Difference between revisions of "Floating device address space"

From Computer History Wiki
Jump to: navigation, search
(Mostly there)
 
(probable explanation for base units)
 
(7 intermediate revisions by the same user not shown)
Line 14: Line 14:
 
| 3 || [[DQ11]] || 010
 
| 3 || [[DQ11]] || 010
 
|-
 
|-
| 4 || [[DU11]] || 010
+
| 4 || [[DU11 synchronous serial line interface|DU11]] || 010
 
|-
 
|-
 
| 5 || [[DUP11 synchronous serial line interface|DUP11]] || 010
 
| 5 || [[DUP11 synchronous serial line interface|DUP11]] || 010
Line 49: Line 49:
 
|-
 
|-
 
| 20 || [[DR11-B parallel interface|DR11-B]] || 010 || After second
 
| 20 || [[DR11-B parallel interface|DR11-B]] || 010 || After second
 +
|-
 +
| 21 || [[DMP11]] || 010
 +
|-
 +
| 22 || [[DPV11]] || 010
 +
|-
 +
| 23 || [[ISB11]] || 010
 +
|-
 +
| 24 || [[DMV11 Synchronous Controller|DMV11]] || 020
 +
|-
 +
| 25 || [[Digital Ethernet UNIBUS Network Adapter|DEUNA]] || 010
 +
|-
 +
| 26 || [[UDA50 Disk Controller|UDA50]] || 04 || Only extra
 +
|-
 +
| 27 || [[DMF32 Multi-Function Communications Interface|DMF32]] || 040
 +
|-
 +
| 28 || KMS11 || 20
 +
|-
 +
| 29 || [[VS100]] || 20
 +
|-
 +
| 30 || [[TU81 magtape drive|TU81]] || 04 || Only extra
 
|}
 
|}
 +
 +
It will be noticed that the types with an 'extra unit' annotation are all [[mass storage]] devices, generally [[disk]]s. This probably means that the 'base' unit is assigned a fixed address, so that [[bootstrap]]s do not have to contain the lengthy algorithm to deal with floating addresses in order to boot from them.
  
 
==See also==
 
==See also==
  
 
* [[Floating device vectors]]
 
* [[Floating device vectors]]
 +
 +
==Further reading==
 +
 +
* ''PDP-11 Architecture Handbook'' (not online); 'Floating CSR Address Devices', in Appendix A
 +
 +
==External links==
 +
 +
* [http://www.bitsavers.org/pdf/dec/handbooks/EB-20443-20_Peripherals_Handbook_1981.pdf peripherals handbook (1981-82)] - Appendix D, 'Floating CSR Address Devices' (pg. 494 of the PDF]
  
 
[[Category: UNIBUS]]
 
[[Category: UNIBUS]]
 
[[Category: QBUS]]
 
[[Category: QBUS]]

Latest revision as of 14:44, 8 February 2023

The floating device address space is a block of address space in the I/O page of the UNIBUS (and later the QBUS) used to hold the control registers of peripherals. Originally, each specific peripheral was assigned a fixed address for its registers; once the number of different device types became large, circa 1975, this was no longer feasible (or scalable), and the 'floating' approach was adopted instead.

In this, a block of address space (on the UNIBUS, from 0760010 to 0763776) is allocated for 'floating' devices. Within that block, devices are assigned in a fixed order, with all the devices of any type in a contiguous group. There is an empty minimum-sized group for each type of which there are no devices of that type present, and a gap between each group of devices (to mark the end of each group). (Each actual group must start on an address of the required modulus; e.g. if there is one DJ11 and one DH11, the DJ11 would be at 0760010, the 'end of DJ11s gap' would be at 0760020, the DH11 could not be at 0760030, but would have to be at 0760040.)

Floating devices, in assignment order:

Rank Device Size
(modulus)
Comment
1 DJ11 010
2 DH11 020
3 DQ11 010
4 DU11 010
5 DUP11 010
6 LK11 010
7A DMC11 010
7B DMR11 010
8 DZ11 010
9 KMC11 010
10 LPP11 010
11 VMV21 010
12 VMV31 020
13 DWR70 010
14 RL11 010 Only extra
15 LPA11 020 Only extra
16 KW11-C 010
17 Reserved 010
18 RX11 010 Only extra
19 DR11-W 010
20 DR11-B 010 After second
21 DMP11 010
22 DPV11 010
23 ISB11 010
24 DMV11 020
25 DEUNA 010
26 UDA50 04 Only extra
27 DMF32 040
28 KMS11 20
29 VS100 20
30 TU81 04 Only extra

It will be noticed that the types with an 'extra unit' annotation are all mass storage devices, generally disks. This probably means that the 'base' unit is assigned a fixed address, so that bootstraps do not have to contain the lengthy algorithm to deal with floating addresses in order to boot from them.

See also

Further reading

  • PDP-11 Architecture Handbook (not online); 'Floating CSR Address Devices', in Appendix A

External links