp;quot;                           &amp;quot;ECO-FIX ON&amp;quot;&lt;br /&gt;
                 &amp;quot;7-TICK&amp;quot;                               &amp;quot;10-TICK&amp;quot;&lt;br /&gt;
               &amp;quot;COMPATIBLE&amp;quot;                           &amp;quot;INCOMPATIBLE&amp;quot;&lt;br /&gt;
              20               +-+                20              12 11&lt;br /&gt;
            ...................|.|..            ........................&lt;br /&gt;
            |  . . . . . . . . | | |            |  . . . . . . . . . . |&lt;br /&gt;
            |         E177         |            |         E177         |&lt;br /&gt;
            |  . . . . . . . . . . |            |  . . . . . . . . . . |&lt;br /&gt;
            |......................|            |..................|.|.|&lt;br /&gt;
               1               9  10               1               | |&lt;br /&gt;
                                                                   +-+&lt;br /&gt;
&lt;br /&gt;
            SET L0100-E2 SWITCH SETTINGS AS FOLLOWS:&lt;br /&gt;
            ----------------------------------------&lt;br /&gt;
            o 7/10-TICK COMPAT. MODE SET BY DIP-SWITCH SW3-1 LOCATED AT&lt;br /&gt;
              TOP CENTER OF L0100-E2 TO RIGHT OF E118:&lt;br /&gt;
&lt;br /&gt;
                - &amp;quot;7-TICK    COMPAT.,ECO OFF&amp;quot;:  SW3-1 SWITCH &amp;quot;OFF&amp;quot;&lt;br /&gt;
                - &amp;quot;10-TICK INCOMPAT.,ECO ON &amp;quot;: SW3-1 SWITCH &amp;quot;ON&amp;quot; .&lt;br /&gt;
                        NOTE: SW3-2 IS NOT USED, BUT SET SAME&lt;br /&gt;
                        AS SW3-1 TO AVOID CONFUSION.&lt;br /&gt;
&lt;br /&gt;
            o NO CLUSTER-SIZE OR FUNCTION-MODE JUMPERS/SWITCHES.&lt;br /&gt;
&lt;br /&gt;
            o L0100-E2 QUICK-CHECK (PART-REVISION VERIFY):&lt;br /&gt;
&lt;br /&gt;
                - SW3 DUAL-SWITCH-DIP-PACK AT TOP-CENTER, RIGHT OF E118.&lt;br /&gt;
                - ETCH REV-D: P/N &amp;quot;50-14430-0-0 D1-P4&amp;quot; marking.&lt;br /&gt;
&lt;br /&gt;
            SET L0118 SWITCH/JUMPER SETTINGS AS FOLLOWS:&lt;br /&gt;
            --------------------------------------------&lt;br /&gt;
                ****************************************************&lt;br /&gt;
                *  NOTE: REFER TO L0118 FIGURES ON FCO PAGES 11    *&lt;br /&gt;
                *  AND 12 FOR SW3 AND JUMPERS W1-W4 LOCATION.      *&lt;br /&gt;
                ****************************************************&lt;br /&gt;
&lt;br /&gt;
            o 7/10-TICK COMPAT. MODE SET BY DIP-SWITCH SW3-4 LOCATED AT&lt;br /&gt;
              TOP CENTER OF L0118 TO LEFT (BELOW IF VERTICAL) OF 2 CI-&lt;br /&gt;
              NODE-ADDRESS 8-SWITCH PACKS.&lt;br /&gt;
                - &amp;quot;7- TICK   COMPAT.,ECO OFF&amp;quot;: SW3-4 SWITCH &amp;quot;OFF&amp;quot;.&lt;br /&gt;
                - &amp;quot;10-TICK INCOMPAT.,ECO ON&amp;quot; : SW3-4 SWITCH &amp;quot;ON&amp;quot; .&lt;br /&gt;
                - SWITCHES SW3-2 AND SW3-3 MUST BE &amp;quot;OFF&amp;quot; (AFFECTS&lt;br /&gt;
                  DELTA-TIME/QUIET-SLOT).&lt;br /&gt;
&lt;br /&gt;
            o CLUSTER-SIZE FOR 16/32-NODE ADDRESSING AND ARBITRATION IS&lt;br /&gt;
              CONTROLLED BY SWITCH SW3-1.  DEFAULT = 16-NODE-MODE = &amp;quot;OFF&amp;quot;.&lt;br /&gt;
                - 16-NODE MODE (DEFAULT WITH NO CISCE): SW3-1 &amp;quot;OFF&amp;quot;.&lt;br /&gt;
                - 32-NODE MODE (CISCE 24-NODE CLUSTER): SW3-1 &amp;quot;ON&amp;quot; .&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  9  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
            o L0118 FUNCTION-MODE JUMPERS W1-W4 DEFAULT SETTINGS CHECK:&lt;br /&gt;
                View module with HANDLE-UP and FINGERS-DOWN.&lt;br /&gt;
                Refer to L0118 Figures on FCO pages 11 and 12.&lt;br /&gt;
&lt;br /&gt;
                - L0118-B1 HAS ECO-WIRES ON E83-3 and E150-1:&lt;br /&gt;
                        = W1 located left of E2: plugged on left 2&lt;br /&gt;
                          stake-pins, marked with &amp;quot;box&amp;quot;.&lt;br /&gt;
                        = W3 located between E54 and E75: plugged on&lt;br /&gt;
                          horizontal stake-pins, marked with &amp;quot;box&amp;quot;.&lt;br /&gt;
                        = W2 &amp;amp; W4 located as 4 stake pins below E24&lt;br /&gt;
                          and E62: W2 &amp;amp; W4 &amp;quot;OUT&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
                - L0118-B2 HAS NO ECO-WIRES TO E83-3 AND E150-1:&lt;br /&gt;
                        = W1 located left of E2: W1 on left 2&lt;br /&gt;
                          stake-pins, marked with &amp;quot;box&amp;quot;.&lt;br /&gt;
                        = W3 located between E54 and E75: W3 on&lt;br /&gt;
                          horizontal stake-pins, marked with &amp;quot;box&amp;quot;.&lt;br /&gt;
                        = W2 located below junction of E24 and E62:&lt;br /&gt;
                          W2 on left 2 stake-pins marked with &amp;quot;box&amp;quot;.&lt;br /&gt;
                        = W4 located below E24: W4 plugged on left 2&lt;br /&gt;
                          stake-pins marked with &amp;quot;box&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
            SET CIBCA BACKPLANE JUMPER SETTINGS AS FOLLOWS:(FOR QUICK REFERENCE)&lt;br /&gt;
            --------------------------------------------------------------------&lt;br /&gt;
                Refer to CIBCA Users Guide Pg. 2-10 to 2-13&lt;br /&gt;
                All jumpers are located behind T1015 Module.&lt;br /&gt;
                Jumper changes DO NOT take effect until SELF-TEST&lt;br /&gt;
                EXECUTED.&lt;br /&gt;
&lt;br /&gt;
            o &amp;quot;7/10-TICK ALTER-DELTA-TIME&amp;quot; CONTROLLED BY JUMPER ON&lt;br /&gt;
              T1015 BACKPLANE PINS E11-E41, E09-E39, and E10-E40:&lt;br /&gt;
                - ENSURE E09-E39 and E10-E40 JUMPERS &amp;quot;OUT&amp;quot;.&lt;br /&gt;
                - &amp;quot;7 -TICK COMPAT.,  ECO-OFF&amp;quot;: Jumper OUT E11-E41.&lt;br /&gt;
                - &amp;quot;10-TICK INCOMPAT.,ECO-ON&amp;quot; : Jumper IN  E11-E41.&lt;br /&gt;
&lt;br /&gt;
            o CLUSTER-SIZE FOR 16/32-NODE ADDRESSING AND ARBITRATION IS&lt;br /&gt;
              SET BY JUMPER ON T1015 PINS D30-D60 and D29-D59:&lt;br /&gt;
                - Ensure E29-E59 out for both 16 or 32-NODE mode.&lt;br /&gt;
                - 16-NODE mode (default no CISCE): D30-D60 &amp;quot;OUT&amp;quot;.&lt;br /&gt;
                - 32-NODE mode (CISCE 24-NODE   ): D30-D60 &amp;quot;IN&amp;quot; .&lt;br /&gt;
&lt;br /&gt;
        11. Set main power circuit breaker of the CPU cabinet to the&lt;br /&gt;
            ON (1) position.&lt;br /&gt;
&lt;br /&gt;
        12. Set the 877 power controller main power circuit breaker&lt;br /&gt;
            of the expander cabinet containing CI (CIPA) box to the&lt;br /&gt;
            ON (1) position.&lt;br /&gt;
&lt;br /&gt;
        13. Close the rear doors of the CPU cabinet and the expander&lt;br /&gt;
            cabinet containing the CI (CIPA) box.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  10  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
        14. Power on the system by typing &amp;gt;&amp;gt;&amp;gt;PON.&lt;br /&gt;
&lt;br /&gt;
        15. Run the following Level III (offline) diagnostics under the&lt;br /&gt;
            DIAG. SUPV. (DS&amp;gt;) E*SAA-10.8 to verify that the CIXXX is functional.&lt;br /&gt;
&lt;br /&gt;
            DIAGNOSTIC        MINIMUM VERSION              TITLE&lt;br /&gt;
            ----------        ---------------              -----&lt;br /&gt;
              EVGAA                4.1              CI Functional Diag Part  I&lt;br /&gt;
              EVGAB                4.1              CI Functional Diag Part II&lt;br /&gt;
&lt;br /&gt;
            WARNING: EVGAA/B may report &amp;quot;false errors&amp;quot; when connected to &amp;quot;live&amp;quot;&lt;br /&gt;
                     CLUSTER due to receipt of SCS START-DATAGRAMS from VMS.&lt;br /&gt;
&lt;br /&gt;
        16. Remove the loopback attenuators and reconnect the BNCIA cables&lt;br /&gt;
            to their original SC008 ports.&lt;br /&gt;
&lt;br /&gt;
        17. Boot system into VAXcluster, using customer's &amp;quot;standard operating&lt;br /&gt;
            procedures&amp;quot;. IT IS PREFERRED THAT THE CUSTOMER PERFORM THIS STEP.&lt;br /&gt;
&lt;br /&gt;
                EVERY UPGRADED CI/HSC NODE WITH NEW L0100-E*/L0118 SHOULD&lt;br /&gt;
                BE TESTED UNDER VMS IN &amp;quot;7-TICK ECO-OFF MODE&amp;quot; TO SYSTEM-TEST&lt;br /&gt;
                NEW FCO PARTS PRIOR TO CLUSTER-WIDE CI-LINK-MODE TRANSITION.&lt;br /&gt;
&lt;br /&gt;
        18. UPGRADE remaining CI750, CI780, CIBCI, HSC50, &amp;amp; HSC70 nodes&lt;br /&gt;
            that do not contain L0100-E1/E2 or L0118 CI-LINK module.&lt;br /&gt;
&lt;br /&gt;
            *** REPEAT STEP 1 UNTIL ALL NODES ARE COMPLETED. ***&lt;br /&gt;
&lt;br /&gt;
        19. Set all CI/HSC nodes to &amp;quot;10-TICK, INCOMPATIBLE, ECO-ENABLED&lt;br /&gt;
            MODE&amp;quot; operation.  *** THIS REQUIRES ENTIRE CLUSTER-SHUTDOWN&lt;br /&gt;
            TO AVOID CI-PATH FAILURES, CLUSTER-MEMBER LOSS, AND RISKS TO&lt;br /&gt;
            DATA-INTEGRITY.  ***  Ensure each CI is powered off when&lt;br /&gt;
            changing jumpers.&lt;br /&gt;
&lt;br /&gt;
            Set &amp;quot;10-TICK, INCOMPATIBLE, ECO-ENABLED MODE&amp;quot; by referring&lt;br /&gt;
            to Page 7, Step 10;  or use following quick reference chart:&lt;br /&gt;
&lt;br /&gt;
                        L0100-E1   L0100-E2        L0118        CIBCA&lt;br /&gt;
                          E177       SW3-1         SW3-4        T1015&lt;br /&gt;
                         JUMPER     SWITCH         SWITCH       E11-E41&lt;br /&gt;
                        -------     ------         ------       -------&lt;br /&gt;
              7 -TICK:  11-12 IN     &amp;quot;OFF&amp;quot;          &amp;quot;OFF&amp;quot;        &amp;quot;OUT&amp;quot;&lt;br /&gt;
              10-TICK:  9-10  IN     &amp;quot;ON&amp;quot;           &amp;quot;ON&amp;quot;         &amp;quot;IN&amp;quot;&lt;br /&gt;
&lt;br /&gt;
            Only L0100 Rev E* needs to be removed in order to set to 10-TICK.&lt;br /&gt;
&lt;br /&gt;
        20. Boot all systems back into VAXcluster, starting with HSCs, using&lt;br /&gt;
            customer's &amp;quot;standard operating procedures&amp;quot;.  IT IS PREFERRED&lt;br /&gt;
            THAT THE CUSTOMER PERFORM THIS STEP.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  11  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
        21. Report the FCO activity on the LARS form in the &amp;quot;module/fail/area/&lt;br /&gt;
            FCO&amp;quot; column as &amp;quot;FCO CIBCI-I002&amp;quot; as indicated.&lt;br /&gt;
&lt;br /&gt;
        22. Update Site Management Guide.&lt;br /&gt;
&lt;br /&gt;
        ----------------------------------------------------------------------&lt;br /&gt;
                                       LARS&lt;br /&gt;
                                       ----&lt;br /&gt;
&lt;br /&gt;
                                USA              GIA             EUROPE&lt;br /&gt;
&lt;br /&gt;
  Activity -&lt;br /&gt;
     Contract and Warranty      W                U               Y&lt;br /&gt;
     Non Contract/Non Warranty  F                F               F&lt;br /&gt;
  DEC Option                    CIBCI            CIBCI           CIBCI&lt;br /&gt;
  Type of Call                  M                M               M&lt;br /&gt;
  Action Taken                  D                D               I&lt;br /&gt;
  Fail Area-Module-FCO-Comments CIBCI-I002       CIBCI-I002      CIBCI-I002&lt;br /&gt;
  Material Used                 EQ-01454-05      EQ-01454-05     EQ-01454-05&lt;br /&gt;
                                EQ-01454-04      EQ-01454-04     EQ-01454-04&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
                FIGURE 1 - L0118 LINK MODULE SWITCHES&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
      _ _ _ _ _ _ _               |           FCO   CIBCI-I002&lt;br /&gt;
     | | | | | | | |              |&lt;br /&gt;
     |d|i|g|i|t|a|l|              |           PAGE  12  OF  12&lt;br /&gt;
     |_|_|_|_|_|_|_|              |&lt;br /&gt;
                                  |&lt;br /&gt;
   _______________________________|_________________________________________&lt;br /&gt;
&lt;br /&gt;
                FIGURE 2 - L0118 LINK MODULE SETTINGS&lt;br /&gt;
&lt;br /&gt;
\^ CIBCI&lt;br /&gt;
\\CIBCI&lt;br /&gt;
\\BRASSARD&lt;br /&gt;
\\1988&lt;br /&gt;
\\JUN&lt;br /&gt;
\\FCO_DOCS&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category: DEC Documentation]]&lt;/div&gt;</summary>