Difference between revisions of "DF10 Data Channel"
m (→External links: +later MM) |
m (→External links: +DEC-10-XSRMA-A-D) |
||
Line 33: | Line 33: | ||
* [http://bitsavers.org/pdf/dec/pdp10/periph/A-MN-DF10-C_MAN1_DF10-C_Data_Channel_Maintenance_Manual_Oct74.pdf DF10-C Data Channel Maintenance Manual] (A-MN-DF10-C_MAN1) | * [http://bitsavers.org/pdf/dec/pdp10/periph/A-MN-DF10-C_MAN1_DF10-C_Data_Channel_Maintenance_Manual_Oct74.pdf DF10-C Data Channel Maintenance Manual] (A-MN-DF10-C_MAN1) | ||
* [http://bitsavers.org/pdf/dec/pdp10/periph/DF10_Engineering_Drawings.pdf DF10 Engineering Drawings] | * [http://bitsavers.org/pdf/dec/pdp10/periph/DF10_Engineering_Drawings.pdf DF10 Engineering Drawings] | ||
+ | * [http://bitsavers.org/www.computer.museum.uq.edu.au/pdf/DEC-10-XSRMA-A-D%20DECsystem10%20System%20Reference%20Manual.pdf DECsystem-10 System Reference Manual] - documents the DF10 in section 5-1 (pp. 183-188 of the PDF) | ||
[[Category: PDP-10s]] | [[Category: PDP-10s]] |
Revision as of 20:45, 23 September 2022
The DF10 Data Channel is a channel for the early PDP-10 models (KA10 and KI10) which had the PDP-10 main memory bus as a standard bus. It can connect to multi-port memory banks either directly, or via an MX10 Memory Data Multiplexor. It is also connected indirectly (through the device controllers which attach to it) to the system's I/O bus, to allow the CPU to control it.
It has limited capabilities, compared to most channels from other manufacturers: it supports only the following types of channel command words:
- End of program
- Jump to new CCW list
- Discard data
- Transfer data to/from memory
It is used with device controllers such as the RP10 disk controller, TM10 Magnetic Tape Control, and RH10 MASSBUS controller.
Models
- DF10
Introduced 1968 for use with the KA10. Control words have a negated 18-bit word count in the left half, and an 18-bit memory address in the right half.
- DF10-C
Introduced for use with the KI10. The memory address is expanded to 22 bits, and the control word is reduced to 14 bits.
- MIT modified DF10
Used on the Project MAC KA10 DM and ML machines running ITS. The control word has the negated word count in bits 3-17, and the 21-bit memory address is split with bits 15-17 inverted in control bits 0-2, and bits 18-35 in the right half of the control word.
External links
- DF10 Data Channel Maintenance Manual (DEC-10-I8BA-D)
- DF10 Data Channel Maintenance Manual (DEC-10-I8BB-D)
- DF10 Data Channel Maintenance Manual (DEC-10-HDFC-D)
- DF10-C Data Channel Maintenance Manual (A-MN-DF10-C_MAN1)
- DF10 Engineering Drawings
- DECsystem-10 System Reference Manual - documents the DF10 in section 5-1 (pp. 183-188 of the PDF)