DN11 Automatic Calling Unit Interface: Difference between revisions

From Computer History Wiki
Jump to navigationJump to search
m →See also: +Asynchronous+Synchronous Serial Interfaces
m correct fix
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
The '''DN11 Automatic Calling Unit Interface''' was a [[UNIBUS]] [[peripheral|device]] which connected to, and allowed control of, a Bell 801 Automatic Calling Unit. The ACU could dial a telephone call on an attached telephone line; once the call had connected, a [[modem]] attached the the line, in parallel with the ACU, could establish a data link between the local modem and a remote modem. (A [[serial interface]] is required to connect the UNIBUS to the modem; that can be either [[asynchronous serial line|asynchronous]] or [[synchronous serial line|synchronous]].)
The '''DN11 Automatic Calling Unit Interface''' was a [[UNIBUS]] [[peripheral|device]] which connected to, and allowed control of, a Bell 801 Automatic Calling Unit. The ACU could dial a telephone call on an attached telephone line; once the call had connected, a [[modem]] attached to the line, in parallel with the ACU, could establish a data link between the local modem and a remote modem. (A [[serial interface]] is required to connect the UNIBUS to the modem; that can be either [[asynchronous serial line|asynchronous]] or [[synchronous serial line|synchronous]].)


==Registers==
==Registers==
Line 7: Line 7:
==Implementation==
==Implementation==


A DNll requires a custom [[system unit]] backplane and support [[printed circuit board|boards]] (the ensemble is denominated a ''''DNl1-AA'''), which can hold up to 4 independent DN11 plug-in units ('''DN11-DA'''). The DNll-AA contains:
A DNll requires a custom quad [[system unit]] backplane and support [[printed circuit board|boards]] (the ensemble is denominated a ''''DNl1-AA'''), which can hold up to 4 independent DN11 plug-in units ('''DN11-DA'''). The DNll-AA contains:


* 70-08513 Wired System Unit ([[DEC part number]])
* 70-08513 Wired System Unit ([[DEC part number]])
Line 16: Line 16:
* [[M105 Address Selector]]
* [[M105 Address Selector]]


Each DN11-DA contains:
Later versions included instead the later revision M7821 Interrupt Control. Each DN11-DA contains:


* M7226 Control Module
* M7226 Control Module ([[DEC card form factor|dual]]-width)
* BCOIR Cable Card Assembly  
* BCO1R Cable Card Assembly  


{{semi-stub}}
{{semi-stub}}

Latest revision as of 22:03, 13 October 2023

The DN11 Automatic Calling Unit Interface was a UNIBUS device which connected to, and allowed control of, a Bell 801 Automatic Calling Unit. The ACU could dial a telephone call on an attached telephone line; once the call had connected, a modem attached to the line, in parallel with the ACU, could establish a data link between the local modem and a remote modem. (A serial interface is required to connect the UNIBUS to the modem; that can be either asynchronous or synchronous.)

Registers

Each DN11 has a single control and status register. All the DN11s in a single backplane share an interrupt.

Implementation

A DNll requires a custom quad system unit backplane and support boards (the ensemble is denominated a 'DNl1-AA), which can hold up to 4 independent DN11 plug-in units (DN11-DA). The DNll-AA contains:

Later versions included instead the later revision M7821 Interrupt Control. Each DN11-DA contains:

  • M7226 Control Module (dual-width)
  • BCO1R Cable Card Assembly

See also

Further reading

  • DN11 User Manual (EK-ODN11-OP - not online)
  • DN11 Automatic Calling Unit Interface Manual (EK-ODN11-TM-002 - not online)
  • DN11 Maintenance Prints (MP-DN11-00 - not online)

External links