Difference between revisions of "TUK50 Host Adapter Module"
From Computer History Wiki
m (→External links: +TK50 Tape Drive Subsystem Technical Manual) |
(Copyedit excess verbiage from cut-and-paste) |
||
Line 1: | Line 1: | ||
[[Image:tuk50.jpg|thumb|200px|right|thumb|TUK50-AA board]] | [[Image:tuk50.jpg|thumb|200px|right|thumb|TUK50-AA board]] | ||
+ | |||
+ | The '''TUK50 Host Adapter Module''' is a [[UNIBUS]] [[device controller]] for the [[TK50 Tape Drive|TK50]] [[magnetic tape drive]]. It uses [[Mass Storage Control Protocol|TMSCP]]. | ||
− | + | It is a [[DEC card form factor|quad]] [[printed circuit board|board]], the '''M7547''', and plugs into an [[Small Peripheral Controller|SPC]] slot. | |
==Installation== | ==Installation== | ||
− | + | [[Image:TUK50_M7547_Jumpers.png|thumb|400px|left|thumb|TUK50 M7547 Jumpers]] | |
− | + | The TK50 responds to two [[address]]es on the UNIBUS; the initialize poll (IP) [[register]] and the status address (SA) register. The installer may change these addresses by changing the address [[jumper]]s on the board. The first TK50's UNIBUS base address is normally 0774500; additional unit are assigned [[floating device address space|floating addresses]]. | |
− | |||
− | The | ||
− | |||
− | |||
− | |||
− | |||
The controller module has the following jumpers and switches: | The controller module has the following jumpers and switches: | ||
− | * Jumper W51, W61, W401 - | + | * Jumper W51, W61, W401 - Manufacturing use only |
− | * Jumpers W1 through W12 | + | * Jumpers W1 through W12 - Address |
− | * Jumper W201 -- | + | * Jumper W201 - Non-existent memory timeout extension - With the jumper removed, the non-existent memory timeout is extended from 28 nanoseconds to 37 microseconds; the manufacturing configuration is 'installed' |
− | * Hardware revision | + | * Hardware revision - An 8-wide [[DIP switch]] used to set the hardware revision level of the module; 'open' on a switch reads as '0' |
− | * Unit number | + | * Unit number - An 8-wide DIP switch used to set the TMSCP unit number; the sense is as the above |
− | + | <br clear=all> | |
==External links== | ==External links== |
Revision as of 14:49, 13 November 2022
The TUK50 Host Adapter Module is a UNIBUS device controller for the TK50 magnetic tape drive. It uses TMSCP.
It is a quad board, the M7547, and plugs into an SPC slot.
Installation
The TK50 responds to two addresses on the UNIBUS; the initialize poll (IP) register and the status address (SA) register. The installer may change these addresses by changing the address jumpers on the board. The first TK50's UNIBUS base address is normally 0774500; additional unit are assigned floating addresses.
The controller module has the following jumpers and switches:
- Jumper W51, W61, W401 - Manufacturing use only
- Jumpers W1 through W12 - Address
- Jumper W201 - Non-existent memory timeout extension - With the jumper removed, the non-existent memory timeout is extended from 28 nanoseconds to 37 microseconds; the manufacturing configuration is 'installed'
- Hardware revision - An 8-wide DIP switch used to set the hardware revision level of the module; 'open' on a switch reads as '0'
- Unit number - An 8-wide DIP switch used to set the TMSCP unit number; the sense is as the above
External links
- TK50 Unibus Subsystem Owner's Manual (EK-TUK50-OM-001) - ZIP archive of TIF page images
- TK50 Tape Drive Subsystem Technical Manual (EK-0TK50-TM-002) - the TUK50 is covered in Chapter 6