Search results

From Computer History Wiki
Jump to: navigation, search
  • ...d at 960 characters per second. Thus [[flow control]] was essential unless working with a slow system (e.g. an old [[minicomputer]]..). Xon/Xoff was the most ...al/vt100/MP00633_VT100_Schematic_Feb82.pdf VT100-0 Field Maintenance Print Set] - schematics
    4 KB (664 words) - 14:34, 11 August 2023
  • *A working copy of bzip2 set rq dis
    6 KB (1,042 words) - 22:50, 1 May 2022
  • If you are set up to do it, it is a good idea immediately to make a copy of the tape to *The DZ11 driver is set to run 8 lines. This can be changed in dz.c
    24 KB (3,883 words) - 10:33, 6 March 2023
  • three ROMs, but can be upgraded just by inserting the proper set of chips. ...he manual, it mentions that the A2090a SCSIdirect implementation is almost working. @{"16. German Connection " link 16}
    136 KB (31,870 words) - 21:08, 14 January 2024
  • at least 250 blocks of free space for working storage. set cpu 32K
    2 KB (265 words) - 19:20, 27 December 2023
  • If you are set up to do it, it is a good idea immediately to make a copy of the tape to gu The disk and tape drivers for the MASSBUS devices (hp.c, ht.c) are set up to run 1 drive and should be changed if you have more.
    42 KB (6,834 words) - 03:01, 17 January 2023
  • set cpu 256k Then to build the Fortran test program to verify your kit is working:
    3 KB (544 words) - 17:57, 11 October 2009
  • multi volume set to start on. This allows restor to be Mount volume 1 of the set of dump tapes.
    3 KB (654 words) - 23:47, 4 January 2010
  • tially set to the line and file containing the source state- they are set to the first line in main. The current line
    8 KB (1,218 words) - 17:40, 26 October 2009
  • ...B and -JC are earlier versions, which contain an error which prevents them working properly as QBUS memories (i.e. in the PDP-11/83); they are only usable in ...modified by the CPU are shown in normal font, and those which can also be set by the [[hardware]] in ''italics''.
    8 KB (1,374 words) - 00:43, 30 July 2023
  • *A working perl interpeter to make the tape images.<br> set rq0 ra81
    14 KB (2,267 words) - 16:59, 5 April 2010
  • *A working perl interpeter to make the tape images.<br> set rq0 dis
    15 KB (2,380 words) - 18:46, 28 October 2020
  • *A working copy of gunzip ...distribution files and patches can be fetched with ftp. To facilitate this set up an anon ftpd that serves up the files. It should be possible to obtain t
    27 KB (4,355 words) - 23:38, 26 March 2023
  • set cpu 256k set rq0 rx50
    11 KB (2,002 words) - 21:04, 20 November 2023
  • The '''Interdata 8/32''' was a 32-bit [[supermini]] whose [[instruction set architecture|ISA]] was roughly modelled on that of the [[IBM System/360]] [ ...ine itself was delivered at the end of April 1977. By June, the system was working reasonably well.
    2 KB (289 words) - 18:25, 22 December 2023
  • - A complete set of compiler writing tools people are currently working on
    5 KB (803 words) - 01:20, 20 December 2018
  • - A complete set of compiler writing tools gaps in the present implementation. Various people are currently working
    5 KB (824 words) - 01:26, 20 December 2018
  • - A complete set of compiler writing tools gaps in the present implementation. Various people are currently working
    6 KB (879 words) - 01:25, 20 December 2018
  • nighters to get a nifty program working? Then this post might be just As I mentioned a month(?) ago, I'm working on a free version of a
    4 KB (647 words) - 01:24, 20 December 2018
  • If you are set up to do it, it might be a good idea The DC11 driver is set to run 4 lines. This can be
    27 KB (4,414 words) - 02:56, 17 January 2023
  • _ Working operators in C; here is the complete set:
    71 KB (8,839 words) - 02:18, 17 December 2018
  • or not. I had hoped that through the groups I was working of 1990, the UCB CSRG staff seriously began to set their
    25 KB (3,920 words) - 05:43, 15 July 2019
  • ...physical NT 3.1 CD with WIN32 SDK, and Qemu 0.10.5 which will allow me to set my cpu to an Intel Pentium CPU so I won't have to worry about the inf files ...latest version of Qemu (and I think all of the 12.x line) do *NOT* have a working ISAMACHINE mode for some reason. However for the sake of NT 3.1, I've been
    6 KB (997 words) - 11:22, 9 June 2023
  • ...project was far from the top of the list of projects I was supposed to be working on and I just never got it going again. 230-and M is the save set number (from 1 to 3 but usually 1).
    6 KB (1,036 words) - 19:49, 13 January 2024
  • * You will need a working copy of SIMH's vax780.exe for your platform. set tto 7b
    5 KB (848 words) - 07:12, 2 February 2016
  • If you are set up to do it, it is a good idea immedi- #date yymmddhhmm (set date, see date(1))
    57 KB (8,582 words) - 03:00, 17 January 2023
  • mand it should rather use the set command: ``set loader option from having breakpoints set on them
    39 KB (5,307 words) - 05:01, 11 December 2018
  • You know your application needs; we know our products. Working together we 1.1.4 Part IV ÄÄ Instruction Set
    890 KB (107,817 words) - 03:20, 3 January 2024
  • * Get simh working (out of scope) * To get text out of your installation without having to set up KERMIT provide an entry point for simh to print to
    8 KB (1,219 words) - 00:21, 11 June 2012
  • telephones required a standard; until that standard was set, your support infrastructure grew, and as people's ways of working adapted to
    627 KB (92,395 words) - 03:42, 17 December 2018
  • set cpu 11/70 set cpu 2M
    6 KB (835 words) - 13:57, 29 May 2020
  • set CPU 64m set CPU conhalt
    44 KB (6,192 words) - 09:30, 29 September 2023
  • * You will need a working copy of SIMH's vax780.exe for your platform. set tto 7b
    7 KB (1,100 words) - 07:32, 2 February 2016
  • *A working zip tool to extract .zip files set rq0 ra81
    13 KB (2,077 words) - 16:30, 7 August 2017
  • The J-11 chip set includes microcode which provides '[[front panel]]' functionality named '[[ ...t 'oscilliscope loops', either to debug a memory card when there isn't any working memory plugged in, or when there is a desire to avoid 'contaminating' the b
    3 KB (457 words) - 14:32, 21 February 2023
  • ...m to be built more easily (as only the lowest-level sub-systems need to be working at first), and more easily understood (since most of the higher-layered sub * [[Instruction set architecture]]
    3 KB (488 words) - 00:30, 23 October 2023
  • ...st identical [[instruction set]]s; Honeywell added an Extended Instruction Set (EIS) which provided string-manipulation instructions, [[binary-coded decim ...sed to produce a more secure system, using [[domain]] ideas and '[[working set]]s'; and also [[virtual memory]] (which the GCOS machines had not previousl
    12 KB (1,837 words) - 19:24, 3 January 2024
  • ...lly, a few mission-critical sites which did not have their TCP/IP software working yet could get ''temporary'' 'stays of execution', but basically NCP was tur ...id not appear in messages; instead, links were used. When a connection was set up, between one host/socket to another, it used a particular link, specifie
    4 KB (622 words) - 03:45, 17 July 2022
  • ...ory|memory]] [[printed circuit board|boards]] where the board is basically working, but just has some failing [[bit]]s. The first step in working with one of them, without a circuit diagram, is to create a table which tra
    5 KB (971 words) - 14:05, 18 October 2020
  • ...d' on V6 systems (either real, or simulated), which is very convenient for working on them. The maximum file size supported is 1MB (512*256*8 = 1,048,576 byte ...ng language|C]] [[compiler]], which generate [[PDP-11 Extended Instruction Set|EIS]] instructions. On PDP-11 CPU models which do not support the EIS, an [
    8 KB (1,243 words) - 21:16, 21 June 2023
  • The '''Interdata 7/32''' was a 32-bit [[supermini]] whose [[instruction set architecture|ISA]] was roughly modelled on that of the [[IBM System/360]] [ ...in anticipation of the delivery of their machine in April and had a kernel working by June less than two months after the Wollongong kernel first ran on the b
    2 KB (286 words) - 18:26, 22 December 2023
  • The '''Packet Radio Network''' was a program set up by [[DARPA]] in 1973 to explore the possibility of an ad-hoc [[data netw * M. Beeler, ''SPP Definition'', PRTN No. 177, ARPA Packet Radio Network working document, April 1976
    4 KB (557 words) - 20:49, 29 January 2024
  • You cannot set a memory size smaller than 1MB in the simh vax780 simulator directly, but t You set the maximum available memory in '''SYSBOOT>''' on the first boot.
    14 KB (1,788 words) - 03:29, 13 December 2022
  • $ SET DEF <SYSUPD> $ SET DEF <SYSEXE>
    15 KB (1,849 words) - 16:06, 20 September 2022
  • which are compatible with each other and a given set of VMS and The System ID Register bits are set from jumpers on the KA780
    70 KB (7,782 words) - 14:04, 2 July 2022
  • SET QUIET SET CPU MODEL=785
    73 KB (9,059 words) - 20:56, 22 May 2023
  • To set up the [[ULTRIX Remote Installation Service]] (RIS) you need some preparati ip link set br0 up
    32 KB (4,724 words) - 22:56, 7 July 2022
  • SET QUIET SET CPU MODEL=MicroVAX
    80 KB (9,795 words) - 09:39, 10 July 2022
  • * You own a [[MicroVAX]] or [[VAXstation]] without a working disk SET QUIET
    112 KB (13,727 words) - 18:09, 30 January 2024
  • ...of 20 three ring binders was considered acceptable; now, the documentation set was larger than the machine itself. Previously, VAX/VMS systems were instal ...price. How could the value of software to the user be measured in order to set a price? CPU capacity became only a small part of the measure of the useful
    21 KB (3,330 words) - 03:40, 16 January 2024

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)