VAX-11/785 Revision Control
From Computer History Wiki
_ K-RM-11785 Rev A, VAX 11/785 Revision Matrix Document, Sep 1990 *********************************************************************** * THE FOLLOWING DOCUMENT IS A PRELIMINARY UPDATE TO THE 11785 REVISION* * MATRIX. OFFICIAL ECOS HAVE NOT BEEN PROCESSED TO UPDATE THIS RM DOC.* *********************************************************************** 5/18/88 Rose Murphy CSSE 11/785 REVISION MATRIX DOCUMENT ------------------------------- TABLE OF CONTENTS ----------------- Page 1.0 INTRODUCTION..................................... 2 1.1 REVISION CONTROL............................ 2 1.1.1 PART REVISION........................ 2 1.1.2 UNIT/COMBINATION OF UNIT REVISION.... 3 2.0 SYSTEM ID REGISTER............................... 3 2.1 HOW TO READ SID............................. 3 2.2 HOW TO SET SID.............................. 3 2.3 HOW TO SET SID FOR 11/785 UPGRADES.......... 5 3.0 11/785 UPGRADES.................................. 5 4.0 HOW TO READ REV MATRICES......................... 6 5.0 UNIT REVISION MATRICES........................... 6 5.1 11/785...................................... 7 5.2 KA785....................................... 13 ** 5.3 MS780-E..................................... 17 ** 5.4 MS780-H..................................... 19 5.5 FP785 ...................................... 21 6.0 *APPENDIX......................................... 24-34 6.1 KC785 Chart................................. 6.2 MS780-C Chart............................... 6.3 DW780 REV MATRIX............................ 6.4 RH780 Chart................................. 6.5 DR780 Chart................................ 6.6 MA780 Chart................................. ** 6.7 CI780 Chart................................. - 2 - 1.0 INTRODUCTION ------------ The purpose of this document is to define the compatible revision levels of the 11/785 system and options. Revision levels are tracked according to DEC Standard 068. A team composed of Engineering, Manufacturing and Customer Services will review all changes and determine when the revisions in this document will be changed. This document is under ECO control and will be updated by Engineering via the normal ECO process. This RM document can be obtained in the following manner: (1) Order from Engineering Design Services by P/N RM-11785. (2) VAX Library Microfiche (3) ENET - VOLKS::CLUSTER$REV:785REV.DOC (Latest version always available) (4) Speed Bulletin #407 This document will be updated when an ECO is generated to a part that causes the revision of the unit and/or combination of units to change. Note that some 11/780 options that are used on the 11/785 do not follow the revision tracking scheme as outlined in this document. These are older products that will be converted to DEC Standard 012 and 068 over time. 1.1 REVISION CONTROL ---------------- Definitions: Part - FRU (module, backplane, power supply, etc.) Unit - Option (FP785, KA785) Combination of Units - System (11/785) All revisions noted in this document are MINIMUM REVISIONS. Higher revisions are compatible unless otherwise noted. 1.1.1 Part Revisions -------------- Part revisions are tracked according to DEC Standard 012 conventions. Each part has an alphanumeric revision, up to a maximum of 4 digits. When a part revision changes, the alpha or numeric characters may change. If the alpha character changes, the new and old revisions are not interchangeable. If the numeric only changes, the parts are interchangeable within the common alpha revisions, i.e. D1, D2 and D3 are all interchangeable. Note that only the alpha character will be tracked for part revisions in this document. Minor revision (numeric) changes will not be noted. - 3 - 1.1.2 Unit Revision ------------- Unit and combination of unit revisions will be tracked via an alpha character only; minor revision (numeric) changes will not be noted. 2.0 SYSTEM ID REGISTER ------------------ The System ID Register on the 11/785 is implemented in the same way as the 11/780 SID register. It is accessible, as in the 11/780, by reading ID register 03 or internal processor register number 3E from the console. (See Section 1.2.1) The register format for the 11/785 is as follows: 31 24 23 22 21 18 17 15 14 12 11 00 +---------------------------------------------------------------+ | SYSTEM | XX | XX | N | PLANT | SERIAL NUMBER | | TYPE | |----------------| | | | | | SYSTEM REVISION| | | +---------------------------------------------------------------+ 2.1 How to read SID Register ------------------------ Example: (underlined portion is what you type) >>> E/ID 3 ---- - ID 00000003 018032B2 * -or- >>> E/I 3E --- -- I 0000003E 018032B2 * * (Sys type = 780; CPU type = 785; Sys rev = 0; plant = Franklin; last 3 digits represent serial number) 2.2 How to set SID Register ----------------------- KA785 Backplane Jumpers (located on the upper right hand corner of backplane) A UU A UU A UU A UU _______________ _______________ _______________ _______________ |:::::::::::::| |:::::::::::::| |:::::::::::::| |:::::::::::::| --------------- --------------- --------------- --------------- B J10 VV B J11 VV B J12 VV B J13 VV - 4 - Remove Jumper to Assert bit. Bit Jumper Description 0 J13 VV Serial Number 1 J13 TT 100 - 4095 2 J13 RR (An "A" is placed prior to the serial number 3 J13 NN on the cabinet for the second series of numbers. 4 J13 LL A "B" will be places prior to the number should 5 J13 JJ that be necessary.) 6 J13 FF 7 J13 DD 8 J13 BB 9 J13 Z 10 J13 X 11 J13 V 12 J13 T Mfg. Plant 13 J13 R 0 = NI (Salem FA&T) 3 = FX (Franklin) 14 J13 N 1 = GAlway 4 = FX (2nd series) 2 = SV (2nd series) 5 = 780-5, 785 upgrades 6 = BTO (Burlington,Vt) 15 J13 L System Revision Letter 16 J13 J 0 = either 0 or blank 3 = D 6 = H 17 J13 F 1 = B 4 = E 7 = J 2 = C 5 = F 18 J13 D System Revision Number 19 J13 B 0 = Rev 0 . 20 J12 VV 1 = Rev 1 . 21 J12 TT 2 = Rev 2 15 = Rev 15 22 J12 RR CPU Type 23 J12 NN 0X = 780 10 = 785 24 J12 LL System Type 25 J12 JJ 1 = 780 26 J12 FF 2 = 750 27 J12 DD 3 = 730 28 J12 BB 29 J12 Z 30 J12 X 31 J12 V - 5 - The above allows for the following distinctions: 1. distinctions between 780s and 785s. (bit 23 set=785, clear=780) 2. distinctions between manufactured 785s and 785 upgrades. (Manufacturing Plant Field, 5 = 785 upgrade, 3 or 4 = 785 original build) 3. unique System ID Register for all 780s, 785s, and 785 upgrades manufactured by the corporation. 2.3 How to set SID Register for 11/785 Upgrades ------------------------------------------- Installation of a 785 Upgrade will require that Field Service set the serial number jumpers on the new backplane to equal the serial number of the 780 being replaced. This is done by removing from the KA785 J13-V through J13-VV any jumpers necessary to duplicate the jumper configuration of the KA780 J13-V through J13-VV. This will give the KA785 the same serial number as the removed KA780 serial number. 3.0 11/785 UPGRADES (11/780 TO 11/785) ---------------------------------- All 11780 systems that are to be upgraded to an 11785 or 11/780-5 must be at a minimum hardware rev 04. In addition, the following minimum revisions are required: RH780 Rev 04, AA1 or B1 MS780-C Rev 1B DW780 Rev 1B (Rev C1 for UDA50s) CI780- Rev C1 All existing revisions of all other VAX options are compatible. NOTE: RH780 REV 04, AA1, B1: The RH780 Rev 4 or AA1 is the minimum required for all 11785 systems. RH780 AA1 is the same as Rev 04. AA1 implements Part Revision. Rev B1 replaces the M8277 module with the M8274 module which is needed for high speed RP07s. Note that the 11/780, 11780-5 and 11/785 systems may contain a mixture of RH780 Rev 04 (AA1) and RH780 Rev B1 with no compatibility problems. - 6 - 4.0 HOW TO READ REVISION MATRICES ----------------------------- This document is broken into two major sections: (1) Description of changes (History Page). This describes what parts/units were changed and why. It will contain the following at a minimum: ECO #, Problem corrected, symptom, new part revision, quick check, FCO # and any other comments that the team decides is necessary. (2) Matrices showing revision compatibilities. These matrices list the MINIMUM compatible revisions for each unit (option) or combination of units (system). Higher revisions are also compatible unless otherwise noted. To determine compatible revisions, begin with the highest level matrix to determine minimum compatible revisions for the combination of units (system). Then, refer to the revision matrices for each unit (option) to determine the revisions for the parts contained in that unit. As stated previously, this document does NOT track the numeric portion of the part revision. For instance, a part could have three usable and shippable revisions - A1, A2 and A3 - but only "A" will show on the chart--all three revisions are interchangeable. 5.0 UNIT REVISION MATRICES This section contains the rev matrix charts and history pages for the 11/785 kernal options - 11/785, KA785, KC785, MS780-C/E/H. The matrices or revision charts for other VAX options that can be used on the 11/785 are attached at the end of this document. - 7 - 5.1 11/785 ------------------------------------------------------------------------------ | OPTION NAME | | | 11785-AA-AD | | |----------------------------------------------------------------------------| | 11785-TW001 11785 Revision "00" | | ----------- | | This is the initial introduction of the Revision matrix on the 11785. | | This R.M. represents the minimum system rev. level "00" at FCS, June 1984.| | Minimum EVNDX to support Rev. 00 is 16 which went out with each system/ | | upgrade. | | | | To set the SID register for system revision 00 bits 15:21 should be clear;| | therefore, corresponding jumpers should be installed. (Install J12 TT, and| | VV, install J13B thru J13L). SSU01A.WCS is on the console floppy P/N | | AS-T793B-ME. | | | | 11785-TW002 11/785 Revision "01" | | ----------- | | Update the RM to reflect ECOs to the KA785 and FP785. This brings the | | 11785 system to revision "01". To set SID to revision "01" jumpers J12 TT| | and VV, J13 B and J13 F through J13 L must be installed. Jumper J13 D | | must be removed. Manufacturing implementation date is October 29, 1984. | | | | 11785-TW003 | | ----------- | | Created new 11785 systems using the new MS780-H memory option. | | This document will track 11785-AA-AD systems (MS780-E memory config) | | and 11785-AE-AJ systems (MS780-H memory config) separately. | | | | 11785-TW004 | | ----------- | | Documentation ECO--not applicable to this document. | | | | 11785-TW005 11/785 Revision "02" | | ----------- | | 1.Change the microcode part number (SSU01A.WCS)in the parts no.column | | to indicate a more generic form (SSUXXX.WCS) in order to track rev's | | in the matrix. | | 2.Revision 01B (SSU01B.WCS), p/n AST793D.ME fixes one of the decimal | | string instructions. This microcode change was made available in diag- | | nostic release 18. | | | | | | | | | | | | | | | | | | | |----------------------------------------------------------------------------| | | | | | | | | 11785 | | | D | I | G | I | T | A | L | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |____________________________________________________________________________| - 8 - ________________________________________________________________________________ | OPTION NAME | | | 11785-AA-AD (Cont.) | | |____________________________|_________________________________________________| | | | 11785-TW005 (Cont.) | | | | 3.Revision 01C (SSU01C.WCS), p/n AST793F.ME fixes a microcode bug for the | | REMQUE Instruction. This change brings the system rev to "02" and the | | KA785 to Rev "C". | | | | To set the SID to revision "02" remove the jumper at J13B and install it | | at J13D on the backplane. This microcode change was made available in | | diagnostic release 21. | | | | 4.Add new 11/785 variations - AF, AH and AK (8 mb of MS780-H memory.) | | | | 5.Update the RM documents to reflect the proper revision and to combine | | multiple variations. | | | | | | 11785-MK006 | | ----------- | | | | 1.Update RM to reflect ECOs to the MS780-E, MS780-H, KA785, FP785 and | | CPU microcode (SSU01D.WCS). Changes to the 11/785 system rev are | | as follows: | | | | w/KA785 w/MS780 w/FP785 w/KA785 & w/KA785,MS780 | | Current ECOs ECOs ECOs MS780 & FP785 | | Rev ONLY ONLY ONLY ECOs ECOs | | ------- ------- ------- ------- --------- ------------- | | 2.0 3.0 2.B 2.0 3.B 3.B | | | | Corresponding SID register changes are: | | | | From 2.0 to 2.B = Remove jumper J13-L | | From 2.0 to 3.0 = Remove jumper J13-D | | From 2.B to 3.B = Remove jumper J13-D | | From 3.0 to 3.B = Remove jumper J13-L | | | | | | | | | | | | | | | | | | | | | | | | | |------------------------------------------------------------------------------| | | | | | | | | 11/785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_______________| - 9 - ______________________________________________________________________________ | OPTION NAME | R | | | | | | 11785-AA-AD & 780UP-* | E | 00 | 01 | 01 | 02 | |________________________________________|_V_|_______|_______|_______|_______| | PART NO. | DESCRIPTION | | 11785 | CPU | |___________|________________________________________________________________| | | | | | | | |KA785 | CPU KERNAL | *00 | B | B | C | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |KC785-FA,FC| CONSOLE | 00 | A | A | A | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |MS780-C | MEMORY | 1B | 1B | 1B | 1B | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |MS780-E | MEMORY | *00 | 00 | 00 | 00 | |-----------|--------------------------------|-------|-------|-------|-------| |FP785 | FLOATING POINT ACCELERATOR | *00 |***D | D | D | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |DW780 | UNIBUS ADAPTOR | 01,C1+| 01,C1 | 01,C1 | 01,C1 | |___________|________________________________|_______|_______|_______|_______| | | | | |3.5/ |3.5/ | |VMS | VIRTUAL MEMORY OPERATING SYSTEM| 3.5 | 3.5 | 4.0 | 4.0 | |-----------|--------------------------------|-------|-------|-------|-------| |EVNDX | VAX DIAGNOSTIC INDEX | | | 16/ | 16/ | | | (EXCLUSIVE OF CPU MICROCODE) | 16 | 16 | 18** | 18** | |___________|________________________________|_______|_______|_______|_______| |SSUXXX.WCS | SUSPERSTAR MICROCODE | 01A | 01A | 01B | 01C | |AS-T793*-ME| VAX 11/785 CONSOLE | B | B | C | F | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869D | POWER CONTROLLER (U.S.) | H | H | H | H | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869E | POWER CONTROLLER (EUROPE) | F | F | F | F | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | E | | | | |*OPTION REVISION 00 IS | E H | C |11/785-|11/785-|11/785-TW005 | | EQUIVALENT TO "A" | V I | O |TW001 |TW002 | | |**VMS 4.X REQUIRES DIAG. REL.18| I S | | | | | |*** SYS REV. IS NOT AFFECTED BY| I O | N | | | | | REV OF FP785. ALL FP785s | O R | O | | | | | SHOULD BE BROUGHT TO REV | N Y |___|_______|_______|_______________| | "D" (see Sec 5.4 of 11785 | | D |10/ |11/ | 2/ | | R.M.Document.) | | A | 01/ | 13/ | 26/ | |+ See Note on Page 10. | | T | 84 | 84 | 86 | |_______________________________|________|_E_|_______|_______|_______________| | | | | | | | |TITLE | | | | | | | | | | 11/785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| -10- ______________________________________________________________________________ | OPTION NAME | R | | | | | | 11785-AA-AD & 780UP-* | E | 2B | 03 | 3B | | |________________________________________|_V_|_______|_______|_______|_______| | PART NO. | DESCRIPTION | | 11785 | CPU | |___________|________________________________________________________________| | | | | | | | |KA785 | CPU KERNAL | C | D | D | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |KC785-FA,FC| CONSOLE | A | A | A | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |MS780-C | MEMORY | 1B | 1B | 1B | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |MS780-E | MEMORY | B | *00 | B | | |-----------|--------------------------------|-------|-------|-------|-------| |FP785 | FLOATING POINT ACCELERATOR | D | E | E | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |DW780 | UNIBUS ADAPTOR | 01,C1+| 01,C1 | 01,C1 | | |___________|________________________________|_______|_______|_______|_______| | | |3.5/ |3.5/ |3.5/ | | |VMS | VIRTUAL MEMORY OPERATING SYSTEM| 4.0 | 4.0 | 4.0 | | |___________|________________________________|_______|_______|_______|_______| |EVNDX | VAX DIAGNOSTIC INDEX |16/ |16/ |16/ | | | | (EXCLUSIVE OF CPU MICROCODE) | 18** | 18** | 18** | | |___________|________________________________|_______|_______|_______|_______| |SSUXXX.WCS | SUSPERSTAR MICROCODE | 01C | 01D | 01D | | |AS-T793*-ME| VAX 11/785 CONSOLE | F | J | J | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869D | POWER CONTROLLER (U.S.) | H | H | H | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869E | POWER CONTROLLER (EUROPE) | F | F | F | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | E | | | | | |*OPTION REVISION 00 IS | E H | C |11/785-|11/785-|11/785-| | | EQUIVALENT TO "A" | V I | O |MK006 |MK006 |MK006 | | |**VMS 4.X REQUIRES DIAG. REL.18| I S | | | | | | | | I O | N | | | | | |+ C1 Rev should be installed | O R | O | | | | | | (M8271 Rev "F") if Unibus | N Y |___|_______|_______|_______|_______| | timeouts occur on devices | | D | | | | | | that use buffered data paths.| | A | | | | | | (FCO DW780-S-00C1) | | T | 86 | 86 | 86 | | |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | 11/785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| - 11 - ______________________________________________________________________________ | OPTION NAME | R | | | | | | 11785-AE-AK | E | 01 | 02 | 2B | 03 | |________________________________________|_V_|_______|_______|_______|_______| | PART NO. | DESCRIPTION | |11785 | CPU | |___________|________________________________________________________________| | | | | | | | | | | | | | | |KA785 | CPU KERNAL | B | C | C | D | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |KC785-FA,FC| CONSOLE | A | A | A | A | | FD | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | |MS780-H | MEMORY | 00 | 00 | B | 00 | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |FP785 | FLOATING POINT ACCELERATOR | D | D | D | E | |___________|________________________________|_______|_______|_______|_______| | | | +| | | | |DW780 | UNIBUS ADAPTOR | 01,C1 | 01,C1 | 01,C1 | 01,C1 | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |VMS | VIRTUAL MEMORY OPERATING SYSTEM| 4.0 | 4.0 | 4.0 | 4.0 | |___________|________________________________|_______|_______|_______|_______| |EVNDX | VAX DIAGNOSTIC INDEX | | | | | | | (EXCLUSIVE OF CPU MICROCODE) | 18 | 18 | 18 | 18 | |___________|________________________________|_______|_______|_______|_______| |SSUXXX.WCS | SUSPERSTAR MICROCODE | 01B | 01C | 01C | 01D | |AS-T793*-ME| VAX 11/785 CONSOLE | | F | F | J | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869D | POWER CONTROLLER (U.S.) | H | H | H | H | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869E | POWER CONTROLLER (EUR) | F | F | F | F | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | | | | | | | | E H | E |11/785-|11/785 |11/785-|11/785 | | See previous page | V I | C |TW003 |TW005 |MK006 |MK006 | | | I S | O | | | | | | | S T | | | | | | | | I O | N | | | | | | | O R | O | | | | | | | N Y |___|_______|_______|_______|_______| | | | D | 12/ |2/ |12/ |9/ | | | | A | 17/ | 26/ | 1/ | 29/ | | | | T | 84 | 86| 86 | 86| |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | 11/785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| -12- ______________________________________________________________________________ | OPTION NAME | R | | | | | | 11785-AE-AK | E | 3B | | | | |________________________________________|_V_|_______|_______|_______|_______| | PART NO. | DESCRIPTION | |11785 | CPU | |___________|________________________________________________________________| | | | | | | | | | | | | | | |KA785 | CPU KERNAL | D | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |KC785-FA,FC| CONSOLE | A | | | | | FD | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |MS780-H | MEMORY | B | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |FP785 | FLOATING POINT ACCELERATOR | E | | | | |___________|________________________________|_______|_______|_______|_______| | | | +| | | | |DW780 | UNIBUS ADAPTOR | 01,C1 | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |VMS | VIRTUAL MEMORY OPERATING SYSTEM| 4.0 | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | |EVNDX | VAX DIAGNOSTIC INDEX | 18 | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |SSUXXX.WCS | SUPERSTAR MICROCODE | 1D | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869D | POWER CONTROLLER (U.S.) | H | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |869E | POWER CONTROLLER (EUR) | F | | | | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | | | | | | | | E H | E |11/785 | | | | | See previous page | V I | C |TW006 | | | | | | I S | O | | | | | | | S T | | | | | | | | I O | N | | | | | | | O R | O | | | | | | | N Y |___|_______|_______|_______|_______| | | | D |12/ | | | | | | | A | 01/ | | | | | | | T | 86| | | | |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | 11/785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| - 13 - 5.2 KA785 ________________________________________________________________________________ | OPTION NAME | | | KA785 | | |____________________________|_________________________________________________| | | | KA785-TW001 KA785 Revision "00" | | ----------- | | This is the initial introduction of the Revision Matrix for the KA785 | | revision "00". Rev "00" is equivalent to "A". | | | | This represents the minimum option revision level at FCS, June, 1984. | | | | KA785-TW002 KA785 Revision "B" | | ----------- | | Update RM Document as a result of the following ECO. This changes the rev | | of the KA785 to "B". | | | | ECO #M7460-TW003 | | | | PROBLEM: Intermittent system crashes and machine checks associated with | | cache parity errors. | | | | CORRECTION: Delay parity and parity enable signals one cycle to prevent | | system crashes. | | | | NEW PART REV: M7460 at rev "C". | | | | QUICK CHECK: Check for 74S51 in spare location E10. | | | | FCO #11785-R-0001 | | | | | | KA785-A-MK003 KA785 Revision "C" | | ------------- | | Option Revision C resulted in no change to the KA785 Hardware. The | | purpose of this revision identifier is to allign this document with the | | 11785 System level Rebvision Matrix. | | | | KA785-MK004 KA785 Revision "D" | | ----------- | | | | Update RM as a result of the following ECOs. This changes the Rev of the | | KA785 to revision "D". | | | | | | | | | | | | | | | |------------------------------------------------------------------------------| | | | | | | | | KA785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_______________| - 14 - _______________________________________________________________________________ | OPTION NAME | | | KA785 | | |____________________________|________________________________________________| | | | ECO No. New Part Rev | | | | M7460-MK005 Rev D1,D2,D3 | | M7468-MK003 M7468-YA Rev A1 | | M7468-MK03A No Change | | M7468-MK03B No Change | | M7469-MK005 M7469-YA Rev A1,A2 | | M7469-MK05A No Change | | M7470-MK006 M7470-YA Rev A1,A2 | | M7471-MK001 M7471-YA Rev A1 | | M7471-MK01A No Change | | M7472-MK003 Rev C1,C2 | | 7020579-MK006 REV A1 | | | | PROBLEM: (1) VA/VIBA, AMUX Sext paths fail worse case timing analysis. | | (2) Signal integrity and timing problems with BMUX select lines.| | (3) Cache parity error output is unstable and may result in | | lost micro traps or false CPE micro traps. | | FCO: 11785-03-R003 | | | | All 11/785s are being upgraded with this FCO. | | | | COMMENTS: | | | | Note 1: M7468-YA, M7469-YA, M7470-YA and M7471-YA modules cannot be | | mixed in a machine with M7468-00 through M7471-00 modules. | | M7472 Rev C1,C2 modules are backwards compatible with -00 | | variants. | | | | Once backplanes are reworked to Rev A1,ONLY -YA VARIANTS CAN | | BE USED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | ------------------------------------------------------------------------------| | | | | | | | | KA785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|______________| - 15 - _____________________________________________________________________________ | OPTION NAME | R | | | | | | KA785 | E | *00 | B | C | D | |________________________________________|_V_|_______|_______|_______|________ | PART NO. | DESCRIPTION | | | | |___________|________________________________|_______|_______|_______|_______| | M7459 | TRS | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7460 | SBL | B | C | C | D | |___________|________________________________|_______|_______|_______|_______| | M7461 | SBH | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7462 | CAM | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7463 | CDM | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7464 | TBM | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7465 | IDP | C | C | C | C | |___________|________________________________|_______|_______|_______|_______| | M7466 | IRC | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7467 | DBP | A | A | A | A | |___________|________________________________|_______|_______|_______|_______| | M7468 | DEP | B | B | B | N/A | |_ - or - __|________________________________|_______|_______|_______|_______| | M7468-YA | DEP | N/A | N/A | N/A | A | |___________|________________________________|_______|_______|_______|_______| | M7469 | DDP | C | C | C | N/A | |__- or -___|________________________________|_______|_______|_______|_______| | M7469-YA | DDP | N/A | N/A | N/A | A | |___________|________________________________|_______|_______|_______|_______| | M7470 | DCP | B | B | B | N/A | |__- or -___|________________________________|_______|_______|_______|_______| | M7470-YA | DCP | N/A | N/A | N/A | A | |___________|________________________________|_______|_______|_______|_______| | M7471 | DAP | B | B | B | N/A | |__- or -___|________________________________|_______|_______|_______|_______| | M7471-YA | DAP | N/A | N/A | N/A | A | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | | | |11785- | | | | E H | E | | |TW005 | | | *Revision 00 is equiv.to "A" | V I | C |KA785- |KA785- |KA785- | KA785-| | | I S | O |TW001 |TW002 |MK003 | MK004 | | | S T | | | | | | | | I O | N | | | | | | | O R | O | | | | | | | N Y |___|_______|_______|_______|_______| | | | D |31/ |13/ | | | | | | A | AUG/ | NOV/ | | | | | | T | 84| 84| | | |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | KA785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| - 16 - _____________________________________________________________________________ | OPTION NAME | R | | | | | | KA785 (Continued) | E | 00 | B | C | D | |________________________________________|_V_|_______|_______|_______|________ | PART NO. | DESCRIPTION | | | | |___________|_________________________________________________________________ | M7472 | CEH | B | B | B | C | |___________|________________________________|_______|_______|_______|_______| | M7473 | ICL | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7474 | CLK | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7475 | JCS | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7476 | USC | B | B | B | B | |___________|________________________________|_______|_______|_______|_______| | M7477 | CIB | D | D | D | D | |___________|________________________________|_______|_______|_______|_______| |70-14956-00| POWER SUPPLY (U.S) | * | * | * | * | |___________|________________________________|_______|_______|_______|_______| |70-14956-01| POWER SUPPLY (EUROPE) | * | * | * | * | |___________|________________________________|_______|_______|_______|_______| |70-20579-01| BACKPLANE | C | C | C | - | |___________|________________________________|_______|_______|_______|_______| |70-20579-02| BACKPLANE | - | - | - | A1 | |___________|________________________________|_______|_______|_______|_______| | H7100-A | POWER SUPPLY (U.S.) | H | H | H | H | |___________|________________________________|_______|_______|_______|_______| | H7100-B | POWER SUPPLY (EUROPE) | H | H | H | H | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | | | |11785- | | | | E H | E | | |TW005 | | | | V I | C |KA785- |KA785- |KA785- |KA785- | | | I S | O |TW001 |TW002 |MK003 |MK004 | | | S T | | | | | | | | I O | N | | | | | | | O R | O | | | | | | | N Y |___|_______|_______|_______|_______| | | | D |31/ |13/ | | | | | | A | AUG/ | NOV/ | | | | | | T | 84| 84| | | |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | KA785 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| -17- 5.3 MS780-E/F +------------------------------------------------------------------------------+ | OPTION NAME | | | MS780-E/F | | |____________________________|_________________________________________________| | | | MS780E-TW001 MS780E Revision "00" | | ------------ | | This is the initial introduction of the Revision Matrix for the MS780-E/F. | | This RM represents the minimum Option Revision level at FCS, June, 1984. | | (00 is equivalent to "A1") | | | | MS780E-MK002 Documentation Change Only- not applicable to this Doc. | | ------------ | | MS780E-MK003 MS780E Revision "B1" | | ------------ | | | | Update RM as a result of the following ECOs. This changes the rev of the | | MS780E to "B1". | | | | ECO No. New Part Revision | | | | M8375-MK003 D1 | | M8376-MK006 E1 | | | | Problem: Component vendors unable to deliver 74S373 ICs which function | | to specification. | | Correction: Replace all 74S373 components with 74F373 components. | | | | Quick Check: M8375 - 74F373 (19-21010) @ E1 | | M8376 - 74F373 (19-21010) @ E7 | | | | Comments: Installation of these ECOs will change the SID minor field for | | 780s and 785s to "B" (ie, 7B) | | | | MS780E-MK004 | | ------------ | | Update RM as a result of the following ECO. This changes the rev of the | | MS780E to "C1". | | | | ECO NO. New Part Revision | | ------- ----------------- | | | | M8376-MK007 F1 | | | | Problem: VMS logs what appears to be a CORRECTED MEMORY ERROR into the | | Error Logger on the 11785 system when performing a WARM RESTART | |Correction: Delay signal. | | | | | | | -------------------------------------------------------------------------------| | | | | | | | | MS780-E/F | | | d | i | g | i | t | a | l | REVISION MATRIX | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_______________| - 18 - _____________________________________________________________________________ | OPTION NAME | R | | | | | | MS780-E/F | E | *00 | B | C | | |________________________________________|_V_|_______|_______|_______|________ | PART NO. | DESCRIPTION | | | | |___________|_________________________________________________________________ | | | | | | | | M8373 | MEMORY ARRAY | B | B | B | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M8375 | MEMORY CONTROLLER | C | D1 | D1 | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M8376 | SBI INTERFACE | E | E1 | F1 | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |70-19729 | BACKPLANE | A | A | A | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | VMS | VIRTUAL MEMORY OPERATING SYS | 3.5 | 3.5 | 3.5 | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | EVNDX | VAX DIAGNOSTIC INDEX | 16 | 16 | 16 | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | | | | | | | * OPTION REV "00" EQUIV TO "A"| E H | E | | | | | | 1.All revision data ind. MIN. | V I | C |MS780-E|MS780-E|MS780-E| | | useable version. | I S | O |TW001 |MK002 |MK004 | | | and M8376 are "CS" Revs | S T | | | | | | | | I O | N | | | | | | Rev B | O R | O | | | | | | Part Rev implemented on | N Y |___|_______|_______|_______|_______| | M8375 and M8376. | | D |19/ |1/ |6/ | | | 2.H/W rev data for Opt.Rev 00 | | A | SEP/ | JUN/ | JUN/ | | | spec. "CS" or "WL" rev. Data| | T | 85| 86| 88| | | for Opt. Rev.B and up spec. | | E | | | | | | Part Revision. | | | | | | | |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| -19- 5.4 MS780-H +------------------------------------------------------------------------------+ | OPTION NAME | | | MS780-H | | |____________________________|_________________________________________________| | | | MS780H Revision "00" | | | | This is the initial introduction of option revision control on the MS780-H | | option and represents the minimum revision levels at FCS (February 1985). | | Option Rev "00" equivalent to "A". | | | | MS780H-MK001 MS780H Revision "B" | | ------------ | | This is the initial introduction of the Revision Matrix for the MS780-H. | | This changes the revision of the MS780H to "B" and incorporates the | | following ECOs: | | | | ECO No. New Part Revision | | | | M8375-MK003 D1 | | M8376-MK006 E1 | | | | Problem: Component vendors unable to deliver 74S373 ICs to spec. | | Correction: Replace all 74S373 components with 74F373 components. | | | | Quick Check: M8375 - E11 is 19-21010-01 | | M8376 - E7 is 19-21010-01 | | | | Comments: FCO MS780-H-R001; all MS780H options in 11/780 and 11/785 | | systems should be upgraded with this FCO. | | | | Changes system rev as follows: | | | | 11/780 to Rev *B (i.e. 7B, 8B) | | 11/785 to Rev *B (i.e. 2B, 3B) | | | | MS780H-MK002 | | ------------ | | Update RM for following ECOs. These change the rev of the MS780H to "C1". | | | | ECO No. New Part Revision | | ------- ----------------- | | M8376-MK007 F1 | | | | Problem: VMS logs what appears to be a CORRECTED MEMORY ERROR into the | | Error Logger on the 11785 system when performing a WARM RESTART | |Correction: Delay signal. | | | | MS780H-MK003 | | ------------- | | Update RM to reflect a new nylon relock nut which was added on 2/15/88. | | Changes revision of MS780H to "C1". | -------------------------------------------------------------------------------| | | | | | | | | MS780-E/H | | | d | i | g | i | t | a | l | REVISION MATRIX | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_______________| - 20 - _____________________________________________________________________________ | OPTION NAME | R | | | | | | MS780-H | E | *00 | B | C | | |________________________________________|_V_|_______|_______|_______|________ | PART NO. | DESCRIPTION | | | | |___________|_________________________________________________________________ | | | | | | | | M8374 | MEMORY ARRAY | A | A | A | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M8375 | MEMORY CONTROLLER | C | D | D | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M8376 | SBI INTERFACE | E | E1 | F1 | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |70-19729 | BACKPLANE | A | A | A | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | VMS | VIRTUAL MEMORY OPERATING SYS | 4.0 | 4.0 | 4.0 | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | EVNDX | VAX DIAGNOSTIC INDEX | 18 | 18 | 18 | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | | | | | | | 1. Rev 00 | E H | E | | | | | | Revision listed for M8374, | V I | C | No |MS780-H|MS780-H| | | M8375 and M8376 are "CS" | I S | O | |MK001 |MK002 | | | revisions. | S T | | ECO | | | | | | I O | N | | | | | | Rev B | O R | O | | | | | | Part Rev implemented on | N Y |___|_______|_______|_______|_______| | M8374,M8375 & M8376 modules| | D | |11/ |6/ | | | | | A | | NOV/ | JUN/ | | | 2. Rev is WL revision. | | T | | 86 | 86| | |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| - 21 - 5.5 FP785 ________________________________________________________________________________ | OPTION NAME | | | FP785-AA, AB | | |____________________________|_________________________________________________| | | | FP785-TW001 FP785 Revision "00" | | ----------- | |This is the initial introduction of the Revision Matrix for the FP785. | | | |This R.M. represents the minimum option revision level "00" at FCS, June 1984.| |Minimum EVNDX to support Rev 00 is 16 which went out with each system/upgrade.| |Diagnostic updates for Field Service were distributed in Release 17 of EVNDX. | | | |FP785-TW002 FP785 Revision "B" | |---------- | |Update the RM as a result of the following ECO. This changes the rev of | |the FP785 to "B". | | | |ECO# M7544-TW002 | | | |PROBLEM: Floating Point results are unpredictable when using MULD2 or MULD3 | | | |CORRECTION: Disable MULD2 and MULD3 in the Floating Point Accelerator. | | | |FP785-TW003 FP785 Revision "C" | |----------- | |Update the RM as a result of the following ECOs. These change the rev of | |the FP785 to "C". | | | |ECOs: M7540-TW002 | | M7541-TW003 | | M7542-TW002 | | M7544-TW003 | |NEW PART REVS: | | M7540 at rev "C" | | M7541 at rev "D" | | M7542 at rev "C" | | M7544 at rev "D1,"DD1" or "D2" | | | |PROBLEM: The Floating Point gives incorrect answers when using double | | precision floating point instructions. | | | |QUICK CHECK: M7540-check location E8 for 74S194. | | M7541-check location E2 for 74S194. | | M7542-check location E3 for 74S194. | | M7544-check for no wire on pin 9 of E65. | | | |FCO #FP785-M-00C1 | | | | | -------------------------------------------------------------------------------| | | | | | | | | | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_______________| -22 - ________________________________________________________________________________ | OPTION NAME | | | FP785-AA, AB (Continued) | | |____________________________|_________________________________________________| |FP785-TW004 FP785 Revision "D". | |----------- | |Update the R.M. as a result of the following ECO. This changes the rev of | |the FP785 to "D". | | | |ECO#M7541-TW004 | | | |PROBLEM: FML, M7542 module exhibits failures running EVKAC at slow clock.| | The failing instruction is Poly D. | | | |NEW PART REV: M7541 at rev "E". | | | |QUICK CHECK: Check for 74F08 on M7541 in location E88. | | | |COMMENTS: An FCO will be implemented in the near future to upgrade all | | FP785s from "C" TO "D". | | | | Note: Most E.Q. kits for FCO FP785-M00C1 contain rev "E1" of the M7541 | | and do not require upgrading. However, it is important to check | | the revision of the M7541 module before implementing the upcoming | | FCO. | | | |FP785-MK005 FP785 Revision "E" | |----------- | | | | Update RM as a result of the following ECO. This changes the revision of the| | FP785 to "E1". | | | | ECO No. New Part Revision | | ------- ----------------- | | M7542-MK003 D1 | | M7540-TW003 D1,D2 | | 7020579-MK004 D1,D2 | | | | Problem: Poor signal/noise ratio may result in errors if FP is run at slow | | clock. A Poly precision enhancement was not predictable. | | Quick Check: M7542 - 74F08 at location E5 | | M7540 - Wire from E37.4 to E37.8 | 7020579 - wire on pin B26M2 | | | | Comments: FCO FP785-E-R003; should be installed in all FP785 options. | | | | Note 1: Current version of Micro4 (ETKAU) may fail (Section 7 Test 5D) | | after installation of the FCO. Updated version available Q2FY86. | | | | Note 2: Quick check should be performed for all M7540 modules; some Rev | | D1 modules were shipped by manufacturing without the wire in that | | location. | -------------------------------------------------------------------------------| | | | | | | | | | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_______________| - 23 - _______________________________________________________________________________ | OPTION NAME | R | | | | | | | | FP785-AA, AB | E | *00 | B | C | D | E1 | | |________________________________________|_V_|_____|_____|_____|_____|_____|___| | PART NO. | DESCRIPTION | | | | |___________|__________________________________________________________________| | | | | | | | | | | M7540 | FNM | B | B | C | C | D | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | | M7541 | FMH | B | B | D | E | E | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | | M7542 | FML | B | B | C | C | D | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | | M7543 | FAD | A | A | A | A | A | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | | M7544 | FCT | B | C | D | D | D | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | |70-20579-01| CPU BACKPLANE | C | C | C | C | D | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | | H7100-A | POWER SUPPLY | J | J | J | J | J | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | | H7100-B | POWER SUPPLY | J | J | J | J | J | | |___________|________________________________|_____|_____|_____|_____|_____|___| |ETKAU | | 2.0 |2.1 | 2.0 | 2.0 | 3.0 | | |AS-T791*-DE| MICRO 4 DIAGNOSTIC | B | C |B,D,E|B,D,E| F | | |___________|________________________________|_____|_____|_____|_____|_____|___| | | | | | | | | | | | | | | | | | | |___________|________________________________|_____|_____|_____|_____|_____|___| | NOTES: | R | | | | | | | | |* Option Rev "00" equiv to "A" | E H | E | | | | | | | | | V I | C |FP785|FP785|FP785|FP785:FP785| | | | I S | O |TW001|TW002|TW003|TW004|MK005| | | | S T | | | | | | | | | | I O | N | | | | | | | | | O R | O | | | | | | | | | N Y |___|_____|_____|_____|_____|_____|___| | | | D |31/ |13/ |1/ |1/ | | | | | | A |AUG | NOV/| MAY | MAY | | | | | | T | /84| 84| /85| /85| | | |_______________________________|________|_E_|_____|_____|_____|_____|_____|___| | | | | | | | |TITLE | | | | | | | | | | | FP785-AA, AB | | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | | DOCUMENT | | | |___|___|___|___|___|___|___|_______________________________|__________|_______| - 24 - 6.0 APPENDIX This section contains charts for options which can be part of an 11/785 configuration but do not have revision matrices today. Unlike the revision matrices which show only minimum useable revisions, these charts show all compatible revisions. (They were taken from the Field Service 11/780 Rev Con Document). 6.1 KC785 OPTION LEVEL REVISION CHART --------------------------------- KC785 A ------------------------------------------------- 11/03 (KD11, BA11, DLV11) N MSV11-DE (M8044) (24K 16 BIT MOS MEM) E M7946 (RX01 CONTROLLER) E M9400-YE (LSI11 BUS) L 7016482-01 (RX01 FLOPPY DR ASSEM) S DLV11-E (M8043) (REMOTE CONSOLE) M 6.2 MS780C 11780 MOS MEMORY (16KB ARRAY) MS780C OPTION LEVEL REVISION CHART __________________________________ MS780C- 1.0 1.A 1.B _______________________________________________________ M8210 *, A *,A,B *,A,B,C M8212 A A,B,C A,B,C,D M8213 D D,E D,E M8214 C C C,D _______________________________________________________ Backplane 7013625 E1 WIRELIST *,A *,A - MS780C-1.0 OPTION REVISION DESCRIPTION _____________________________________ o Creation date is Sept. 15, 1978 o This is the initial introduction of Option Level control for the MS780C and defines the minimum revision level necessary to support the first release of VMS (Release 1.0). o All modules with previous revisions to those listed under MS780C-01 must be updated to the current revision level. o M8214 A,B module revisions are operational with VMS Release 1.0 unless the system contains RM03 disks or 1Mbaud DMC11's. In those cases excessive data lates occur with the RM03 disks or line drop outs occur with the DMC11's. o M8214 C module revision solves the above problems but must be used with M8275 D in the RH780 options. - 25 - MS780C-1.A OPTION REVISION DESCRIPTION _______________________________________ o Creation date is April 13, 1979 o Change to M8213 board to get rid of problem where three longwords are returned for a quad read. Problem occurs intermittently, only when running ECC tests at fast clock. o M8213 eco should be installed along with M8271,M8273,M9044 eco's. Together these four changes make the 11/780 level 2A. MS780C-1.B OPTION REVISION DESCRIPTION ______________________________________ o Creation date January 12, 1981 o Fixes problem of intermittant or consistent failures when memory is expanded beyond 4 arrays - M8212 module. o M8212 modules with National Semiconductor chips will not exhibit the problem. o ECO 70-13625 TW005 to the backplane helps alleviates some single bit errors seen in the field. - 24 - - 26 - 6.3 DW780 ________________________________________________________________________________ | OPTION NAME | | | DW780 (ALL VARIANTS) | | |____________________________|_________________________________________________| | | | DW780-TW008 DW780 REVISION "01" | | ----------- | | This is the initial introduction of the revision matrix for the DW780. | | This RM represents the current option rev. level shipping from mfg. in | | June, 1984. Rev 01 in this doc. is the same as 1B (latest revision) | | defined in the CSSE 11780 revision control document. | | | | (Note: Any future option revision changes will apply to Dec Std. 68, | | i.e. Revision 01 is equivalent to B1.) | | Minimum EVNDX to support Rev 01 is Rel 16. | | | | DW780-TW009 DW780 Revision "C1" | | ----------- | | Update the RM as a result of the following ECO. This changes the rev of | | the DW780 to "C1". | | | | ECO # M8271 TW007 | | | | PROBLEM: Unibus time-outs occur on devices that use buffer data paths. | | | | CORRECTION: Fixes a unibus timeout problem exhibited when running UDA50s. | | | | NEW PART REV: M8271 at revs F1, F2 (2 etches) | | | | QUICK CHECK: 74S74 at Loc E118 | | | | FCO #DW780-S00C1 (being implemented on DW780s that exhibit this problem.) | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | -------------------------------------------------------------------------------| | | | | | | | | DW780 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_______________| - 27 - _____________________________________________________________________________ | OPTION NAME | R | | | | | | DW780- ALL VARIANTS | E | 01 | C1 | C1 | | |________________________________________|_V_|_______|_______|_______|_______| | PART NO. | DESCRIPTION | | DW780 | UNIBUS ADAPTOR ASSEMBLY | |___________|________________________________________________________________| | | | | | | | | M8270 | USI | C | C | C | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M8271 | UCB | E | F | F | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M8272 | UMB | D | D | D | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M8273 | UAI | C | C | C | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M9042 | UPC | A | A | A | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | M9044 | UBT | C | C | C | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | 7013626 | BACKPLANE | E | E | E | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | EVNDX | VAX DIAGNOSTIC INDEX | 16 | 16 | *18 | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |H7100-A** | POWER SUPPLY (U.S.) | J | J | J | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | |H7100-B** | POWER SUPPLY (EUROPE) | J | J | J | | |___________|________________________________|_______|_______|_______|_______| | | | | | | | | | | | | | | |___________|________________________________|_______|_______|_______|_______| | NOTES: | R | | | | | | |*Release 18 required for VMS | E H | E | | | | | | Vers.4 | V I | C |DW780- |DW780- |DW780- | | | | I S | O |TW008 |TW009 |TW009 | | |**Only required when purchased | S T | | | | | | | as separate option. | I O | N | | | | | | | O R | O | | | | | | | N Y |___|_______|_______|_______|_______| | | | D |19/ |21/ |21/ | | | | | A | SEP/ | FEB/ | FEB/ | | | | | T | 84| 85| 85| | |_______________________________|________|_E_|_______|_______|_______|_______| | | | | | | | |TITLE | | | | | | | | | | DW780 | | | d | i | g | i | t | a | l | REVISION MANAGEMENT | | | | | | | | | | DOCUMENT | | |___|___|___|___|___|___|___|__________________________________|_____________| - 28 - 6.4 RH780 OPTION LEVEL REVISION CHART _________________________________ RH780 - 04 AA1 ------------------------------------------------------------------------ M8275 D D M8276 E E M8277 H H M8278 C C ------------------------------------------------------------------------ M9041 * * Backplane 7013627 H H Power Supply (U.S.) H7100-A J J Power Supply (Europe) H7100-B J J RH780 B1 ------------------------------------------------------------------------- M8274 A1 M8275 D M8276 E1 M8278 C ------------------------------------------------------------------------- M9041 * Backplane: 7013627 H Power Supply (U.S.) H7100-A J Power Supply (Europe) H7100-B J -29 - RH780-04 OPTION REVISION DESCRIPTION ------------------------------------ o Creation date is July 1, 1981. o Corrects the following problems: 1. Data transfers at 2.2 MB/SEC overrun the data buffers. This revision must be installed prior to installation of an RP07. 2. When doing odd byte transfers on the TU78, the last byte is dropped. o The two module ECO's (M8276 & M8277) must be installed in conjunc- tion with each other. RH780-AA1 OPTION REVISION DESCRIPTION ------------------------------------- o This option revision implements part rev on the RH780 option. Note that compatible revisions for this rev are identical to Rev 04. o Rev AA1 (04) (i.e. RH780s containing M8277 modules) should be used on RH780s that are not running high speed RP07s. RH780-B1 OPTION REVISION DESCRIPTION ------------------------------------ o Creation date is December 1983 - manufacturing implementation. o M8274 module replaces M8277 module in this revision. M8274 fixes problem with data being lost when running RP07s at high speed. An FCO was implemented in November 1983 to: (1) replace M8277s with M8274s when running high speed RP07s, and (2) add the M8274 to all RH780 CD kits. EQ-01217-01 - contents: 1 M8274 module. o 11/780 systems may contain mixtures of RH780-Rev AA1 (04) and RH780-Rev B1 with no compatibility problems. - 30 - 6.5 DR780 OPTION LEVEL REVISION CHART --------------------------------- DR780- 01 ---------------------------------------------------------- M8296 * M8297 * M8298 A,B M8299 (D1) Microcode T392B ---------------------------------------------------------- M9046 * (Power Supply-U.S.) H7100-A J (POWER SUPPLY-Europe) H7100-B J A revision marked with an * indicates the initial marking on the modules at FCS. DR780-01 OPTION REVISION DESCRIPTION ------------------------------------ o Creation date was May 1983. o Change to the M8299 module to fix a timing problem. ECO also requires change to the DR780 microcode. FCO will be implemented in Q1FY84. FCO will be module rework and involves replacement of 2 socketed FPLAs. o Microcode was changed as a result of this ECO. New part number is AS-T392B-DE. This was released in VAX Diagnostic Release 10 (January 1983) and will be included in the E.Q. kit for this FCO. o NOTE THAT A SUPPLEMENTAL FCO WAS BE DONE IN OCTOBER 1983 TO CHANGE THE PART REV OF THE M8299 FROM "C1" TO "D1". THIS WAS ONLY TO CORRECT THE REVISION; THERE WAS NO CHANGE IN THE CONTENT OF THE FCO. - 31 - 6.6 MA780 11780 MULTIPORT MEMORY MA780 OPTION LEVEL REVISION CHART --------------------------------- MA780- 01 -------------------------------------------------------- M8210 A,B,C M8212-YA D M8258 B M8259 D M8260 A,B M8261 B -------------------------------------------------------- M9045 A Power Supply: MA780-A: 70-14957-00 (U.S.) B 70-14957-01 (Europe) B MA780-C: H7100-A (U.S.) J H7100-B (Europe) J MA780-01 OPTION REVISION DESCRIPTION ------------------------------------ o Creation date is April 1, 1982. o Changes to the M8258 and M8259 modules - FCO MA780-R-0001. FCO implementation is module rework. o This revision of the MA780 option is required for the 11782. An existing 11780 containing an MA780 that is upgraded to an 11782 MUST have the FCO installed. - 32 - 6.7 CI780 COMPUTER INTERCONNECT CI780 OPTION LEVEL REVISION CHART --------------------------------- CI780 C1 D1 E1,(**EE1) F1 ------------------------------------------------------------------- L0100 *** D1,(B2*) D1,(B2*) D1,(B2*) D,(B2*),E L0118 *** B1,B2 B1,B2 B1,B2 B1,B2 L0101 H1 H1 H1,**HH1 J,K L0102 C1 C1,D1 C1,D1 C,D L0104 C,C1,D1 C,C1,D1 C,C1,D1 C,D Microcode CI780.BIN Rev 3.0 Rev 4.0 Rev 5.0 Rev 7,8 AS-T213*-ME F G H J,O **Rev 6.0 BACKPLANE 70-17654 A A A A ------------------------------------------------------------------ POWER SUPPLY 70-14956-00 (U.S.) * * * * 70-14956-00 (Europe)* * * * * (Note) "B2" is being marked on "B" etch and is equal to "D1". ** (Note) Rev 6.0 ucode and the "HH1" module are used only if CI780-EE1-I-005 FCO needs to be installed making the CI780 Rev EE1. *** (Note) L0118 is enhanced L0100 replacement, and can be used as "universal spare". L0118 is required to support >16 node functionality. CI780-01 OPTION REVISION DESCRIPTION ------------------------------------ o Creation date was October 1983 - manufacturing implementation. o This revision change involves ECOs to the L0100, L0101 and L0102 modules as follows: L0100-TW003 - Constant carrier on one CI path may prevent use of the other path. L0101-TW004 - 1.Lost CI packet under heavy load. 2.Incorrect microcode resulting in a loop at address 24D L0102-TW003 - Intermittant local store parity errors. o FCO was implemented to upgrade all CI780 options and CD kits. Availability was November 1983. Note that all CI780s in the cluster must be upgraded at the same time. o New microcode (CI780.BIN Version 2) required for this FCO. This is included in FCO kit and can be ordered under PN AS-T213D-ME. o Diagnostics EVGAA and EVGAB updated in Release 14 (available from SDC November 5, 1983). New version for both is 1.1. These are included in the FCO kit - can be ordered under PN AS-T599B-ME. - 33 - CI780-C1 REVISION SUMMARY ------------------------- o Creation date was November 1984 - mfg. ship date. o CI780-C1 ECOs: ECO # Part Rev Problem/Correction Quick Check ----- -------- ------------------ ----------- L0101-TW006 H1 1. Virtual circuits E76 is are closed by un- 23-271F3-00 recognized commands. 2. Virtual circuit closure due to micro confusion. 3. Port hangs due to conflict in queue access. Correction is V3.0 CI microcode. NOTE THAT L0101 REV H1 AND CI780.BIN REV 3.0 MUST BE USED TOGETHER. o FCO to upgrade all CI780s implemented in December 1984. EQ-01310-01 ROMS for L0101 module EQ-01310-02 11/780 Console, AS-T213F-ME (CI780.BIN Rev 3.0) EQ-01310-03 11/785 Console, AS-T793C-ME (CI780.BIN Rev 3.0) o This FCO is part of VAXcluster Rev D1. Other FCOs that could be needed to bring the Cluster to Rev D1 are: FCO H/W Rev CI750-R-00B1 Rev B1 HSC50-R-0006 Rev C1 RA80X-R-0002 Rev B0 RA60-R-0003 Rev A5 These FCOs should be installed prior to or during VMS V4.0 installation. Note that although VMS Release notes state that earlier revisions are acceptable, i.e. will probably work, engineering and product management have determined that the customer needs all these FCOs for acceptable cluster performance under VMS V4.0. Details of Cluster Rev D1 requirements were sent to all branch managers. Contact your regional/country FCO coordinator for ordering info on these FCOs. Refer to the VAXCluster Revision Control document for more information on Cluster Rev D1 requirements. o Minimum requirement for CI functional diagnostics (EVGAA, EVGAB) is 1.1. - 34 - CI780-D1 REVISION SUMMARY ------------------------- o Creation date was April, 1985 - Manufacturing ship date. o Option Revision "D1" involves a change to the microcode only. A functional problem was discovered in VAX cluster testing. The CI780 did not conform to Architectual Specification producing "MISCELLANEOUS ERRORS TYPE 12 & 13" causing VMS CI--PORT RE-INITS introduced by V3.0 microcode. o An FCO was implemented to upgrade all CI780 options to Rev "D1". Rev 4 microcode can be obtained in two ways: 1. Over the ENET - Copy VOLKS::CLUSTER$REV:CI780.BIN + 2. Order EQ kits as follows: To upgrade from: To: Order: --------------- -- ----- CI780 Rev 01 CI780 Rev D1 EQ-01344-01 (ROMS) (ucode Rev 2) (ucode Rev 4) EQ-01344-02 (780 ucode) EQ-01344-03 (785 " ) CI780 Rev C1 CI780 Rev D1 EQ-01344-02 (780 ucode) (ucode Rev 3) (ucode Rev 4) EQ-01344-03 (785 " ) + This file contains the latest ucode rev. CI780-E1 REVISION SUMMARY ------------------------- o Creation date was September 1985 (from Manufacturing). o Option Revision "E1" involves a change to the CI microcode only. New microcode is Rev 5. Problem fixed: extensive in-house testing of very large VAXclusters showed that under specific conditions the CI780 interface will sometimes incorrectly recover from CI error conditions. o An FCO is being implemented to upgrade all CI780 options to Rev "E1". Rev 5 microcode can be obtained in two ways: 1. Over the ENET - Copy VOLKS::CLUSTER$REV:CI780.BIN + 2. Order EQ kits as follows: From: To: Order: ---- -- ----- CI780 Rev 01 CI780 Rev E1 EQ-01344-01 (ROMS) (ucode Rev 2) (ucode Rev 5) EQ-01365-01 (780 ucode) EQ-01365-02 (785 " ) (ucode Rev 3) (ucode Rev 5) EQ-01365-02 (785 " ) CI780 Rev E1 CI780 Rev E1 EQ-01365-01 (780 ucode) (ucode Rev 4) (ucode Rev 5) EQ-01365-02 (785 " ) - 35 - CI780-F1 REVISION HISTORY ------------------------- o Creation date is July 1986 - Manufacturing implementation date. This revision change involved an ECO to the L0101 module bringingthe module rev to "J1". *PROBLEM/CORRECTION L0101-MK009 1.numerous functional errors ("arbitration timeout", internal queue retry error"). 2.Need a variable sanity timer. 3.Need to check the "valid" bit when referencing a cache buffer description. 4.Correct documentation errors. Correction is V7.0 CI microcode and 6 proms. Note that the L0101 rev J1 and CI780.bin rev 7.0 must be used together. An FCO is being implemented to upgrade all CI780's (CI780-F1-I-005). L0101 MK010 - 1. Paths crossed, "reqid" sent on path a, response on path B. 2. Clock the transmit enable flop correctly to prevent cluster hung. This ECO involves two etch cuts and two wire adds. It brings the L0101 to rev "K1". Revs "J1" and "K1" are both acceptable in CI780 rev "F1". CI780-AA/AB REVISION H1 ----------------------- o Creation date is June 1987. o This revision changed the CI780 from "F" to "H". o This revision change involved an eco to the L0100 module bringing the module rev to "E". PROBLEM/CORRECTION L0100-MK006 1. Original 140 mhz clock and associated hardware has tendency to drift off frequency. 2. Existing wires caused by eco #mk005 cause extensive manufacturing costs. the following corrections are implemented by this eco: 1. Change 140 mhz crystal to new hybrid oscillator (p/n 18-23940-01) and delete unnecessary hardware. 2. Phase in new etch to remove wire's on module. - 35 - L0100-MK005 1. Major problems in the interface which would be highly visible in large cluster configurations. These problems include the following: A) CI 20 self directed packet problem. B) Arbitration problem. C) SYNC detect pal could latch up under a flood condition. D) Implementation of the xtend hdr jumper was incorrect. E) Acknowledge turn-around and basic slot time causing excessive collisions on the wire. F) Correct trailer time to meet the spec. 1. The following corrections are implemented by this eco: A) CRC byte counter reset now with (ILIB ABORT + INIT FNC L) * - (ILIB INIT L). B) First try flag is now incorporated to provide real arbitration where the node is now synchronized on loss of carrier and will obey the rules of dual round robin arb. C) New pal will be incorporated. D) XTEND hdr jumper now functional. E) Install a change to make alter delta time jumper select A BASIC SLOT TIME OF 7 TO 10 CLOCK TICKS. *QUICK CHECK - (Module REV E1) L0100 with wire from a) e65.13 and E177.13 B) E65.11 and E177.9 DIAGNOSTIC EVCGD, V1.2 required for this eco. Updated in diagnostic Release 26 (EVNDX 26). L0100 jumper W1 (module rev E1) or S3 (module rev E2) indicates the following conditions: A) Jumper (W1) installed between e177 socket pins 11 and 12, or switch (s3) open, disabled: 1) This makes the L0100 downwards compatible with rev D L0100 modules, by maintaining the basic slot count to the existing count of seven (7) ticks, acknowledge turn-around remains the same as the original rev D L0100's, and the trailer extension is not enabled. With these eliminated, the eco'ed L0100 (rev E) will maintain form, fit and function as the non-eco'ed (rev D) modules. However, it should be noted that the following fixes will still be installed and be functional in rev E, while in the disabled position: new sync detect pal, CI20 fix, xtend hdr jumper, and XMIT status bit 3. - 36 - B) Jumper (W1) installed between E177 socket pins 9 and 10, or switch (s3) closed, enabled: 1) Basic slot time is now implemented to ten (10) ticks. 2) Ack turn-around change fully implemented. 3) Trailer extension by two (2) bytes, fully functional. 4) Arbitration and first try flag full implementation. 5) New SYNC detect pal, xtend hdr jumper, CI20 and XMIT status bit 3, will still be fully functional as above. CI780-AA/AB REVISION J1 ----------------------- o Creation date is May 1988. o This revision changed the CI780 from "H" to "J". o This revision documents the introduction of the L0118 in place of the LO100. PROBLEM/CORRECTION - N/A QUICK CHECK - Verify LO118 is installed. DIAGNOSTIC RELEASE 28 (EVNDX 28). Contains the minimum usuable diagnostics for the L0118 module. \\VAX_REV_MATRIX