The '''KY11-LB Programmer's Console''' was an option for the [[PDP-11/04]] and the [[PDP-11/34]] which provided the functionality of a conventional 'lights and switches' front panel.
 
The '''KY11-LB Programmer's Console''' was an option for the [[PDP-11/04]] and the [[PDP-11/34]] which provided the functionality of a conventional 'lights and switches' front panel.
  
It consisted of a front panel, an M7859 [[DEC card form factor|quad]] card which plugged into any available [[UNIBUS]] [[Small Peripheral Controller|SPC]] slot in the [[backplane]] holding the [[CPU]], and a 20-conductor flat cable which connected the two.
+
It consisted of a front panel, and an M7859 [[DEC card form factor|quad]] card which plugged into any available [[UNIBUS]] [[Small Peripheral Controller|SPC]] slot in the [[backplane]] holding the [[CPU]], and a 20-conductor flat cable which connected the two.
  
The front panel had an octal keypad, a 6-digit LED display which showed address and data information, and the following function keys:
+
The front panel had an octal keypad, a 6-digit [[LED]] display which showed address and data information, several individual indicator LEDs, and the following function keys:
  
 
* CLR - Clear
 
* CLR - Clear
Line 18: Line 18:
 
* BOOT
 
* BOOT
  
In addition, several other functions were actuated by use of the 'Control' and various numeric keys.
+
In addition, several other functions were actuated by use of the 'Control' key along with various numeric keys.
  
 
The front panel also had six indicators:
 
The front panel also had six indicators:
Line 25: Line 25:
 
* SR DISP - Switch Register Display
 
* SR DISP - Switch Register Display
 
* BUS ERR - Bus Error
 
* BUS ERR - Bus Error
* MAINT - Maintainence
+
* MAINT - Maintenance
 
* BATT - Battery
 
* BATT - Battery
 
* DC ON
 
* DC ON
Line 31: Line 31:
 
==Cable connection==
 
==Cable connection==
  
The KY11-LB maintainence manual contains a major error, in describing the configuration of the flat cable that connectors the front panel and the UNIBUS interface module. This is covered in Chapter 9, "Installation", which includes two figures, Figures 9-4 and 9-5.
+
The KY11-LB maintenance manual contains a major error, in describing the configuration of the flat cable that connects the front panel and the UNIBUS interface module. This is covered in Chapter 9, "Installation", which includes two figures, Figures 9-4 and 9-5.
  
Those figures show the 20-conductor flat cable with the red edge stripe toward the outer edge of the front panel [[PCB]] (correct), and also toward the outer edge of the M7859 ('''WRONG'''). On the M7859, the red stripe edge needs to be ''away'' from the outer edge of the board.
+
Those figures show the 20-conductor flat cable with the red edge stripe oriented toward the outer edge of the front panel [[PCB]] (correct), and also toward the outer edge of the M7859 ('''WRONG'''). On the M7859, the red stripe edge needs to be '''''away''''' from the outer edge of the board.
  
 
If it is plugged in as shown in these figures, the machine will not operate: the four 'RUN/SR DISP/BUS ERR/MAINT' lights will be on, but nothing else, and it will not respond to any keys. Fortunately, plugging the cable in reversed does not damage anything; simply reverse the cable.
 
If it is plugged in as shown in these figures, the machine will not operate: the four 'RUN/SR DISP/BUS ERR/MAINT' lights will be on, but nothing else, and it will not respond to any keys. Fortunately, plugging the cable in reversed does not damage anything; simply reverse the cable.

Revision as of 13:23, 29 March 2016

The KY11-LB Programmer's Console was an option for the PDP-11/04 and the PDP-11/34 which provided the functionality of a conventional 'lights and switches' front panel.

It consisted of a front panel, and an M7859 quad card which plugged into any available UNIBUS SPC slot in the backplane holding the CPU, and a 20-conductor flat cable which connected the two.

The front panel had an octal keypad, a 6-digit LED display which showed address and data information, several individual indicator LEDs, and the following function keys:

  • CLR - Clear
  • LAD - Load Address
  • DIS AD - Display Address
  • LSR - Load Switch Register
  • EXAM -Examine
  • DEP - Deposit
  • CNTRL - Control - Used to enable the following keys:
  • INIT - Initialize
  • HALT/SS - Halt/Single-Step (the latter without 'Control')
  • CONT - Continue
  • START
  • BOOT

In addition, several other functions were actuated by use of the 'Control' key along with various numeric keys.

The front panel also had six indicators:

  • RUN
  • SR DISP - Switch Register Display
  • BUS ERR - Bus Error
  • MAINT - Maintenance
  • BATT - Battery
  • DC ON

Cable connection

The KY11-LB maintenance manual contains a major error, in describing the configuration of the flat cable that connects the front panel and the UNIBUS interface module. This is covered in Chapter 9, "Installation", which includes two figures, Figures 9-4 and 9-5.

Those figures show the 20-conductor flat cable with the red edge stripe oriented toward the outer edge of the front panel PCB (correct), and also toward the outer edge of the M7859 (WRONG). On the M7859, the red stripe edge needs to be away from the outer edge of the board.

If it is plugged in as shown in these figures, the machine will not operate: the four 'RUN/SR DISP/BUS ERR/MAINT' lights will be on, but nothing else, and it will not respond to any keys. Fortunately, plugging the cable in reversed does not damage anything; simply reverse the cable.

References

  • EK-KY1LB-MM-001, KY11-LB programmer's console/interface module operation and maintenance manual