KW11-P Programmable Real-Time Clock: Difference between revisions

From Computer History Wiki
Jump to navigationJump to search
Fairly complete
 
m →External links: Bitsavers has reorganized a bit
 
Line 41: Line 41:
==External links==
==External links==


* [http://www.bitsavers.org/pdf/dec/unibus/DEC-11-HPWB-D_KW11P_Oct72.pdf KW11-P programmable real-time clock manual] (DEC-11-HPWB-D)
* [http://www.bitsavers.org/pdf/dec/unibus/KW11-P/DEC-11-HPWB-D_KW11P_Oct72.pdf KW11-P programmable real-time clock manual] (DEC-11-HPWB-D)
* [http://www.bitsavers.org/pdf/dec/unibus/KW11-P_Schem_Aug73.pdf KW11-P programmable real-time clock engineering drawings]
* [http://www.bitsavers.org/pdf/dec/unibus/KW11-P/KW11-P_Schem_Aug73.pdf KW11-P programmable real-time clock engineering drawings]


[[Category: UNIBUS Peripherals]]
[[Category: UNIBUS Peripherals]]

Latest revision as of 14:37, 7 October 2026

The KW11-P Programmable Real-Time Clock is a UNIBUS device option which can either provide interval counting, or produce either single or repeated interrupts at a programmed rate (at a multiple of the base rate). Four different base clock rates are available:

  • 100 KHz
  • 10 KHz
  • line rate from the AC power provided to the power supply
  • external

The programming interface is fairly simple; there are three registers:

  • control/status
  • count set
  • counter

The counter register can be set to count up or down, governed by the selected rate; an interrupt can be triggered when it reaches 0 (on overflow or underflow). It can then optionally be automatically reloaded from the count set register.

Implementation

Physically, the KW11-P is an quad-height board (M7228), which plugs into a SPC slot in a backplane.

Control and Status Register (CSR)

ERR Unused DONE INTENB FIX UP/DN MODE RATE RUN
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
  • ERR - Overflow/underflow before previous interrupt completed
  • DONE - Set on overflow/underflow (causes an interrupt when that happens, if the INTENB bit is set)
  • INTENB - Interrupt enable
  • FIX - Diagnostic count
  • MODE - Count up/down
  • MODE - Single/repeat interrupt
  • RATE
    • 00 - 100 KHz
    • 01 - 10 KHz
    • 10 - line
    • 11 - external

All bits are read/write, except FIX (write-only), and DONE and ERR (read-only).

External links