Difference between revisions of "DR11-B parallel interface"
m (→Implementation: link ff) |
m (→Implementation: update) |
||
Line 7: | Line 7: | ||
The modules are: | The modules are: | ||
− | * M112 - NOR gates | + | * M112 - 10 x 2-input NOR gates |
* M113 - 10 x 2-input NAND gates | * M113 - 10 x 2-input NAND gates | ||
− | * M116 - NOR gates | + | * M116 - 6 x 4-input NOR gates |
* M205 - 5 x 'D' flip flops | * M205 - 5 x 'D' flip flops | ||
− | * M208 - 8-bit buffer / shift-register | + | * 2 x M208 - 8-bit buffer / shift-register |
− | * M239 - | + | * M239 - 3 x 4-bit counter/register |
* 2 x M611 - High speed power inverters | * 2 x M611 - High speed power inverters | ||
* M796 - UNIBUS Master Control | * M796 - UNIBUS Master Control | ||
* M7821 - Interrupt Control | * M7821 - Interrupt Control | ||
* M7219 - Bus Interface | * M7219 - Bus Interface | ||
+ | |||
+ | The M239's are used to hold the Status and Command Register. | ||
The M7219 is a [[DEC card form factor|quad]] card; the others are all single. (The M796 and M7821 are [[DEC card form factor|extended length]]; the others are all standard length.) | The M7219 is a [[DEC card form factor|quad]] card; the others are all single. (The M796 and M7821 are [[DEC card form factor|extended length]]; the others are all standard length.) | ||
Connection to the user device is via either a pair of M957 Split-Lug Cable boards, or via an M9760 (dual) Twisted Pair Cable Connector board. The M9680 (dual) board is a loopback test board, which can be used in place of the user connection board(s). | Connection to the user device is via either a pair of M957 Split-Lug Cable boards, or via an M9760 (dual) Twisted Pair Cable Connector board. The M9680 (dual) board is a loopback test board, which can be used in place of the user connection board(s). |
Revision as of 18:13, 4 June 2017
The DR11-B was a parallel interface for the UNIBUS which used DMA to transfer data.
Implementation
It was constructed from a number of smaller Flip Chips which were installed in custom 4-slot system unit backplane. The extant DR11-B documentation does not show either the modules used in the DR11-B, or their locations in the backplane.
The modules are:
- M112 - 10 x 2-input NOR gates
- M113 - 10 x 2-input NAND gates
- M116 - 6 x 4-input NOR gates
- M205 - 5 x 'D' flip flops
- 2 x M208 - 8-bit buffer / shift-register
- M239 - 3 x 4-bit counter/register
- 2 x M611 - High speed power inverters
- M796 - UNIBUS Master Control
- M7821 - Interrupt Control
- M7219 - Bus Interface
The M239's are used to hold the Status and Command Register.
The M7219 is a quad card; the others are all single. (The M796 and M7821 are extended length; the others are all standard length.)
Connection to the user device is via either a pair of M957 Split-Lug Cable boards, or via an M9760 (dual) Twisted Pair Cable Connector board. The M9680 (dual) board is a loopback test board, which can be used in place of the user connection board(s).