The '''RX33 Flexible Disk Drive''' was a half height [[floppy drive]] for 5.25" 1.2 MB floppies. It is a re-badged Teac FD-55GFR drive.
 
The '''RX33 Flexible Disk Drive''' was a half height [[floppy drive]] for 5.25" 1.2 MB floppies. It is a re-badged Teac FD-55GFR drive.
  
It is supported by the [[RQDX3 MFM Disk & Floppy QBUS Controller|RQDX3]] [[QBUS]] MFM disk controller; there was no [[UNIBUS]] controller for it. Itwas also used in a large number of other DEC products; e.g. as a [[bootstrap]] device in [[Hierarchical Storage Controller]]s.
+
It is supported by the [[RQDX3 MFM Disk & Floppy QBUS Controller|RQDX3]] [[QBUS]] MFM disk controller; there was no [[UNIBUS]] controller for it. It was also used in a large number of other DEC products; e.g. as a [[bootstrap]] device in [[Hierarchical Storage Controller]]s.
  
 
==Specifications==
 
==Specifications==

Revision as of 18:52, 13 September 2023

DECmate III with RX33 in the system box underneath the monitor - the expansion box to the right contains an RX50 dual floppy drive

The RX33 Flexible Disk Drive was a half height floppy drive for 5.25" 1.2 MB floppies. It is a re-badged Teac FD-55GFR drive.

It is supported by the RQDX3 QBUS MFM disk controller; there was no UNIBUS controller for it. It was also used in a large number of other DEC products; e.g. as a bootstrap device in Hierarchical Storage Controllers.

Specifications

  • Weight - 1.10 kg (2.43 lb)
  • Height - 4.32 cm (1.70 in)
  • Width - 14.61 cm (5.75 in)
  • Depth - 20.32 cm (8.00 in)
  • Number of tracks - 80
  • Number of heads - 2
  • Track density - 96 tracks per inch
  • Step rate - 3 ms per track
  • Diskette size - 13.13 cm (5.25 in)
  • Recording surfaces per diskette - 2
  • Sectors per track
    • normal density - 10
    • high density - 15
  • Capacity
    • Bytes per drive
      • high density - 409 KB
      • normal density - 1200 KB
    • Blocks per drive
      • high density - 800
      • normal density - 2400
  • Block size - 512 bytes
  • Data transfer rate (to and from media)
    • normal density - 250 Kbits per second
    • high density - 500 Kbits per second
  • Operating power - 4.1 watts
  • Standby power - 1.5 watts

Operating Conditions

  • Temperature range - 10°C to 46°C (50°F to 115°F)
  • Temperature change rate - 11°C (20°F) per hour, maximum
  • Relative humidity - 20% to 80% noncondensing
  • Maximum wet-bulb temperature - 45°C (113°F)
  • Minimum dew-point temperature - 2°C (36°F)
  • Altitude - 2400 m (8000 ft) maximum

(Reduce maximum temperature by 1.8°C for each 1,000 meter (1.0°F for each 1,000 ft) increase in altitude.)

Nonoperating Conditions

  • Temperature - 34°C to 60°C (30°F) to 140°F)
  • Temperature change rate - 20°C (36°F) per hour, maximum
  • Relative humidity - 5% to 90%
  • Maximum wet-bulb temperature - 45°C (113°F) packaged
  • Altitude - 9100 m (30,000 ft) maximum

External links