The bus was connected using 3-pin AMP MATE-N-LOK connectors: all units with a remote control input used a male shell (with female sockets); all the cables (normally 3-conductor, #22 gauge, but 2-conductor is seen, as on the right) had female shells (with male pins), on both ends. | The bus was connected using 3-pin AMP MATE-N-LOK connectors: all units with a remote control input used a male shell (with female sockets); all the cables (normally 3-conductor, #22 gauge, but 2-conductor is seen, as on the right) had female shells (with male pins), on both ends. | ||
− | The male shell (housing) was a 1-480304-0, and took 61173-1 sockets (i.e. female pins); the female shell was a 1-480305-0, and took 61174-1 | + | The male shell (housing) was a 1-480304-0, and took 61173-1 sockets (i.e. female pins); the female shell was a 1-480305-0, and took 61174-1 male pins. (There are a large number of different pin options: 30-22, 24-18, and 20-14 gauge; tin and gold plated; and brass and phosphor-bronze material. The part numbers given are for tinned brass, 30-22 gauge.) |
AMP has been bought by TE Connectivity, but these MATE-N-LOK connectors are still in production, and available from the usual suppliers. | AMP has been bought by TE Connectivity, but these MATE-N-LOK connectors are still in production, and available from the usual suppliers. | ||
− | [[Category: DEC | + | [[Category: DEC Electrical]] |
Latest revision as of 18:50, 15 June 2022
The Remote Switching Control Bus was a power control bus used across many DEC product lines to allow remote control of power. It contained three lines: a ground return, a 'power on', and an 'emergency shutdown'. (Not all devices used the last, e.g. the illustrated example below.)
The bus was connected using 3-pin AMP MATE-N-LOK connectors: all units with a remote control input used a male shell (with female sockets); all the cables (normally 3-conductor, #22 gauge, but 2-conductor is seen, as on the right) had female shells (with male pins), on both ends.
The male shell (housing) was a 1-480304-0, and took 61173-1 sockets (i.e. female pins); the female shell was a 1-480305-0, and took 61174-1 male pins. (There are a large number of different pin options: 30-22, 24-18, and 20-14 gauge; tin and gold plated; and brass and phosphor-bronze material. The part numbers given are for tinned brass, 30-22 gauge.)
AMP has been bought by TE Connectivity, but these MATE-N-LOK connectors are still in production, and available from the usual suppliers.