DL10 PDP-11 Data Link
The DL10 PDP-11 Data Link connects PDP-10 mainframes to PDP-11s used as communication front ends; up to 4 PDP-11's per DL10. It allows the PDP-10 to 'see' into the PDP-11's main memory, and vice versa (although the ability of the PDP-11 to do so is limited by the DL10's settings).
On the PDP-10 side, it connected to the PDP-10 Memory Bus, and also up to two PDP-10 I/O Busses (allowing it to be controlled by both processors in a multi-CPU system). So, it could be connected to KA10s and KI10s, but only to KL10s with the optional old-style I/O busses (via a DIA20 IBus Adapter).
On the PDP-11 side, PDP-11's connected to the DL10 have a special console which has a cable which goes to the DL10, which allows the PDP-10 to start and stop the PDP-11; the PDP-11's UNIBUS runs into the DL10 and is plugged into the DL10's backplane.
There is little remaining DL10 documentation, alas; see below for links to what exists online.
Contents
Data formats
Note that the format is selected by the second octet in the word; the values used in that octet to select the byte size in the 'pointer' mode are disjoint from the values used in that octet for the other modes.
Immediate mode
Unused | 0 or 7 | Unused | Data | ||||||||||||||||||||||||||||||||
00 | 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 |
Indirect mode
A | P | 1 | Unused | Address | |||||||||||||||||||||||||||||||
00 | 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 |
A | Access |
---|---|
0 | Read or write |
1 | Read only |
P | 16-bit word position within 36-bit word |
---|---|
0 | Bits 0-15 |
1 | Bits 16-31 |
2 | Bits 20-35 |
3 | Bits 2-17 |
Pointer modes
P | S | Word count | Address | ||||||||||||||||||||||||||||||||
00 | 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 |
Bytes are left-justified inside a 36-bit word.
S | Byte size |
---|---|
2 | 16 |
3 | 12 |
4 | 8 |
5 | 7 |
6 | 6 |
PDP-11 control and status registers
DATO 100000 (Conditions out)
Set 11 interrupt | Clear 11 interrupt | Set 10 interrupt | Clear 10 interrupt | Set nonex memory | Clear nonex memory | Set parity error | Clear parity error | Set word count overflow | Clear word count overflow | Error interrupt enable | 11 interrupt enable | Interrupt assignment | |||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
DATI 100000 (Status)
11 interrupt | 10 interrupt | Nonex memory | Set parity error | Word count overflow | This port enabled | Error interrupt enable | 11 interrupt enable | Interrupt assignment | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
PDP-10 standard instructions
CONO DLB,
Base address | Mask for size of pointer block | PDP-11 | |||||||||||||||
18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 |
CONO DLC,
Clear DL10 | Lock DL10 | Action of 1s | 11 interrupt | Port enable | 10 interrupt | 11 interrupt | Port enable | 10 interrupt | 11 interrupt | Port enable | 10 interrupt | 11 interrupt | Port enable | 10 interrupt | Priority interrupt assignment | ||
18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 |
CONI DLB,
Diag | Diag msyn | Diag C0 | Diag C1 | Diag R2 | Diag R1 | Diag INH CYC | 11-3 8K option | 11-2 8K option | 11-1 8K option | 11-0 8K option | IOC lock on | ~IOC lock delay on | ~IOC lock 1 out | ~IOC lock 0 out | 18-bit address | Standard interrupt | Got DL10 locked | 11 interrupt | Port enable | 10 interrupt | 11 interrupt | Port enable | 10 interrupt | 11 interrupt | Port enable | 10 interrupt | 11 interrupt | Port enable | 10 interrupt | Priority interrupt assignment | |||||
00 | 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 |
External links
- BOOT11 - PDP-11 Bootstrap From PDP-10 - contains general description of the DL10 in section 4.0
- DECsystem-10 System Reference Manual - documents the PDP-10's DL10 control instructions in Appendix C (on pp. 365-368 of the PDF)
- DN87 Field Maintenance Print Set - contains complete engineering drawings for the DL10 (on pp. 100-212 of the PDF)