Both of these devices used a custom [[system unit]] [[backplane]], containing multiple cards; one or more [[flat cable]]s connected this, via a [[Berg connector]] on [[DEC card form factor|single-width]] M791 cards, to the backplane of the separate 5-1/4" high rack-mounted [[DEC card form factor|dual-height]] distribution panel.
+
Both of these devices used a custom [[system unit]] [[backplane]], containing multiple [[printed circuit board|cards]]; one or more [[flat cable]]s connected the device to the separate 5-1/4" high rack-mounted [[DEC card form factor|dual-height]] distribution panel, via a [[Berg connector]] on single-width M791 cards plugged into the panel's backplane.
  
Modular 'line conditioning' units were installed in the distribution panel's backplane, to allow support of either [[20mA current loop serial line interface|20mA]] serial lines (local only), or [[EIA RS-232 serial line interface|EIA RS-232]] serial lines (local or modems - modems usually required a [[DM11-BB Modem Control Option]] as well as the basic asynchronous serial line interface).
+
Modular 'line conditioning' units were installed in the panel's backplane, to allow support of either [[20mA current loop serial line interface|20mA]] serial lines (local only), or [[EIA RS-232 serial line interface|EIA RS-232]] serial lines (local or modems - modems usually required a [[DM11-BB Modem Control Option]] as well as the basic asynchronous serial line interface).
  
 
==Line conditioning==
 
==Line conditioning==
 
[[Image:M594.jpg|250px|thumb|right|M594 TTL to EIA Level Converter]]
 
  
 
Three broad choice were available for line conditioning:
 
Three broad choice were available for line conditioning:
Line 16: Line 14:
 
* Use the DM11-DA (20mA line conditioning) or DM11-DB (EIA, no modem control), each of which supported four lines; thus, with these, line conditioning could be mixed in groups of four.
 
* Use the DM11-DA (20mA line conditioning) or DM11-DB (EIA, no modem control), each of which supported four lines; thus, with these, line conditioning could be mixed in groups of four.
 
* Use the DM11-DC (EIA, modem control), each card of which also supported only one line.
 
* Use the DM11-DC (EIA, modem control), each card of which also supported only one line.
 +
 +
[[Image:M5960.jpg|250px|thumb|right|M5960 TTL to 20mA Level Converter]]
  
 
The DM11-DA included:
 
The DM11-DA included:
Line 22: Line 22:
 
** The M5960 was a later version of this card
 
** The M5960 was a later version of this card
 
* M973 - Mate-N-Lok header (4 per M596)
 
* M973 - Mate-N-Lok header (4 per M596)
 +
 +
[[Image:M973.jpg|250px|thumb|right|M973 20mA Mate-N-Lok header card]]
  
 
and in the DM11-DB:
 
and in the DM11-DB:
Line 29: Line 31:
 
* BC01R cables (4 per, probably attached to an M957 or M970 card)
 
* BC01R cables (4 per, probably attached to an M957 or M970 card)
  
Note that these are all DF11 cards; however, they were plugged into different slots in the DM11 distribution panel backplane from those used by cards used for single lines. (There were slots at the ends of the distribution panel's backplane into which the 4-line cards plugged; a group of 16 slots in the middle could hold the DF11's or DM11-DC's.)
+
[[Image:M594.jpg|250px|thumb|right|M594 TTL to EIA Level Converter]]
 +
 
 +
Note that these two were both DF11 cards; however, they were plugged into different slots in the DM11 distribution panel backplane from those used by cards used for single lines. (There were separate slots at the ends of the distribution panel's backplane into which the 4-line cards plugged; a group of 16 slots in the middle could hold the DF11's or DM11-DC's.)
 +
 
 +
[[Image:M970.jpg|250px|thumb|right|M970 EIA Berg header card]]
  
 
The DM11-DC consisted of four M594s and cables, plugged into individual line slots.
 
The DM11-DC consisted of four M594s and cables, plugged into individual line slots.
  
 
[[Category: UNIBUS Serial Interfaces]]
 
[[Category: UNIBUS Serial Interfaces]]

Revision as of 21:28, 4 March 2020

The DM11 distribution panel (formally, the DM11-AA distribution panel) was used with the DM11 and early models of the DH11 interfaces, to connect these interfaces to asynchronous serial lines which used a number of different low-level electrical interface specifications, and connected either to local terminals, or to modems.

M791 connector card

Both of these devices used a custom system unit backplane, containing multiple cards; one or more flat cables connected the device to the separate 5-1/4" high rack-mounted dual-height distribution panel, via a Berg connector on single-width M791 cards plugged into the panel's backplane.

Modular 'line conditioning' units were installed in the panel's backplane, to allow support of either 20mA serial lines (local only), or EIA RS-232 serial lines (local or modems - modems usually required a DM11-BB Modem Control Option as well as the basic asynchronous serial line interface).

Line conditioning

Three broad choice were available for line conditioning:

  • Use any unit from the DF11 Communications Line Adapter series, each of which only supported a single line.
  • Use the DM11-DA (20mA line conditioning) or DM11-DB (EIA, no modem control), each of which supported four lines; thus, with these, line conditioning could be mixed in groups of four.
  • Use the DM11-DC (EIA, modem control), each card of which also supported only one line.
M5960 TTL to 20mA Level Converter

The DM11-DA included:

  • M596 - TTL to 20mA Level Converter
    • The M5960 was a later version of this card
  • M973 - Mate-N-Lok header (4 per M596)
M973 20mA Mate-N-Lok header card

and in the DM11-DB:

  • M594 - TTL to EIA Level Converter
  • W404 - DTR Jumper card (4 per M594)
  • BC01R cables (4 per, probably attached to an M957 or M970 card)
M594 TTL to EIA Level Converter

Note that these two were both DF11 cards; however, they were plugged into different slots in the DM11 distribution panel backplane from those used by cards used for single lines. (There were separate slots at the ends of the distribution panel's backplane into which the 4-line cards plugged; a group of 16 slots in the middle could hold the DF11's or DM11-DC's.)

M970 EIA Berg header card

The DM11-DC consisted of four M594s and cables, plugged into individual line slots.