Difference between revisions of "MH10 core memory"

From Computer History Wiki
Jump to: navigation, search
(big-endian numbering, 18/22 config, bank enable/dis)
m (External links: +Manual, FMPS)
Line 12: Line 12:
  
 
* [[MG10 core memory]]
 
* [[MG10 core memory]]
 +
 +
==External links==
 +
 +
* [http://www.bitsavers.org/pdf/dec/pdp10/memory/EK-MH10-MM-003_MH10_Maint_Aug77.pdf MH10 Maintenance Manual] (EK-MH10-MM-003)
 +
* [http://www.bitsavers.org/pdf/dec/pdp10/memory/MP00178_MH10_Schematic_Aug76.pdf MH10 Field Maintenance Print Set] (MP00178)
  
 
[[Category: PDP-10 memories]]
 
[[Category: PDP-10 memories]]

Revision as of 20:53, 17 October 2021

The MH10 was a core main memory system for the PDP-10s, principally the KI10 and early KL10s. An MH10 could contain up to four 64KW memory banks*, for a maximum of 256KW (only 1, 2 or 4 bank operation is supported, however). The access time is .74 µseconds, and the cycle time is 1.18 µseconds; parity is provided to protect the memory contents. An MH10 contains a pair of 'controllers', with the controller used for any particular cycle selected by address bit 20.

It was a multi-port memory, with 8 ports per memory system: the CPU uses one port (in a multi-processor system, one per CPU); the others are used by channels (such as a DF10) for mass storage such as disks.

It connected to the so-called external memory bus of the KA (18-bit address) or KI (22-bit address) form. Each port could be independently set to use 18- or 22-bit addresses, or to be disabled. Banks could also be independently enabled/disabled. The base address of an MH10 is switch-selectable; that address is used on all the ports, unlike the earlier PDP-10 memories.

The MH10 supports two-way interleaving internally to an MH10, and four-way interleaving between a pair of MH10's (provided they are equally sized); any interleaving applies to all ports. For the two-way case, address bits 20 and 35 are exchanged (recall that the PDP-10 uses big-endian numbering, so bit 35 is the low-order bit), so that all even addresses are handled by controller 0, and odd by controller 1.

* - DEC documentation conflicts on this; the 'MH10 Maintenance Manual', EK-MH10-MM-003, August 1977, says optionally four 64KW banks (pg. 1-1) - and has generally been followed for this writeup; the 'DECsystem-10 DECSYSTEM-20 Processor Reference Manual', AA-H391A-TK, July 1980, says two 128KW banks (pg. G-18).

See also

External links