CIBCA-A: Difference between revisions

From Computer History Wiki
Jump to navigationJump to search
Vaxorcist (talk | contribs)
New page for DEC CIBCA-A
 
m More specific cats
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
The '''CIBCA-A''' is the [[VAX Bus Interconnect|VAXBI]] to [[CI]] Interface, 2nd Generation Adapter for the VAXBI [[VAX]] Computers.
The '''CIBCA-A''' is the 2nd Generation [[VAX Bus Interconnect|VAXBI]] to [[Computer Interconnect|CI]] interface, for [[VAX]] computers with a VAXBI.


It connects to one CI node directly, or to multiple CI nodes using the [[SC008 Star Coupler]].
It connects to one CI node directly, or to multiple CI nodes using the [[SC008 Star Coupler]].


It consists of two VAXBI cards:
It consists of two VAXBI cards:
* The CIBCA Port Controller Card [[T1015]]
* The CIBCA Port Controller Card [[T1015]]
* The CIBCA Link/Packet Buffer Card [[T1025]]
* The CIBCA Link/Packet Buffer Card [[T1025]]


Differences compared to the 1st Generation CI Adapter for the VAXBI VAX Computers:
The CIBCI was superseded by the [[CIBCA-B]] - VAXBI CI Interface, 3rd generation in 1988
* No more:
 
** CIPA (CI Port Adapter) Unit
==Differences compared to the 1st Generation CI Adapter for the VAXBI VAX Computers==
** Extra Power Supply
 
** Extra Cabinet
No more:
* but:
 
** lower power consumption
* CIPA (CI Port Adapter) Unit
** better performance
* Extra Power Supply
* Extra Cabinet
 
but:
 
* lower power consumption
* less space requirements
 
==Cabling==


Cabling:
* The T1015 and T1025 cards are connected using the 17-01504-01 and 17-01504-02 cables.  
* The T1015 and T1025 cards are connected using the 17-01504-01 and 17-01504-02 cables.  
* The 17-01473-01 bulkhead cable assembly connects from the VAXI Backplane to the CI connectors
* The 17-01473-01 bulkhead cable assembly connects from the VAXI Backplane to the CI connectors
== Documentation==


One CIBCA-A [[Field Change Order|FCO]]:
One CIBCA-A [[Field Change Order|FCO]]:
* [[FCO CIBCA-I001]]
* [[FCO CIBCA-I001]]
describes problems with and solutions for the CIBCI.  
describes problems with and solutions for the CIBCI.  
The CIBCI is superseded by the [[CIBCA-B]] - VAXBI CI Interface, 3rd generation.


==External links==
==External links==
Line 30: Line 38:
* [http://www.bitsavers.org/www.computer.museum.uq.edu.au/pdf/EK-CIBCA-UG-001%20CIBCA%20User%20Guide.pdf EK-CIBCA-UG-001 CIBCA User Guide.pdf]
* [http://www.bitsavers.org/www.computer.museum.uq.edu.au/pdf/EK-CIBCA-UG-001%20CIBCA%20User%20Guide.pdf EK-CIBCA-UG-001 CIBCA User Guide.pdf]


[[Category: VAX Peripherals]]
[[Category: VAXBI]]
[[Category: DEC Network Interfaces]]
[[Category: Computer Interconnect Interfaces]]

Latest revision as of 14:33, 15 May 2024

The CIBCA-A is the 2nd Generation VAXBI to CI interface, for VAX computers with a VAXBI.

It connects to one CI node directly, or to multiple CI nodes using the SC008 Star Coupler.

It consists of two VAXBI cards:

  • The CIBCA Port Controller Card T1015
  • The CIBCA Link/Packet Buffer Card T1025

The CIBCI was superseded by the CIBCA-B - VAXBI CI Interface, 3rd generation in 1988

Differences compared to the 1st Generation CI Adapter for the VAXBI VAX Computers

No more:

  • CIPA (CI Port Adapter) Unit
  • Extra Power Supply
  • Extra Cabinet

but:

  • lower power consumption
  • less space requirements

Cabling

  • The T1015 and T1025 cards are connected using the 17-01504-01 and 17-01504-02 cables.
  • The 17-01473-01 bulkhead cable assembly connects from the VAXI Backplane to the CI connectors

Documentation

One CIBCA-A FCO:

describes problems with and solutions for the CIBCI.

External links