TUK50 Host Adapter Module

From Computer History Wiki
Revision as of 14:49, 13 November 2022 by Jnc (talk | contribs) (Copyedit excess verbiage from cut-and-paste)
Jump to: navigation, search
TUK50-AA board

The TUK50 Host Adapter Module is a UNIBUS device controller for the TK50 magnetic tape drive. It uses TMSCP.

It is a quad board, the M7547, and plugs into an SPC slot.

Installation

TUK50 M7547 Jumpers

The TK50 responds to two addresses on the UNIBUS; the initialize poll (IP) register and the status address (SA) register. The installer may change these addresses by changing the address jumpers on the board. The first TK50's UNIBUS base address is normally 0774500; additional unit are assigned floating addresses.

The controller module has the following jumpers and switches:

  • Jumper W51, W61, W401 - Manufacturing use only
  • Jumpers W1 through W12 - Address
  • Jumper W201 - Non-existent memory timeout extension - With the jumper removed, the non-existent memory timeout is extended from 28 nanoseconds to 37 microseconds; the manufacturing configuration is 'installed'
  • Hardware revision - An 8-wide DIP switch used to set the hardware revision level of the module; 'open' on a switch reads as '0'
  • Unit number - An 8-wide DIP switch used to set the TMSCP unit number; the sense is as the above


External links