Difference between revisions of "RH70 MASSBUS controller"

From Computer History Wiki
Jump to: navigation, search
(+cat)
(cache controls main mem bus access)
Line 3: Line 3:
 
One the -11/70 side, it contains connections to both the -11/70's [[main memory]] and [[cache]] (for data reads and writes from the device), as well as to the [[UNIBUS]] (for [[interrupt]]s, and access to the device's [[register]]s by the [[Central Processing Unit|CPU]]).
 
One the -11/70 side, it contains connections to both the -11/70's [[main memory]] and [[cache]] (for data reads and writes from the device), as well as to the [[UNIBUS]] (for [[interrupt]]s, and access to the device's [[register]]s by the [[Central Processing Unit|CPU]]).
  
The connection to the cache is purely for data transfer control purposes; all data reads and writes go directly to the actual main memory. A write to a main memory location which is stored in the cache invalidates that cache entry.
+
The connection to the cache is purely for data transfer control purposes; all data reads and writes go directly to the actual main memory (although the RH70's access to the main memory bus is controlled by the cache). A write to a main memory location which is stored in the cache invalidates that cache entry.
  
 
==Hardware==
 
==Hardware==

Revision as of 15:14, 27 April 2021

The RH70 MASSBUS controller allowed the interconnection of MASSBUS devices such as the RP04 to a PDP-11/70.

One the -11/70 side, it contains connections to both the -11/70's main memory and cache (for data reads and writes from the device), as well as to the UNIBUS (for interrupts, and access to the device's registers by the CPU).

The connection to the cache is purely for data transfer control purposes; all data reads and writes go directly to the actual main memory (although the RH70's access to the main memory bus is controlled by the cache). A write to a main memory location which is stored in the cache invalidates that cache entry.

Hardware

Each RH70 (up to a maximum of 4) consisted of a special pre-wired 4-slot section of the CPU's backplane, into which plugged a number of cards:

One hex-sized:

  • M8150 - MDP - Data buffer and parity

Three quad-sized:

  • M8151 - CST - Control and Status
  • M8152 - AWR - Address and Word Count registers
  • M8152 - BCT - bus control

Three dual-height M5904 MASSBUS transceiver modules.

Registers

The RH70 contains 6 registers, plus a share of a seventh; they are

  • RHCS1 - Control and Status 1 (shared)
  • RHWC - Word Count
  • RHBA - Bus Address
  • RHBAE - Bus Address Extension
  • RHCS2 - Control and Status 2
  • RHCS3 - Control and Status 3
  • RHDB - Data Buffer (for maintenance)

As is standard for the MASSBUS, all the other device registers are in the device.