Random notes from running the firmware in an emulator.

Memory map

Vs100-memory-map.png

Error LEDs

Indicates which test failed. During power-up, green light turned off. During idle loop, green light remains on.

Vs100-diagnostic-led-errors.png

Apparently there's a bug.

VS100-TT-7.png

Interrupts

All VS100 interrupts use the autovector feature.

VS100-interrupts.png

Keyboard test

The firmware transmits code FD (hex) to the LK201 keyboard, which commands it to jump to the power-up sequence and self-test. The keyboard transmits a four-byte message back. The VS100 ignores the keyboard ID, and checks that the third is not 3D.

This information is from the VT220 Technical Manual.
LK201-powerup.png

D0 flags

The firmware maintains a set of flags in register D0.

Bit (decimal) Meaning
16 Manufacturing mode.
17 BBA present.
18  ?
19 Power-up error.
20 LEDs locked.
22 In maintenance menu.
23 Keyboard ok.
24 BBA done.
25 Vertical retrace interrupt.