Difference between revisions of "RP06 disk drive"
From Computer History Wiki
m (Jnc moved page RP06 to RP06 disk drive: canonical naming scheme) |
(Update to modest contents, same as otehr RP0x pages) |
||
Line 1: | Line 1: | ||
− | + | {{Infobox Disk drive | |
+ | | name = RP06 | ||
+ | | manufacturer = Memorex (basic drive), [[Digital Equipment Corporation]] (electronics) | ||
+ | | capacity = 176 Mbytes | ||
+ | | controller = [[RH11 MASSBUS controller|RH11]] ([[UNIBUS]]) | ||
+ | | average access time = 38.3 msec | ||
+ | | transfer rate = 806 KB/s (peak) | ||
+ | | rpm = 3600 | ||
+ | | revolution time = 8.3 msec | ||
+ | | one track seek = 10 msec | ||
+ | | average seek = 30 msec | ||
+ | <!-- | maximum seek = msec --> | ||
+ | | surfaces = 20 (19 data, 1 servo) | ||
+ | | tracks = 815 | ||
+ | | sectors = 22 | ||
+ | | words per sector = 256 | ||
+ | | tracks per inch = 384 | ||
+ | | density = 4040 bpi (maximum) | ||
+ | | recording method = [[Modified Frequence Modulation]] (MFM) | ||
+ | | physical size = 33" W x 47" H x 32" L | ||
+ | | weight = 600 pounds | ||
+ | | power consumption = 660 VA per phase (running); 3300 VA per phase (starting, 10 seconds max) | ||
+ | }} | ||
+ | |||
+ | The '''RP06''' was the successor to the [[RP04 disk drive|RP04]] multi-[[platter]] large [[disk]] drives. The actual drive was a Memorex 677-01, [[OEM]]'d by [[DEC]], who added interface electonics. | ||
+ | |||
+ | As a [[MASSBUS]] device, it did not have a specific [[device controller]], but used the appropriate MASSBUS controller. A maximum of 8 drives were supported per controller; drives could be dual-ported, to allow access from two different controllers. | ||
+ | |||
+ | The block headers are protected by a [[CRC]], and the data by an [[ECC]]. | ||
+ | |||
+ | {{stub}} | ||
[[Category:DEC Disk Drives]] | [[Category:DEC Disk Drives]] |
Revision as of 14:09, 3 October 2017
RP06 | |
Manufacturer: | Memorex (basic drive), Digital Equipment Corporation (electronics) |
---|---|
Drive Controller(s): | RH11 (UNIBUS) |
Capacity: | 176 Mbytes |
Transfer Rate: | 806 KB/s (peak) |
Average Access Time: | 38.3 msec |
Revolutions per Minute: | 3600 |
1/2 Revolution Time: | 8.3 msec |
One Track Seek Time: | 10 msec |
Average Seek Time: | 30 msec |
Total Surfaces: | 20 (19 data, 1 servo) |
Tracks per Surface: | 815 |
Sectors per Track: | 22 |
Words per Sector: | 256 |
Tracks per Inch: | 384 |
Density: | 4040 bpi (maximum) |
Recording Method: | Modified Frequence Modulation (MFM) |
Physical Size: | 33" W x 47" H x 32" L |
Weight: | 600 pounds |
Power Consumption: | 660 VA per phase (running); 3300 VA per phase (starting, 10 seconds max) |
The RP06 was the successor to the RP04 multi-platter large disk drives. The actual drive was a Memorex 677-01, OEM'd by DEC, who added interface electonics.
As a MASSBUS device, it did not have a specific device controller, but used the appropriate MASSBUS controller. A maximum of 8 drives were supported per controller; drives could be dual-ported, to allow access from two different controllers.
The block headers are protected by a CRC, and the data by an ECC.