RP06 disk drive: Difference between revisions
From Computer History Wiki
Jump to navigationJump to search
m Jnc moved page RP06 to RP06 disk drive: canonical naming scheme |
Update to modest contents, same as otehr RP0x pages |
||
| Line 1: | Line 1: | ||
{{Infobox Disk drive | |||
| name = RP06 | |||
| manufacturer = Memorex (basic drive), [[Digital Equipment Corporation]] (electronics) | |||
| capacity = 176 Mbytes | |||
| controller = [[RH11 MASSBUS controller|RH11]] ([[UNIBUS]]) | |||
| average access time = 38.3 msec | |||
| transfer rate = 806 KB/s (peak) | |||
| rpm = 3600 | |||
| revolution time = 8.3 msec | |||
| one track seek = 10 msec | |||
| average seek = 30 msec | |||
<!-- | maximum seek = msec --> | |||
| surfaces = 20 (19 data, 1 servo) | |||
| tracks = 815 | |||
| sectors = 22 | |||
| words per sector = 256 | |||
| tracks per inch = 384 | |||
| density = 4040 bpi (maximum) | |||
| recording method = [[Modified Frequence Modulation]] (MFM) | |||
| physical size = 33" W x 47" H x 32" L | |||
| weight = 600 pounds | |||
| power consumption = 660 VA per phase (running); 3300 VA per phase (starting, 10 seconds max) | |||
}} | |||
The '''RP06''' was the successor to the [[RP04 disk drive|RP04]] multi-[[platter]] large [[disk]] drives. The actual drive was a Memorex 677-01, [[OEM]]'d by [[DEC]], who added interface electonics. | |||
As a [[MASSBUS]] device, it did not have a specific [[device controller]], but used the appropriate MASSBUS controller. A maximum of 8 drives were supported per controller; drives could be dual-ported, to allow access from two different controllers. | |||
The block headers are protected by a [[CRC]], and the data by an [[ECC]]. | |||
{{stub}} | |||
[[Category:DEC Disk Drives]] | [[Category:DEC Disk Drives]] | ||
Revision as of 13:09, 3 October 2017
| RP06 | |
| Manufacturer: | Memorex (basic drive), Digital Equipment Corporation (electronics) |
|---|---|
| Drive Controller(s): | RH11 (UNIBUS) |
| Capacity: | 176 Mbytes |
| Transfer Rate: | 806 KB/s (peak) |
| Average Access Time: | 38.3 msec |
| Revolutions per Minute: | 3600 |
| 1/2 Revolution Time: | 8.3 msec |
| One Track Seek Time: | 10 msec |
| Average Seek Time: | 30 msec |
| Total Surfaces: | 20 (19 data, 1 servo) |
| Tracks per Surface: | 815 |
| Sectors per Track: | 22 |
| Words per Sector: | 256 |
| Tracks per Inch: | 384 |
| Density: | 4040 bpi (maximum) |
| Recording Method: | Modified Frequence Modulation (MFM) |
| Physical Size: | 33" W x 47" H x 32" L |
| Weight: | 600 pounds |
| Power Consumption: | 660 VA per phase (running); 3300 VA per phase (starting, 10 seconds max) |
The RP06 was the successor to the RP04 multi-platter large disk drives. The actual drive was a Memorex 677-01, OEM'd by DEC, who added interface electonics.
As a MASSBUS device, it did not have a specific device controller, but used the appropriate MASSBUS controller. A maximum of 8 drives were supported per controller; drives could be dual-ported, to allow access from two different controllers.
The block headers are protected by a CRC, and the data by an ECC.