Difference between revisions of "DEC indicator panel"

From Computer History Wiki
Jump to: navigation, search
m (+cat)
(Add image of one in an H960 cabinet)
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
The earlier computers from [[Digital Equipment Corporation]], such as the [[KA10]], in common with the other computers of the day, included many so-called '''indicator panels''', containing arrays of lights which provided information about the internal state of the machine. Not only the [[CPU]] had such lights; other devices such as [[disk controller]]s also had their own indicator panels.
+
[[Image:RF11indicator.jpg|thumb|right|150px|[[RF11 disk controller|RF11]] indicator panel mounted, as usual, at the top of an [[H960 rack|H960 cabinet]]]]
 +
 
 +
'''Indicator panels''', containing arrays of lights which provided information about the internal state of the machine, were provided by [[Digital Equipment Corporation|DEC]] for their earlier computers (such as the [[KA10]]), in common with the other computers of the day. Not only the [[Central Processing Unit|CPU]] had such lights; other devices such as [[disk]] [[device controller|controllers]] also had their own indicator panels.
 
   
 
   
 
This tradition lasted through the early models of the [[PDP-8 family|PDP-8]] and [[PDP-11]], although the PDP-11 CPU light displays were modest compared to earlier CPUs. The earliest PDP-11 disk controllers were very much a match for the earlier machines, though, and included indicator panels which displayed a great deal of information.  
 
This tradition lasted through the early models of the [[PDP-8 family|PDP-8]] and [[PDP-11]], although the PDP-11 CPU light displays were modest compared to earlier CPUs. The earliest PDP-11 disk controllers were very much a match for the earlier machines, though, and included indicator panels which displayed a great deal of information.  
  
Alas, the cost of such displays was high, and they were dropped from later controllers. This was a significant loss; in addition to helping with debugging (both hardware and software issues), they gave an extensive insight into how the machine was operating.  
+
Alas, the cost of such displays was high, and they were dropped from later controllers. (The only PDP-11 controllers with indicator panels were the [[RF11 disk controller|RF11]], the [[RP11 disk controller|RP11]], and the [[DX11-B System 360/370 Channel to PDP-11 Unibus Interface|DX11]]; the [[RK11-C disk controller|RK11-C]] was wired for one, but DEC never even produced the 'inlay' - a clear plastic panel, with black paint with holes for the lights on the back, and white caption lettering on the front - for it. This was likely connected to the fact that these controllers were the only ones built out of a large number of small [[FLIP CHIP]]s in a large custom [[backplane]].) This was a significant loss; in addition to helping with debugging (both hardware and software issues), they gave an extensive insight into how the machine was operating.  
  
 
==Details==
 
==Details==
  
PDP-10 devices which used a 19 inch rack, along with the few types of PDP-10 [[main memory]] which came in such racks, used a standard indicator panel. The panel provided 4 rows of 36 lights each (although not all were used; unused lights were simply not wired up). Only the 'inlay' (a clear plastic panel, with black paint with holes for the lights, and white caption lettering on the front) was customized to the particular device.  
+
[[Image:DX11IndicatorPanel.jpg|thumb|left|300px|Indicator panel from a [[DX11-B System 360/370 Channel to PDP-11 Unibus Interface|DX11]]]]
 +
 
 +
PDP-10 devices which used a 19 inch rack, along with the few types of PDP-10 [[main memory]] which came in such racks, used a standard indicator panel. The panel provided 4 rows of 36 lights each (although not all were used; unused lights were simply not wired up). Only the inlay was customized to the particular device.  
 
   
 
   
The PDP-8 and PDP-11, although not 36-bit machines, also used the same indicator panel, but in general did not include any 36-bit fields. (The exception is the [[RP11 disk controller|RP11]], which was able to read packs written on a PDP-10, and thus included a 36-bit shift register, which was displayed on the RP11-C panel.)
+
The PDP-8 and PDP-11, although not 36-bit machines, also used the same indicator panel, but in general did not include any 36-bit fields. (The exception is the RP11, which was able to read packs written on a PDP-10, and thus included a 36-bit shift register, which was displayed on the RP11-C panel.)
  
 
The 18-bit [[PDP-15]] also used this indicator panel.
 
The 18-bit [[PDP-15]] also used this indicator panel.
Line 15: Line 19:
 
The two groups differed in the white bezel; in the PDP-10's, the bezel is metal, and goes over the inlay; in the PDP-11's, the bezel is plastic, and the inlay is laid into the bezel.
 
The two groups differed in the white bezel; in the PDP-10's, the bezel is metal, and goes over the inlay; in the PDP-11's, the bezel is plastic, and the inlay is laid into the bezel.
  
Limited engineering drawings (they do not include the full mechanical drawings) for this indicator panel are included in the [[RF11]] Engineering Drawings set; the indicator panel is shown on pp. 186-190. Of particular interest are the parts lists, which include all the inlays extant as of the date of the drawings (10/1972).  
+
Limited engineering drawings (they do not include the full mechanical drawings) for this indicator panel are included in the RF11 Engineering Drawings set; the indicator panel is shown on pp. 186-190. Of particular interest are the parts lists, which include all the inlays extant as of the date of the drawings (10/1972).  
 +
 
 +
==See also==
 +
 
 +
* [[Front panel]]
  
 
==External links==
 
==External links==
  
 +
* [http://www.bitsavers.org/pdf/dec/unibus/RF11_EngrDrws_Oct70.pdf RF11/RS11 DECdisk system engineering drawings] - contains the engineering drawings for the indicator panel (on pp. 186-190 of the PDF)
 
* [http://ana-3.lcs.mit.edu/~jnc/tech/DECIndicatorPanels.html Digital Equipment Corporation Indicator Panels] - Includes images of many of the panels
 
* [http://ana-3.lcs.mit.edu/~jnc/tech/DECIndicatorPanels.html Digital Equipment Corporation Indicator Panels] - Includes images of many of the panels
 +
* [http://www.bitsavers.org/pdf/dec/unibus/5408458_ind_panel/back.jpg Image of back] - includes mounting hardware
 +
* [http://www.bitsavers.org/pdf/dec/unibus/5408458_ind_panel/front.jpg Image of front] - includes cables and paddle cards
  
 
[[Category: Digital Equipment Corporation]]
 
[[Category: Digital Equipment Corporation]]
[[Category: DEC Hardware]]
 

Latest revision as of 20:33, 5 January 2024

RF11 indicator panel mounted, as usual, at the top of an H960 cabinet

Indicator panels, containing arrays of lights which provided information about the internal state of the machine, were provided by DEC for their earlier computers (such as the KA10), in common with the other computers of the day. Not only the CPU had such lights; other devices such as disk controllers also had their own indicator panels.

This tradition lasted through the early models of the PDP-8 and PDP-11, although the PDP-11 CPU light displays were modest compared to earlier CPUs. The earliest PDP-11 disk controllers were very much a match for the earlier machines, though, and included indicator panels which displayed a great deal of information.

Alas, the cost of such displays was high, and they were dropped from later controllers. (The only PDP-11 controllers with indicator panels were the RF11, the RP11, and the DX11; the RK11-C was wired for one, but DEC never even produced the 'inlay' - a clear plastic panel, with black paint with holes for the lights on the back, and white caption lettering on the front - for it. This was likely connected to the fact that these controllers were the only ones built out of a large number of small FLIP CHIPs in a large custom backplane.) This was a significant loss; in addition to helping with debugging (both hardware and software issues), they gave an extensive insight into how the machine was operating.

Details

Indicator panel from a DX11

PDP-10 devices which used a 19 inch rack, along with the few types of PDP-10 main memory which came in such racks, used a standard indicator panel. The panel provided 4 rows of 36 lights each (although not all were used; unused lights were simply not wired up). Only the inlay was customized to the particular device.

The PDP-8 and PDP-11, although not 36-bit machines, also used the same indicator panel, but in general did not include any 36-bit fields. (The exception is the RP11, which was able to read packs written on a PDP-10, and thus included a 36-bit shift register, which was displayed on the RP11-C panel.)

The 18-bit PDP-15 also used this indicator panel.

The two groups differed in the white bezel; in the PDP-10's, the bezel is metal, and goes over the inlay; in the PDP-11's, the bezel is plastic, and the inlay is laid into the bezel.

Limited engineering drawings (they do not include the full mechanical drawings) for this indicator panel are included in the RF11 Engineering Drawings set; the indicator panel is shown on pp. 186-190. Of particular interest are the parts lists, which include all the inlays extant as of the date of the drawings (10/1972).

See also

External links