[[Image:DM11-BA_M8640.jpg|thumb|right|300px|DM11-BA M8640 board]]
 +
 
The '''DM11-BA Modem Control Multiplexor''' allows [[asynchronous serial line]]s connected to a  [[UNIBUS]] [[device controller]] to be connected to [[modem]]s. It could be set to [[interrupt]] the [[Central Processing Unit|CPU]] when a modem control line (Ring, Carrier, etc) changed state. It is a re-implementation of the [[DM11-BB Modem Control Option]]; instead of plugging into a controller [[backplane]] like the -BB, the -BA plugs into a standard [[UNIBUS]] [[Modified UNIBUS Device|MUD]] slot.
 
The '''DM11-BA Modem Control Multiplexor''' allows [[asynchronous serial line]]s connected to a  [[UNIBUS]] [[device controller]] to be connected to [[modem]]s. It could be set to [[interrupt]] the [[Central Processing Unit|CPU]] when a modem control line (Ring, Carrier, etc) changed state. It is a re-implementation of the [[DM11-BB Modem Control Option]]; instead of plugging into a controller [[backplane]] like the -BB, the -BA plugs into a standard [[UNIBUS]] [[Modified UNIBUS Device|MUD]] slot.
  

Revision as of 22:59, 19 September 2020

DM11-BA M8640 board

The DM11-BA Modem Control Multiplexor allows asynchronous serial lines connected to a UNIBUS device controller to be connected to modems. It could be set to interrupt the CPU when a modem control line (Ring, Carrier, etc) changed state. It is a re-implementation of the DM11-BB Modem Control Option; instead of plugging into a controller backplane like the -BB, the -BA plugs into a standard UNIBUS MUD slot.

It is program compatible with the DM11-BB (although a single DM11-BA only supports 8 lines, unlike the DM11-BB, which handled 16), and is implemented as a single hex board, the M8640.

H317-B with cover off

It connects, using two flat cables plugged into Berg headers on the board, to a passive distribution panel; either one usable with the DM11-BB (such as the H317-B), or the newer H317-M or the functionally identical H317-P (the latter has improved EMI shielding).