Difference between revisions of "FCO CIBCI-I002"
From Computer History Wiki
(New page for CIBCI FCO #2) |
(No difference)
|
Latest revision as of 08:22, 27 February 2023
_ FCO CIBCI-I002, Clusters of 6 or more CI/HSC nodes on SC008 +-----------------------------------------------------------------------------+ | | | _ _ _ _ _ _ _ Level of Urgency Page_1_ | || | | | | | | | +--+ Of_12 | ||d|i|g|i|t|a|l| FCO | I| | ||_|_|_|_|_|_|_| +--+ | |_____________________________________________________________________________| | | | FIELD CHANGE ORDER Number: CIBCI-I002 | |_____________________________________________________________________________| | Applicability: The L0118 Rev B* module should be installed on all CI750, | | CI780, CIBCI, & HSCxx nodes used in VAXclusters of 6 (six) or more CI/HSC | | nodes connected to a common SC008 Star Coupler. L0118s should replace all | | L0100 Rev D* link modules; L0100 Rev E* can coexist with L0118s except in | | greater than 16 node environment. | |_____________________________________________________________________________| | Problem/Symptom: Clusters of 6 or more CI/HSC nodes on SC008 may exhibit | | CI-PATH NO_RSP or NAK, ARB-TIMEOUTS, and VC-CLOSURE. L0118 (& L0100 Rev E*)| | corrects adjacent-node collision & arb problems. * FIX DETAILS ON PAGE 2. * | |_____________________________________________________________________________| | Quick Check: Check that link module is part number L0118. | | | | | |_____________________________________________________________________________| | Compatibility/Prerequisite FCO: | Est. Time to Install: | | CI750-I005, CI780-I006, HSC50-I009,HSC70-I001 | 1 hour per node | |___________________________________________________|_________________________| | Special Tools or Test Equipment: See page 2. | | | |_____________________________________________________________________________| | FCO Parts Information | |_____________________________________________________________________________| | Order by Quantity: Part Number: Description: | | FCO Kit#: | | EQ-01454-05 1 L0118 (Rev B) Link Module | | EQ-01454-04 1 FA-04740-01/05 | | FA-04740-03 1 FCO Document | |_____________________________________________________________________________| |EQ Kit Variation System/Option Applic: N/A | |_____________________________________________________________________________| | Approvals | |_____________________________________________________________________________| | CSSE Engineer | F.S. Product Safety | F.S. Logistics | | Bob Brassard | Robert Brister | Ed Duggan | |____________________|__________________________|_____________________________| | CSSE Manager | F.S. Microfiche Libraries| Affected Population: | | Jan Sicard | | 12,000/2,000 | |____________________| EP-FSNVX-LB VAX |---------------------------- | | MicroMedia Pub. | | Initial Kitting: | | Ray LeBlanc | VAXnotes | 12,000/2,000 | |____________________| STARS |____________________________ | | Revision: | | Hardcopy Publication: | | A | | 2,000 | |____________________| |_____________________________| | FCO Release Date | | Parts Availability: | | 2-JUN-88 | | May 1988 | +-----------------------------------------------------------------------------+ _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 2 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ PROBLEMS/SYMPTOMS: Continued from Page 1. ----------------------------------------- SOLUTION SUMMARY - L0118 DESIGN AND L0100 E* ECOS # - Denotes changes incompatible with L0100-D1, or CIBCA "7-tick DELTA-TIME mode; and controlled by "COMPATIBILITY 7/10-tick" switch on L0100-E1/E2 or L0118. 1.# BASIC QUIET-SLOT extended from 7 to 10 ticks (tick=byte=114 ns., change = 800 ns. to 1140 ns.) to fix adjacent node collision problem at 40% CI-path utilization caused by L0100 Tx-start/Rx- detect logic delays when such nodes simultaneously arbitrate. 2.# HIGH/LOW-PRIORITY (Round-ROBIN) ARBITRATION COUNTER logic fixed to prevent "false BEATEN-BY-NODE-0" detection during ACK- TURNAROUND carrier-delay, resulting in biasing arb-wins to low-nodes. Fix requires QUIET-SLOT change, and must be applied to all L0100 to prevent arbitration biasing. 3. # EXTEND ACK-TURNAROUND TIME (INFO-to-ACK PACKET delay) to ensure CI-sender (INFO-PKT) ready to receive ACK, under worst-case (short,fast) propagation delays, such as with SC004 (dual-CI750) and short-CI-cables (6-10 meter). Fix requires QUIET-SLOT change. 4. Fix SYNC-DETECT "PAL" to prevent lock-up during CI-carrier "flood", an infrequent CI-LINK failure mode. 5. EXTEND "TRAILER TRANSMIT TIME" to ensure at least 5 bytes of trailer (after CRC) sent, instead of 3.5 bytes. 6. EXTEND HEADER JUMPER (not used in current CI applic.) was non-functional: Fix. 7. ALTER-DELTA-TIME JUMPER (7/16-tick quiet-slot) was non-functional: Fix. Not currently used, but intended for extended CI-cabling lengths, or fiber. 8. ARBITRATION STATUS REPORTING enhanced to distinguish ARB-TIMEOUT from "fail to xmit after successful ARB". 9. CI20 ONLY: CRC-COUNT RESET failed on SELF-DIRECTED packets: Fix. 10. MISCELLANEOUS L0100 Print-Set logic-drawing clean-up, marginal logic-design improvement, for benefit of future CIxxx chip-designs (CIBCA...) based on L0100. SPECIAL TOOLS: Continued from page 1. -------------------------------------- Field Service Tool Kit VELOSTAT Electrostatic Field Service Kit (P/N 29-26246-00) Loopback Attenuators (12-19907-01) _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 3 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ PARTS LIST: Continued from page 1. ---------------------------------- Order by Quantity: Part Number: Description: FCO Kit#: EQ-01454-05 1 L0118 (Rev B1/B2) Link Module FA-04740-06 1 Inst. sheet for ordering kits EQ-01454-04 1 FA-04740-01 CI750 FCO Doc. 1 FA-04740-02 CI780 FCO Doc. 1 FA-04740-03 CIBCI FCO Doc. 1 FA-04740-04 HSC50 FCO Doc. 1 FA-04740-05 HSC70 FCO Doc. CIBCI OPTION LEVEL REVISION CHART --------------------------------- CIBCI A1 B1 -------------------------------------------------------------- L0100** D1,(B2*) D,(B2*)E L0118** B1,B2 L0101 H1 J1,K1 L0400 B1,C1 B1,C1 T1017 B1 C1,D1 T1018 B1 C1 Microcode CI780.BIN Rev 5.0 Rev 7,8 BACKPLANE B1,C1 B1,C1 POWER SUPPLY A A --------------------------------------------------------------- * (NOTE) "B2" is being marked on "B" etch and is equal to "D1". **(NOTE) L0118 is enhanced L0100 replacement and can be used as "universal spare". L0118 is required to support >16 node functionality. _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 4 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ LINK MODULE UTILIZATION/SWITCH SETTINGS MATRIX ---------------------------------------------- -------------------------------------------------------------------- | | 1 - 5 NODES | 6 - 16 NODES | | OPTION |-----------------------|-------------------------| | | MODULE/REV/SLOT-COUNT | MODULE/REV/SLOT-COUNT | |----------------|-----------------------|-------------------------| | CI7XX, CIBCI, | L0100 REV "D" | L0100 REV E @ 10 TICK | | HSCXX | L0100 REV "E" @ 7 TICK| | | | L0118 @ 7 TICK | L0118 @ 10 TICK | |----------------|-----------------------|-------------------------| | CIBCA-AA | T1025 @ 7 TICK | T1025 @ 10 TICK | |________________|_______________________|_________________________| NOTE: If all nodes in the VAXcluster system have 10 tick capability (I.E., L0118, L0100 Rev "E" and/or CIBCA-AA and NO L0100 Rev "D"), then all nodes should be set to 10 tick mode regardless of the VAXcluster system size. L0100 - Rev "E" - See page 7, step 10 for 7/10-TICK Switch setup. L0118 - Rev "B" - See page 7, step 10 for 7/10-TICK, Cluster-size Switch set-up, and Misc. Function Jumpers. CIBCA-AA - Add Jumper from E11 to E41 on VAXBI Backplane for "10-TICK INCOMPATIBLE" mode operation. Verify no jumpers D29-D59 and D30-D60 for cluster- size (NODE-COUNT) of 16 or less. Refer to CIBCA User Guide Pg. 2-10 to 2-13 for set-up. CI-LINK MODULE FCO INSTALLATION SUMMARY --------------------------------------- ********************************************************************** * INCOMPATIBILITY WARNING - L0100-E1/E2 & L0118 * * ----------------------------------------------- * * The new L0100-E1/E2 and L0118 "10-TICK-MODE" design changes are * * *** INCOMPATIBLE *** with current L0100-D1 design, and CI/HSC- * * LINK modules (L0100-E, CIBCA, L0118) set to "7-TICK-MODE". * * Mixed "7 and 10-TICK-MODE" CI-LINK operation can have severe * * impact on CI-arbitration performance and collision-rate (NO_RSP). * * For this reason, DEC does not support "10-TICK-MODE" CI-LINK * * ROLLING-UPGRADES, thus requiring a CLUSTER SHUTDOWN to "ENABLE" * * 10-TICK-MODE ** ONLY ** after all CI/HSC-nodes have been FCO'd. * * * * NOTE: High-availability customer exceptions to CLUSTER- * * SHUTDOWN "rule" should be referred to CSSE for advice on * * minimizing risks; but DEC will not assume any liabilities * * for lost data/time with such CLUSTER upgrade programs. * ********************************************************************** _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 5 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ o Forecast and obtain sufficient CI/HSCxx L0100 FCO kits for all CI7x0, CIBCI, HSCxx Cluster Nodes, ensuring availability of 1 (one) spare for every 10 (ten) FCO kits. FCO kits should NOT BE "P1 ORDERED", but should be ordered according to the Corporate Implementation Plan. CIxxx Functional Diags (EVGAA/B) from VAX Diag. Rel #31 are also recommended for checkout. o Study SWITCH/JUMPER SET-UP Procedures for L0100, L0118, and CIBCA T1025 modules for adjusting the following CI-LINK functions/modes: - "7/10-TICK" DELTA-TIME/QUIET-SLOT: + L0118 Page 7. Step 10 + L0100-E Page 7, Step 10 + T1025/CIBCA Page 7, Step 10 and CIBCA USER'S GUIDE Pg. 2-12 - CLUSTER-SIZE of 16/32 NODES: + L0118 Page 7, Step 10 + L0100-E NOT APPLICABLE + T1025/CIBCA Page 7, Step 10 and CIBCA USER'S GUIDE Pg. 2-13 - L0118 CI-LINK-MODE JUMPERS: Page 7, Step 10. o Install L0118 set to "7-TICK/COMPATIBLE-MODE" in all CI780, CI750, CIBCI, and HSC50/70 Cluster nodes. There are no prerequisite/co- requisite CIxxx or HSCxx FCOs (modules or microcode) required for L0118 upgrade in "7-TICK 16-NODE MODE", but CI780.BIN Version V8.0 and CIBCA.BIN Version V5.3 are recommended. o Schedule & perform cluster shutdown after all non-CIBCA nodes are upgraded/FCO'd, and have been tested and verified to function in "7-TICK-MODE" operation under VMS. VMS system-testing is important to early detection and repair of any DOA FCO modules, prior to disrupting VAXcluster for CI-LINK 7-to-10-TICK mode-change. ********************************************************* * IMPORTANT NOTE === IMPORTANT NOTE * * Customer should be involved or perform all CLUSTER- * * wide or node-specific VAX and HSC STARTUPS, BOOTS, * * and SHUTDOWNS. * ********************************************************* o Switch all L0100-E, L0118, and T1025/CIBCA to "10-TICK-MODE" "INCOMPATIBLE" operation. Ensure all CIs and HSCs are powered-off before changing switches/jumpers. Refer to appropriate FCO steps. Any planned CI-NODE-ADDRESSS changes should also be made at this time, with consideration of VMS SYSGEN and DECNET parameter changes required on reboot. o Reboot cluster, with customer consent, starting with HSCs. _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 6 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ CI-LINK MODULE FCO INSTALLATION PROCEDURE ----------------------------------------- 1. Shutdown the system by executing the Shutdown Command Procedure, CUSTOMER SHOULD PERFORM THIS. $ "@SYS$SYSTEM:SHUTDOWN.COM" 2. Control <CTRL> ) and HALT the system. 3. Power off the system by typing >>>POFF. 4. Open the rear doors of the CPU cabinet and the expander cabinet containing the CI (CIPA) box. 5. Set main power circuit breaker of the CPU cabinet to the OFF (0) position. 6. Set the 877 power controller main power circuit breaker of the expander cabinet containing CI (CIPA) box to the OFF (0) position. 7. Disconnect all four BNCIA cables for this VAX 8XX0 node at the SC008. Using the loopback attenuators connect: Transmit Path "A" (TA) to Receive Path "A" (RA) Transmit Path "B" (TB) to Receive Path "B" (RB) **************************************************************** * C A U T I O N * * * * The L0118 module, as all VAX modules do, * * contains electrostatic discharge sensitive * * devices (ESDS). The use of the VELOSTAT kit * * is essential to prevent damage which may not * * be noticed immediately. * * * **************************************************************** _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 7 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ 8. Set up VELOSTAT KIT a. Unfold the VELOSTAT mat to full size (24" x 24"). b. Attach the 15 foot ground cord to the VELOSTAT snap fastener on the mat. c. Attach the alligator clip end of the ground cord to a good ground on the VAX 8X00 system. d. Attach the wrist strap to either wrist and the alligator clip to a convenient portion of the mat. 9. Remove the L0100 or L0118 module from its CPU option slot and place it on the mat. Check the revision and module type: - L0100-E1/E2, or L0118, reinstall in same slot, and go to step 11 (no upgrade needed). - L0100 below Rev. E1/E2, go to step 10 to continue upgrade. Record old CI-NODE ADDRESS settings on SW1 and SW2 switches (8-switch DIP on module handle). 10. With L0118 (EQ-01454-05) on ESD Mat, configure and verify CI-LINK mode jumpers/switches for "7-TICK COMPATIBLE" MODE operation. The L0118 also contains CLUSTER-SIZE switch and 4 (four) jumpers for MISC-FUNCTIONAL-MODES which should be checked. Install the new L0118 in the CIxxx option slot. ************************************************************* * IMPORTANT - NOTE * * Copy old CI-NODE ADDRESS to new L0100/L0118. * * Ensure "7-TICK COMPATIBLE" mode is ENABLED/SET to avoid * * CI-PATH errors with L0100-D1 or other "7-TICK" CI/HSC * * nodes. The "10-TICK INCOMPATIBLE" mode cannot be used * * with L0100-D1 in cluster. Default L0100/L0118 manuf. * * switch setting should be "7-TICK COMPATIBLE" mode. * ************************************************************* SET L0100-E1 COMPATIBILITY JUMPER AS FOLLOWS: --------------------------------------------- o 7/10-TICK COMPAT. MODE SET BY 1 JUMPER @ E177 stake-pins. - "7-TICK COMPAT.-MODE": jumper E177-11 to E177-12 - "10-TICK INCOMPAT.-MODE": jumper E177-9 to E177-10 o NO CLUSTER-SIZE OR FUNCTION-MODE JUMPERS/SWITCHES. o L0100-E1 QUICK-CHECK (PART-REVISION VERIFY): - ECO wires at E177-13 and E177-9. - STAKE-PINS (for jumper) @ E177-9,10,11,12. - ETCH REV-C: P/N "50-14430C-0" marking. _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 8 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ "ECO-FIX OFF" "ECO-FIX ON" "7-TICK" "10-TICK" "COMPATIBLE" "INCOMPATIBLE" 20 +-+ 20 12 11 ...................|.|.. ........................ | . . . . . . . . | | | | . . . . . . . . . . | | E177 | | E177 | | . . . . . . . . . . | | . . . . . . . . . . | |......................| |..................|.|.| 1 9 10 1 | | +-+ SET L0100-E2 SWITCH SETTINGS AS FOLLOWS: ---------------------------------------- o 7/10-TICK COMPAT. MODE SET BY DIP-SWITCH SW3-1 LOCATED AT TOP CENTER OF L0100-E2 TO RIGHT OF E118: - "7-TICK COMPAT.,ECO OFF": SW3-1 SWITCH "OFF" - "10-TICK INCOMPAT.,ECO ON ": SW3-1 SWITCH "ON" . NOTE: SW3-2 IS NOT USED, BUT SET SAME AS SW3-1 TO AVOID CONFUSION. o NO CLUSTER-SIZE OR FUNCTION-MODE JUMPERS/SWITCHES. o L0100-E2 QUICK-CHECK (PART-REVISION VERIFY): - SW3 DUAL-SWITCH-DIP-PACK AT TOP-CENTER, RIGHT OF E118. - ETCH REV-D: P/N "50-14430-0-0 D1-P4" marking. SET L0118 SWITCH/JUMPER SETTINGS AS FOLLOWS: -------------------------------------------- **************************************************** * NOTE: REFER TO L0118 FIGURES ON FCO PAGES 11 * * AND 12 FOR SW3 AND JUMPERS W1-W4 LOCATION. * **************************************************** o 7/10-TICK COMPAT. MODE SET BY DIP-SWITCH SW3-4 LOCATED AT TOP CENTER OF L0118 TO LEFT (BELOW IF VERTICAL) OF 2 CI- NODE-ADDRESS 8-SWITCH PACKS. - "7- TICK COMPAT.,ECO OFF": SW3-4 SWITCH "OFF". - "10-TICK INCOMPAT.,ECO ON" : SW3-4 SWITCH "ON" . - SWITCHES SW3-2 AND SW3-3 MUST BE "OFF" (AFFECTS DELTA-TIME/QUIET-SLOT). o CLUSTER-SIZE FOR 16/32-NODE ADDRESSING AND ARBITRATION IS CONTROLLED BY SWITCH SW3-1. DEFAULT = 16-NODE-MODE = "OFF". - 16-NODE MODE (DEFAULT WITH NO CISCE): SW3-1 "OFF". - 32-NODE MODE (CISCE 24-NODE CLUSTER): SW3-1 "ON" . _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 9 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ o L0118 FUNCTION-MODE JUMPERS W1-W4 DEFAULT SETTINGS CHECK: View module with HANDLE-UP and FINGERS-DOWN. Refer to L0118 Figures on FCO pages 11 and 12. - L0118-B1 HAS ECO-WIRES ON E83-3 and E150-1: = W1 located left of E2: plugged on left 2 stake-pins, marked with "box". = W3 located between E54 and E75: plugged on horizontal stake-pins, marked with "box". = W2 & W4 located as 4 stake pins below E24 and E62: W2 & W4 "OUT". - L0118-B2 HAS NO ECO-WIRES TO E83-3 AND E150-1: = W1 located left of E2: W1 on left 2 stake-pins, marked with "box". = W3 located between E54 and E75: W3 on horizontal stake-pins, marked with "box". = W2 located below junction of E24 and E62: W2 on left 2 stake-pins marked with "box". = W4 located below E24: W4 plugged on left 2 stake-pins marked with "box". SET CIBCA BACKPLANE JUMPER SETTINGS AS FOLLOWS:(FOR QUICK REFERENCE) -------------------------------------------------------------------- Refer to CIBCA Users Guide Pg. 2-10 to 2-13 All jumpers are located behind T1015 Module. Jumper changes DO NOT take effect until SELF-TEST EXECUTED. o "7/10-TICK ALTER-DELTA-TIME" CONTROLLED BY JUMPER ON T1015 BACKPLANE PINS E11-E41, E09-E39, and E10-E40: - ENSURE E09-E39 and E10-E40 JUMPERS "OUT". - "7 -TICK COMPAT., ECO-OFF": Jumper OUT E11-E41. - "10-TICK INCOMPAT.,ECO-ON" : Jumper IN E11-E41. o CLUSTER-SIZE FOR 16/32-NODE ADDRESSING AND ARBITRATION IS SET BY JUMPER ON T1015 PINS D30-D60 and D29-D59: - Ensure E29-E59 out for both 16 or 32-NODE mode. - 16-NODE mode (default no CISCE): D30-D60 "OUT". - 32-NODE mode (CISCE 24-NODE ): D30-D60 "IN" . 11. Set main power circuit breaker of the CPU cabinet to the ON (1) position. 12. Set the 877 power controller main power circuit breaker of the expander cabinet containing CI (CIPA) box to the ON (1) position. 13. Close the rear doors of the CPU cabinet and the expander cabinet containing the CI (CIPA) box. _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 10 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ 14. Power on the system by typing >>>PON. 15. Run the following Level III (offline) diagnostics under the DIAG. SUPV. (DS>) E*SAA-10.8 to verify that the CIXXX is functional. DIAGNOSTIC MINIMUM VERSION TITLE ---------- --------------- ----- EVGAA 4.1 CI Functional Diag Part I EVGAB 4.1 CI Functional Diag Part II WARNING: EVGAA/B may report "false errors" when connected to "live" CLUSTER due to receipt of SCS START-DATAGRAMS from VMS. 16. Remove the loopback attenuators and reconnect the BNCIA cables to their original SC008 ports. 17. Boot system into VAXcluster, using customer's "standard operating procedures". IT IS PREFERRED THAT THE CUSTOMER PERFORM THIS STEP. EVERY UPGRADED CI/HSC NODE WITH NEW L0100-E*/L0118 SHOULD BE TESTED UNDER VMS IN "7-TICK ECO-OFF MODE" TO SYSTEM-TEST NEW FCO PARTS PRIOR TO CLUSTER-WIDE CI-LINK-MODE TRANSITION. 18. UPGRADE remaining CI750, CI780, CIBCI, HSC50, & HSC70 nodes that do not contain L0100-E1/E2 or L0118 CI-LINK module. *** REPEAT STEP 1 UNTIL ALL NODES ARE COMPLETED. *** 19. Set all CI/HSC nodes to "10-TICK, INCOMPATIBLE, ECO-ENABLED MODE" operation. *** THIS REQUIRES ENTIRE CLUSTER-SHUTDOWN TO AVOID CI-PATH FAILURES, CLUSTER-MEMBER LOSS, AND RISKS TO DATA-INTEGRITY. *** Ensure each CI is powered off when changing jumpers. Set "10-TICK, INCOMPATIBLE, ECO-ENABLED MODE" by referring to Page 7, Step 10; or use following quick reference chart: L0100-E1 L0100-E2 L0118 CIBCA E177 SW3-1 SW3-4 T1015 JUMPER SWITCH SWITCH E11-E41 ------- ------ ------ ------- 7 -TICK: 11-12 IN "OFF" "OFF" "OUT" 10-TICK: 9-10 IN "ON" "ON" "IN" Only L0100 Rev E* needs to be removed in order to set to 10-TICK. 20. Boot all systems back into VAXcluster, starting with HSCs, using customer's "standard operating procedures". IT IS PREFERRED THAT THE CUSTOMER PERFORM THIS STEP. _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 11 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ 21. Report the FCO activity on the LARS form in the "module/fail/area/ FCO" column as "FCO CIBCI-I002" as indicated. 22. Update Site Management Guide. ---------------------------------------------------------------------- LARS ---- USA GIA EUROPE Activity - Contract and Warranty W U Y Non Contract/Non Warranty F F F DEC Option CIBCI CIBCI CIBCI Type of Call M M M Action Taken D D I Fail Area-Module-FCO-Comments CIBCI-I002 CIBCI-I002 CIBCI-I002 Material Used EQ-01454-05 EQ-01454-05 EQ-01454-05 EQ-01454-04 EQ-01454-04 EQ-01454-04 FIGURE 1 - L0118 LINK MODULE SWITCHES _ _ _ _ _ _ _ | FCO CIBCI-I002 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 12 OF 12 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ FIGURE 2 - L0118 LINK MODULE SETTINGS \^ CIBCI \\CIBCI \\BRASSARD \\1988 \\JUN \\FCO_DOCS