[[File:BA23 Enclosure Pedestal Version (MicroVAX).png|400px|thumb|left|BA23 Enclosure Pedestal Version (MicroVAX)]]
+
[[File:BA23 Enclosure Pedestal Version (MicroVAX).png|350px|thumb|right|BA23 Enclosure Pedestal Version (MicroVAX)]]
  
The BA23 [[Qbus]] enclosure is available in pedestal, tabletop, and rack mount installations.
+
The '''BA23 Enclosure''' is a [[QBUS]] [[mounting box]] from [[Digital Equipment Corporation|DEC]] which is available in pedestal, table-top, and rack mount versions. There is also a 'bigger brother', the [[BA123]] enclosure.
 
 
There is a 'bigger brother' the '''[[BA123]]''' enclosure.
 
  
 
The BA23 enclosure is famous for the risk to skin one's knuckles - it is packed inside very tightly.
 
The BA23 enclosure is famous for the risk to skin one's knuckles - it is packed inside very tightly.
 
<br clear=all>
 
  
 
==BA23 Usage==
 
==BA23 Usage==
  
The BA23 enclosure was used for the following [[DEC]] [[PDP-11]] and [[MicroVAX]] computers:
+
The BA23 enclosure was used for the following DEC [[PDP-11]] and [[MicroVAX]] computers:
  
* [[PDP-11/53]], also named 'MicroPDP-11'
+
* [[PDP-11/53]], also named 'MicroPDP-11'
 
* [[PDP-11/73]]
 
* [[PDP-11/73]]
 
* [[PDP-11/83]]
 
* [[PDP-11/83]]
Line 26: Line 22:
 
Some versions of the computers listed above were also available in the BA123 enclosure, or in the [[H9642]] Medium System Cabinet.
 
Some versions of the computers listed above were also available in the BA123 enclosure, or in the [[H9642]] Medium System Cabinet.
  
The H9642 Medium System Cabinet containes two BA23 enclosures, one 'Standard' BA23-A, and one 'Expander' BA23-C.
+
The H9642 Medium System Cabinet contains two BA23 enclosures, one 'Standard' BA23-A, and one 'Expander' BA23-C.
  
In the cabinet both BA23 enclosures are connected with a '''[[BCV2A]]''' 'Qbus expansion cable and terminator BA23A to BA23C' to provide a large Qbus configuration.
+
In the cabinet both BA23 enclosures are connected with a [[BCV2A]] 'Qbus expansion cable and terminator BA23A to BA23C' to provide a large Qbus configuration.
  
 
==BA23 Mass Storage Device Areas==
 
==BA23 Mass Storage Device Areas==
[[File:BA23 Mass Storage Locations.png|400px|thumb|left|BA23 Mass Storage Locations A & B]]
+
 
 +
[[File:BA23 Mass Storage Locations.png|300px|thumb|left|BA23 Mass Storage Locations A & B]]
  
 
The BA23 can hold full-height and half-height 13.3 cm (5.25 in) mass storage devices, depending on the system.
 
The BA23 can hold full-height and half-height 13.3 cm (5.25 in) mass storage devices, depending on the system.
Line 45: Line 42:
  
 
==BA23 Control Panel==
 
==BA23 Control Panel==
 +
 
The BA23 has either a 4- or 6-button control panel as follows:
 
The BA23 has either a 4- or 6-button control panel as follows:
  
[[File:BA23 4-Button Control Panel and PC Board (Example).png|400px|thumb|left|BA23 4-Button Control Panel and PC Board (Example)]]
+
[[File:BA23 4-Button Control Panel and PC Board (Example).png|300px|thumb|right|BA23 4-Button Control Panel and PC Board (Example)]]
  
 
Systems with a 4-button control panel support only full-height mass storage devices.
 
Systems with a 4-button control panel support only full-height mass storage devices.
Line 53: Line 51:
 
<br clear=all>
 
<br clear=all>
  
[[File:BA23 6-Button Control Panel and PC Board (Example).png|400px|thumb|left|BA23 6-Button Control Panel and PC Board (Example)]]
+
[[File:BA23 6-Button Control Panel and PC Board (Example).png|300px|thumb|right|BA23 6-Button Control Panel and PC Board (Example)]]
  
 
Systems with a 6-button control panel support either full-height or half-height devices.
 
Systems with a 6-button control panel support either full-height or half-height devices.
Line 61: Line 59:
 
==BA23 Signal Distribution Panel==
 
==BA23 Signal Distribution Panel==
  
[[File:BA23 Signal Distribution Panel.png|400px|thumb|left|BA23 Signal Distribution Panel]]
+
[[File:BA23 Signal Distribution Panel.png|300px|thumb|left|BA23 Signal Distribution Panel]]
  
 
The signal distribution panel carries signals from an [[RQDX1]], [[RQDX2]], or [[RQDX3]] controller module in the [[QBUS#Variable_address_size|Q22-bus]] backplane to the mass storage devices.
 
The signal distribution panel carries signals from an [[RQDX1]], [[RQDX2]], or [[RQDX3]] controller module in the [[QBUS#Variable_address_size|Q22-bus]] backplane to the mass storage devices.
Line 69: Line 67:
 
==BA23 H9278 Backplane==
 
==BA23 H9278 Backplane==
  
[[File:BA23 Backplane Grant Continuity.png|400px|thumb|left|BA23 H9278 Qbus Backplane Grant Continuity]]
+
[[File:BA23 Backplane Grant Continuity.png|350px|thumb|right|BA23 H9278 Qbus Backplane Grant Continuity]]
  
The BA23 enclosure contains the [[QBUS_backplanes#Backplane types|H9278]] Qbus backplane.
+
The BA23 enclosure contains the [[QBUS_backplanes#Backplane types|H9278]] Qbus [[backplane]].
  
The picture shows the H9278 Qbus Backplane Grant Continuity.
+
The picture shows the H9278 Qbus Backplane [[bus grant]] continuity.
  
 
Slots 1-3 are Q/CD; slots 4-8 are Q/Q
 
Slots 1-3 are Q/CD; slots 4-8 are Q/Q
Line 81: Line 79:
 
==BA23 Internal Cabling==
 
==BA23 Internal Cabling==
  
[[File:BA23 Internal Cabling (Example).png|400px|thumb|left|BA23 Internal Cabling (Example)]]
+
[[File:BA23 Internal Cabling (Example).png|300px|thumb|left|BA23 Internal Cabling (Example)]]
 
 
  
 
<br clear=all>
 
<br clear=all>
Line 88: Line 85:
 
==BA23 H7864 Power Supply==
 
==BA23 H7864 Power Supply==
  
[[File:BA23 Power Supply.png|400px|thumb|left|BA23 H7864 Power Supply]]
+
[[File:BA23 Power Supply.png|300px|thumb|right|BA23 H7864 Power Supply]]
  
There are three variations of the BA23 power supply, depending on the enclosure model number:
+
There are three variations of the BA23 [[power supply]], depending on the enclosure model number:
 
H7864, H7864A, or H7864B.
 
H7864, H7864A, or H7864B.
  
The power supply regulators maintain proper output voltages against temporary fluctuations in the ac input to the power supply.
+
The power supply regulators maintain proper output [[voltage]]s against temporary fluctuations in the ac input to the power supply.
  
The powersupply is a 230 W unit. It supplies +5 Vdc at 4.5 amps (A) to 36.0 A, and +12 Vdc at 0.0 A to 7.0 A to the following system components:
+
The power supply is a 230 W unit. It supplies +5 Vdc at 4.5 amps (A) to 36.0 A, and +12 Vdc at 0.0 A to 7.0 A to the following system components:
  
 
* Backplane
 
* Backplane
Line 112: Line 109:
  
 
==BA23 I/O Panel==
 
==BA23 I/O Panel==
[[File:BA23 I-O Panel.png|400px|thumb|left|BA23 I/O Panel Adapter plate with typical type A and B inserts]]
+
 
 +
[[File:BA23 I-O Panel.png|300px|thumb|right|BA23 I/O Panel Adapter plate with typical type A and B inserts]]
  
 
You use the I/O panel to connect external devices to the system.  
 
You use the I/O panel to connect external devices to the system.  
Line 144: Line 142:
 
You can install three more type A inserts by removing the bracket between the third and fourth cutouts and installing an adapter plate.  
 
You can install three more type A inserts by removing the bracket between the third and fourth cutouts and installing an adapter plate.  
  
== References ==
+
==External links==
  
* [http://bitsavers.trailing-edge.com/scandocs.trailing-edge.com/micropdp11-volume_2_enclosures-EK-186AA-MG-001.pdf EK-186AA-MG-001 BA23 Enclosure Maintenance]
+
* [http://bitsavers.trailing-edge.com/scandocs.trailing-edge.com/micropdp11-volume_2_enclosures-EK-186AA-MG-001.pdf BA23 Enclosure Maintenance] (EK-186AA-MG-001)
  
 
[[Category: DEC Hardware]]
 
[[Category: DEC Hardware]]
 
{{Nav VAX}}
 

Revision as of 03:13, 16 June 2022

BA23 Enclosure Pedestal Version (MicroVAX)

The BA23 Enclosure is a QBUS mounting box from DEC which is available in pedestal, table-top, and rack mount versions. There is also a 'bigger brother', the BA123 enclosure.

The BA23 enclosure is famous for the risk to skin one's knuckles - it is packed inside very tightly.

BA23 Usage

The BA23 enclosure was used for the following DEC PDP-11 and MicroVAX computers:

Some versions of the computers listed above were also available in the BA123 enclosure, or in the H9642 Medium System Cabinet.

The H9642 Medium System Cabinet contains two BA23 enclosures, one 'Standard' BA23-A, and one 'Expander' BA23-C.

In the cabinet both BA23 enclosures are connected with a BCV2A 'Qbus expansion cable and terminator BA23A to BA23C' to provide a large Qbus configuration.

BA23 Mass Storage Device Areas

BA23 Mass Storage Locations A & B

The BA23 can hold full-height and half-height 13.3 cm (5.25 in) mass storage devices, depending on the system.

You can install one RD5x-series fixed-disk drive and one removable-media drive — an RX50 diskette drive or a TK50 tape drive. You cannot install two full-height, fixed-disk drives due to power limitations.

You can connect external drives to the system’s I/O distribution panel.

The number of drives you can use depends on the space available in the I/O panel and backplane, and the amount of power available to run the drive controllers.


BA23 Control Panel

The BA23 has either a 4- or 6-button control panel as follows:

BA23 4-Button Control Panel and PC Board (Example)

Systems with a 4-button control panel support only full-height mass storage devices.


BA23 6-Button Control Panel and PC Board (Example)

Systems with a 6-button control panel support either full-height or half-height devices.


BA23 Signal Distribution Panel

BA23 Signal Distribution Panel

The signal distribution panel carries signals from an RQDX1, RQDX2, or RQDX3 controller module in the Q22-bus backplane to the mass storage devices.


BA23 H9278 Backplane

BA23 H9278 Qbus Backplane Grant Continuity

The BA23 enclosure contains the H9278 Qbus backplane.

The picture shows the H9278 Qbus Backplane bus grant continuity.

Slots 1-3 are Q/CD; slots 4-8 are Q/Q


BA23 Internal Cabling

BA23 Internal Cabling (Example)


BA23 H7864 Power Supply

BA23 H7864 Power Supply

There are three variations of the BA23 power supply, depending on the enclosure model number: H7864, H7864A, or H7864B.

The power supply regulators maintain proper output voltages against temporary fluctuations in the ac input to the power supply.

The power supply is a 230 W unit. It supplies +5 Vdc at 4.5 amps (A) to 36.0 A, and +12 Vdc at 0.0 A to 7.0 A to the following system components:

  • Backplane
  • Fixed-disk drive
  • Diskette drive or tape drive


The power supply also sends three system control signals to the backplane, asserting two of these signals (BDCOK H and BPOK H) when the system power is stable. The third signal (BEVENT L) is an external line clock interrupt request to the CPU. The LTC switch on the control panel PC board enables the BEVENT signal.

The power supply also has two +10 Vdc at 0.45 A fan outputs for the front and rear dc fans. You can increase the fan voltages to +12 Vdc by changing a power supply jumper. The KA630 CPU module’s thermal and acoustical specifications for example, are based on the +10 volt setting. The required fan power does not affect the 230 W output.

BA23 I/O Panel

BA23 I/O Panel Adapter plate with typical type A and B inserts

You use the I/O panel to connect external devices to the system.

Each device connects to a module in the system through a filtered connector.

You mount the connector on an insert, then install the insert in a cutout on the I/O panel.

Filtered connectors and inserts are part of the option’s cabinet kit.

Usually, the CPU insert is installed in the top (or left) cutout.

The I/O panel has six cutouts in two sizes, types A and B.


BA23 I/O Panel Cutout and Insert Sizes
Type Quantity C/I Inches Millimeters
A 2 Cutout 0.6 x 3.2 15 x 81
A 2 Insert 1.0 x 4.0 25 x 102
B 4 Cutout 2.25 x 3.2 57 x 81
B 4 Insert 2.5 x 3.3 64 x 84

You can install three more type A inserts by removing the bracket between the third and fourth cutouts and installing an adapter plate.