Difference between revisions of "RH780 Massbus Adapter"
From Computer History Wiki
(Start with board list, docs) |
m (→External links: +VAX-11/780 Installation Manual, has section on RH780) |
||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
The '''RH780 Massbus Adapter''' was a [[MASSBUS]] [[device controller]] for the [[VAX-11/780]]'s [[Synchronous Backplane Interconnect]]. | The '''RH780 Massbus Adapter''' was a [[MASSBUS]] [[device controller]] for the [[VAX-11/780]]'s [[Synchronous Backplane Interconnect]]. | ||
− | It was implemented on four [[DEC card form factor|hex]] cards: | + | It was implemented on four [[DEC card form factor|hex]] cards, which mount in a custom 6-slot [[backplane]]: |
− | + | {| class="wikitable" | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
! Slot !! Board !! Acronym !! Function | ! Slot !! Board !! Acronym !! Function | ||
|- | |- | ||
+ | | 1 || M8275 || MSI || SBI/MBA interface | ||
+ | |- | ||
+ | | 2 || M8276 || MIR || internal registers | ||
+ | |- | ||
+ | | 3 || M8277 || MDP || MASSBUS data paths | ||
+ | |- | ||
+ | | 4 || M8278 || MCP || MASSBUS control paths | ||
+ | |} | ||
+ | |||
+ | One slot (5) is unused, and one slot (6) is used (on the back of the backplane) to hold a hex M9041 paddle card, which carries the MASSBUS out on three BC06R [[flat cable]]s to what appears to be a standard MASSBUS connector, in an 'expansion I/O connector' on the side of the cabinet. | ||
+ | |||
+ | {{semi-stub}} | ||
+ | |||
+ | ==See also== | ||
− | + | * [[DW780 Unibus Adapter]] | |
==External links== | ==External links== | ||
− | * [http://www.bitsavers.org/pdf/dec/vax/780/EK-RH780-TD-001_RH780_Technical_Description_197903.pdf RH780 Massbus Adapter Technical Description] (EK-RH780-TD-001) | + | * [http://www.bitsavers.org/pdf/dec/vax/780/EK-RH780-TD-001_RH780_Technical_Description_197903.pdf RH780 Massbus Adapter Technical Description] (EK-RH780-TD-001) <!-- https://bitsavers.org/pdf/dec/vax/780/fiche/EK-RH780-TD_TechDescr_Mar79.pdf --> |
* [http://www.bitsavers.org/pdf/dec/vax/780/MP00499_RH780_Nov77.pdf RH780 Field Maintenance Print Set] (MP-00499) | * [http://www.bitsavers.org/pdf/dec/vax/780/MP00499_RH780_Nov77.pdf RH780 Field Maintenance Print Set] (MP-00499) | ||
+ | * [http://bitsavers.org/pdf/dec/vax/780/EK-SI780-IN-002_VAX-11_780_Installation_Manual_198201.pdf VAX-11/780 Installation Manual] (EK-SI780-IN-002) - contains a section on the RH780, Chapter 7 (on pp. 63-66 of the PDF) | ||
− | |||
[[Category: MASSBUS Controllers]] | [[Category: MASSBUS Controllers]] | ||
+ | [[Category: SBI]] |
Latest revision as of 20:06, 15 May 2024
The RH780 Massbus Adapter was a MASSBUS device controller for the VAX-11/780's Synchronous Backplane Interconnect.
It was implemented on four hex cards, which mount in a custom 6-slot backplane:
Slot | Board | Acronym | Function |
---|---|---|---|
1 | M8275 | MSI | SBI/MBA interface |
2 | M8276 | MIR | internal registers |
3 | M8277 | MDP | MASSBUS data paths |
4 | M8278 | MCP | MASSBUS control paths |
One slot (5) is unused, and one slot (6) is used (on the back of the backplane) to hold a hex M9041 paddle card, which carries the MASSBUS out on three BC06R flat cables to what appears to be a standard MASSBUS connector, in an 'expansion I/O connector' on the side of the cabinet.
See also
External links
- RH780 Massbus Adapter Technical Description (EK-RH780-TD-001)
- RH780 Field Maintenance Print Set (MP-00499)
- VAX-11/780 Installation Manual (EK-SI780-IN-002) - contains a section on the RH780, Chapter 7 (on pp. 63-66 of the PDF)