(Mostly complete) |
(→Implementation: Add DH11 board layout) |
||
Line 66: | Line 66: | ||
(DM11-BB boards are in the last two slots.) | (DM11-BB boards are in the last two slots.) | ||
+ | |||
+ | ==Early DH11 board locations== | ||
+ | |||
+ | {| class="wikitable" | ||
+ | ! !! colspan="6" | Connector | ||
+ | |- | ||
+ | ! Slot !! A !! B !! C !! D !! E !! F | ||
+ | |- | ||
+ | | 1 || colspan="2" style="text-align:center;" | UNIBUS In || colspan="2" | M7247 || M105 || M7281 | ||
+ | |- | ||
+ | | 2 || M7821 || M796 || colspan="2" | M7247 || colspan="2" style="text-align:center;" | M7246 | ||
+ | |- | ||
+ | | 3 || colspan="6" style="text-align:center;" | M7278 | ||
+ | |- | ||
+ | | 4 || colspan="6" style="text-align:center;" | M7277 | ||
+ | |- | ||
+ | | 5 || colspan="6" style="text-align:center;" | M7289 | ||
+ | |- | ||
+ | | 6 || M7821 || M405 || colspan="4" style="text-align:center;" | M7280 | ||
+ | |- | ||
+ | | 7 || M7360 || M971 || colspan="4" style="text-align:center;" | M7280 | ||
+ | |- | ||
+ | | 8 || colspan="6" style="text-align:center;" | M7288 | ||
+ | |- | ||
+ | | 9 || colspan="2" style="text-align:center;" | UNIBUS Out || colspan="2" style="text-align:center;" | M7279 || M405 || M4540 | ||
+ | |} | ||
+ | |||
+ | (DM11-BB boards are in the first two slots.) | ||
[[Category: UNIBUS Serial Interfaces]] | [[Category: UNIBUS Serial Interfaces]] |
Revision as of 21:40, 3 October 2019
The DM11-BB Modem Control Option worked with several early UNIBUS asynchronous serial line peripherals to allow the lines to be connected to modems. It could be set to interrupt the CPU when a modem control line (Ring, Carrier, etc) changed state.
The DM11-BB is logically a separate device from the serial line interfaces, albeit one housed in the same backplane. It was used with the DM11, and early models of the DH11 interfaces.
Both of these used a custom system unit backplane, containing multiple cards; a flat cable connected this to separate 5-1/4" high rack-mounted dual-height DM11 'distribution panel' backplane. Modular 'line conditioning' units from the DF11 Communications Line Adapter series were installed in the distribution panel to allow support of EIA RS-232 serial lines connected to modems.
Contents
DM11-BB Device registers
Register | Abbreviation | Address |
---|---|---|
Control and Status Register | DMCSR | 770500 |
Line Status Register | DMLSR | 770502 |
The addresses shown are for the first DM11-BB in a system; additional ones (up to 16 total) are normally set to be at 770504, 770510, etc to 770674.
770500: Control and Status Register (DMCSR)
RING | CARR | CTS | SREC | CLRSC | CLRMUX | MAINT | STEP | DONE | IE | SCEN | Unused | Line | |||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
770502: Line Status Register (DMLSR)
Unused | RING | CARR | CTS | SREC | STX | RTS | DTR | LEN | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Implementation
The DH11-BB was connected to the DM11 distribution panel via flat cables which carried the modem control signals, which ran from the M7247 card (two per card) to a single-width M971 which plugged into the backplane of the DM11 distribution panel. The DM11-BB boards (all dual-width) are:
- M7246 - Scan
- M7247 - Data Mux (two)
and 2 single-width, non-DM11-specific cards:
DM11 board locations
Board locations in the DM11 backplane (as seen from the board insertion side of the backplane, not the wire-wrap pin side, as is common in DEC documentation) are:
Connector | ||||||
---|---|---|---|---|---|---|
Slot | A | B | C | D | E | F |
1 | UNIBUS In | M7240 | ||||
2 | M105 | M7241 | ||||
3 | Power | M405 | M782 | M782 | M7242 | |
4 | M974 Cable | M7245 | ||||
1 | M7244 | |||||
2 | M7243 | |||||
3 | Power | M7247 | M7246 | |||
4 | UNIBUS Out | M7247 | M105 | M7820 |
(DM11-BB boards are in the last two slots.)
Early DH11 board locations
Connector | ||||||
---|---|---|---|---|---|---|
Slot | A | B | C | D | E | F |
1 | UNIBUS In | M7247 | M105 | M7281 | ||
2 | M7821 | M796 | M7247 | M7246 | ||
3 | M7278 | |||||
4 | M7277 | |||||
5 | M7289 | |||||
6 | M7821 | M405 | M7280 | |||
7 | M7360 | M971 | M7280 | |||
8 | M7288 | |||||
9 | UNIBUS Out | M7279 | M405 | M4540 |
(DM11-BB boards are in the first two slots.)