DIA20 IBus Adapter: Difference between revisions

From Computer History Wiki
Jump to navigationJump to search
An OK start
 
+img of IBus conn
Line 2: Line 2:


==Implementation==
==Implementation==
[[Image:KIKLIOBusTerm.jpg|300px|right|thumb|IBus [[terminator]]]]


The DIA20 is connected to the EBox of the KL10 via the EBus; when no other controller on the EBus responds to a command, the DIA20 will respond, and send the command out the IBus. Similarly, [[interrupt]] requests from IBus devices are sent through to the EBox.
The DIA20 is connected to the EBox of the KL10 via the EBus; when no other controller on the EBus responds to a command, the DIA20 will respond, and send the command out the IBus. Similarly, [[interrupt]] requests from IBus devices are sent through to the EBox.


It consists of a number of [[DEC card form factor|hex]] boards (two M8550s and an M8551) plugged into an I/O [[backplane]] (one shared with the [[DMA20 Memory Bus Controller‏‎]]) of the KL10; these are connected to new-style I/O bus connectors mounted lower down in that rack.
It consists of a number of [[DEC card form factor|hex]] boards (two M8550s and an M8551) plugged into an I/O [[backplane]] (one shared with the [[DMA20 Memory Bus Adapter‏‎]]) of the KL10; these are connected to new-style I/O bus connectors mounted lower down in that rack.


==External links==
==External links==

Revision as of 20:31, 12 October 2021

The DIA20 IBus Adapter (sometimes called the DIA20 In/Out Bus Controller) is an optional controller on KL10 CPUs which provides an old-style PDP-10 I/O bus (termed an 'IBus'), to allow existing PDP-10 peripherals to be used on one. Two separate IBuses are provided per CPU. (In a multi-processor system, each CPU has a separate DIA20, if configured to have one.)

Implementation

IBus terminator

The DIA20 is connected to the EBox of the KL10 via the EBus; when no other controller on the EBus responds to a command, the DIA20 will respond, and send the command out the IBus. Similarly, interrupt requests from IBus devices are sent through to the EBox.

It consists of a number of hex boards (two M8550s and an M8551) plugged into an I/O backplane (one shared with the DMA20 Memory Bus Adapter‏‎) of the KL10; these are connected to new-style I/O bus connectors mounted lower down in that rack.

External links