Line 31: Line 31:
 
}}
 
}}
  
== MicroVAX 2000 Options ==
+
== MicroVAX 2000 Parts & Options ==
 +
 
 +
=== Power Supply ===
 +
 
 +
* [[H7848 Power Supply]]
 +
* 54-17163 Resistor Load Module Option
  
 
=== Memory Options ===
 
=== Memory Options ===
Line 47: Line 52:
 
* [[DST32 Synchronous Serial Line Option]] [[#ref_7|[7]]]
 
* [[DST32 Synchronous Serial Line Option]] [[#ref_7|[7]]]
 
* [[DESVA VAXstation 2000 / MicroVAX 2000 ThinWire Ethernet Option]] [[#ref_2|[2]]]
 
* [[DESVA VAXstation 2000 / MicroVAX 2000 ThinWire Ethernet Option]] [[#ref_2|[2]]]
 +
 +
=== Expansion Boxes ===
 +
 +
* [[BA40A Expansion Adapter]]
 +
* [[TK50Z-F Tape Expansion Box]]
 +
* [[RD53-F Disk Expansion Box]]
 +
* [[RD54-F Disk Expansion Box]]
 +
 +
You need the BA40A expansion adapter to connect any of the expansion boxes.
 +
 +
The expansion box houses either a tape drive or a fixed disk drive and is shipped with a drive cable.
 +
The drive cable connects the expansion box to the MicroVAX 2000 / VAXstation 2000 system unit's expansion adapter.
 +
The expansion adapter must already be installed on the bottom of the MicroVAX 2000 / VAXstation 2000 system unit before the expansion box is connected.
 +
 +
You may install a total of two expansion boxes (one with a fixed disk and one with a tape drive).
 +
If you are installing more than one expansion box, first install the expansion box with the tape drive, and then install the expansion box with the fixed disk.
  
 
== References ==
 
== References ==

Revision as of 09:59, 12 August 2022

MicroVAX 2000 Systems

MicroVAX 2000
Summary
Codename: Teammate
OS support (VMS): V4.5B
CPU Details
CPU name (VMS): KA410
CPU name (console): KA410-A
CPU module: KA410
Number of processors: 1
VMS DCL CPU: 8
VMS DCL XCPU: 4
SID: 08000000
XSID: 04040001
CPU chip: DC333
FPU chip: DC337 [2]
CPU technology: ZMOS
CPU cycle time: 200ns [2]
CPU clock: 40MHz [2]
Instruction-buffer: 8 bytes [3]
Cache: None
Memory
Minimum memory: 2MB [2]
Maximum memory: 16MB [2]
Physical address lines: 30 [2]
Memory checking: Byte parity [2]
On-board memory: 2MB [2]
I/O
Max I/O throughput: 3.3MB/s
LAN support: Optional: DESVA ThinWire Ethernet Option
Performance
VUPs: 0.9


MicroVAX 2000 Parts & Options

Power Supply

Memory Options

Only one MS400 memory module may be connected to a KA410-A system module, which has 2MB on-board memory.

Communication Options

Expansion Boxes

You need the BA40A expansion adapter to connect any of the expansion boxes.

The expansion box houses either a tape drive or a fixed disk drive and is shipped with a drive cable. The drive cable connects the expansion box to the MicroVAX 2000 / VAXstation 2000 system unit's expansion adapter. The expansion adapter must already be installed on the bottom of the MicroVAX 2000 / VAXstation 2000 system unit before the expansion box is connected.

You may install a total of two expansion boxes (one with a fixed disk and one with a tape drive). If you are installing more than one expansion box, first install the expansion box with the tape drive, and then install the expansion box with the fixed disk.

References

[1] VAXstation 2000 System Guide. EK-V2000-SG-001
[2] VAXstation 2000 and MicroVAX 2000 Technical Manual. EK-VTTAA-TM.001
[3] MicroVAX Systems Handbook 1988. EB-30991-41
[4] Systems & Options Catalog. European Edition. Spring 1990.
[5] MicroVAX 2000 Installation Guide Addendum - DHT32 Asynchronous Serial Line Option. EK-ASYSL-IN-001
[6] Preliminary DSH32 Synchronous-Asynchronous Serial Line Option. EK-283AA-AD-001
[7] MicroVAX 2000 Installation Guide Addendum - DST32 Synchronous Serial Line Option. EK-SYNCH-IN-001