Difference between revisions of "DH11 asynchronous serial line interface"
(→Main unit: +M791 Berg conn card) |
m (New cat scheme) |
||
(6 intermediate revisions by 2 users not shown) | |||
Line 37: | Line 37: | ||
|Break Control Register || DHBRCR || 760034 | |Break Control Register || DHBRCR || 760034 | ||
|- | |- | ||
− | |Silo Status Register || DHSSR || | + | |Silo Status Register || DHSSR || 760036 |
|} | |} | ||
Line 57: | Line 57: | ||
{{16bitoctal-bitout}} | {{16bitoctal-bitout}} | ||
− | === | + | ===760036: Silo Status Register (DHSSR)=== |
{{16bit-header}} | {{16bit-header}} | ||
| Rsvd || Unused || colspan=6 | Fill || colspan=2 | XMem || colspan=6 | Alarm | | Rsvd || Unused || colspan=6 | Fill || colspan=2 | XMem || colspan=6 | Alarm | ||
Line 103: | Line 103: | ||
* M7279 - FIFO buffer | * M7279 - FIFO buffer | ||
− | * M7280 (2) - Octal | + | * M7280 (2) - Octal [[Universal Asynchronous Receiver/Transmitter|UART]]s |
and a number of single-width cards: | and a number of single-width cards: | ||
Line 175: | Line 175: | ||
==Later implementations== | ==Later implementations== | ||
− | The DH11 was later re-implemented as the [[DHU11]], which was | + | The DH11 was later re-implemented as the [[DHU11 asynchronous serial line interface|DHU11]], which was not programmatically identical to the DH11, but had the same capabilities. (It also had the input timer, discussed above.) It fitted on a single [[DEC card form factor|hex-height]] card, which plugged into a [[Modified UNIBUS Device|MUD]] slot. |
− | For the [[QBUS]], the [[DHV11]] and [[DHQ11]] ( | + | For the [[QBUS]], the [[DHV11 asynchronous serial line interface|DHV11]] and [[DHQ11 asynchronous serial line interface|DHQ11]] (the former was mostly programmatically identical to the DHU11; the latter could be set to exactly emulate either a DHU11 or a DHV11) appeared; they only supported 8 lines each (via two quad breakout panels), however. |
==External links== | ==External links== | ||
+ | * [http://www.bitsavers.org/pdf/dec/unibus/EK-ODH11-OP-002_DH11_Asynchronous_16-line_Multiplexer_Users_Manual_Sep76.pdf DH11 asynchronous 16-line multiplexer user's manual] (EK-ODH11-OP-002) | ||
+ | * [http://www.bitsavers.org/pdf/dec/unibus/EK-0DH11-MM-003_Apr75.pdf DH11 asynchronous 16-line multiplexer maintenance manual] (EK-ODH11-MM-003) | ||
+ | * [http://www.bitsavers.org/pdf/dec/unibus/DH11_EngrDrws_Jul76.pdf DH11 Engineering Drawings] | ||
* [http://woffordwitch.com/McNamaraDH11.asp The Development Of The DH11 Multiplexer] | * [http://woffordwitch.com/McNamaraDH11.asp The Development Of The DH11 Multiplexer] | ||
− | [[Category: UNIBUS Serial Interfaces]] | + | [[Category: UNIBUS Asynchronous Serial Interfaces]] |
Latest revision as of 01:27, 19 February 2023
The DH11 asynchronous serial line interface is a UNIBUS peripheral which provides up to 16 asynchronous serial lines. Output used DMA (with each line having its own buffer pointer and count); on input a 64-character FIFO buffer made over-runs unlikely.
As a UNIBUS device, it was usable on the PDP-11 and VAX computers. Although it first appeared very early on in the lifetime of the PDP-11, it was extremely powerful and flexible, and remained an option for a very long time.
The parameters for each line:
- separate input and output baud rates
- character length (5-8 bits)
- stop bits (1, 1-1/2 and 2)
- parity (odd, even, none)
could be set dynamically (unlike, for example, the DJ11, which set parameters for groups of lines using jumpers)
Fourteen supported baud rates ranged from 50 to 9600, along with 0 (to disable a line); two additional speeds were available with optional clock FLIP CHIPs. A 'break' condition on the line (i.e. continuous assertion) could also be generated and detected.
For modem control, a single DM11-BB Modem Control Option per DH11, mounted in the main DH11 backplane along with the rest of the DH11 cards, was required. (The DM11-BB is logically a separate device, albeit one housed in the DH11.)
Contents
Device registers
The registers LPR through BCR are replicated, with one for each line in the device; the 'Line' field in the SCR indicates which one is currently available.
Register | Abbreviation | Address |
---|---|---|
System Control Register | DHSCR | 760020 |
Next Received Character Register | DHNRCR | 760022 |
Line Parameter Register | DHLPR | 760024 |
Current Address Register | DHCAR | 760026 |
Byte Count Register | DHBCR | 760030 |
Buffer Active Register | DHBAR | 760032 |
Break Control Register | DHBRCR | 760034 |
Silo Status Register | DHSSR | 760036 |
The addresses shown are for the first DH11 in a system; additional ones are normally set to be at 760040, 760060.
760020: System Control Register (DHSCR)
TI | SI | OIE | SIE | MCLR | NXM | MAINT | CNXM | RI | RIE | MEX | Line | ||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
760022: Next Received Character Register (DHNRCR)
DPR | OVR | FRM | PAR | Line | Data | ||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
760024: Line Parameter Register (DHLPR)
Echo | HFD | TSpeed | RSpeed | ODD | PAR | Unused | 2SB | Length | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
760036: Silo Status Register (DHSSR)
Rsvd | Unused | Fill | XMem | Alarm | |||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Initial implementation
The original implementation took an entire double system unit backplane, containing multiple cards (see list below). It came in 'earlier' and 'later' versions.
In the 'early' versions, modular 'line conditioning' units allowed support of either 20mA or EIA RS-232 serial lines; these were installed in a separate rack-mounted dual-height DM11 distribution panel backplane (which required its own independent power supply).
In the 'later' units, to reduce the cost, line conditioning was performed on boards mounted in the main DH11 backplane, and a rack-mounted passive H317-B distribution panel provided connectors for individual lines.
These 'later' versions only supported EIA-type line conditioning (with or without modem control); to add modem control, a different implementation of the DM11-BB was required (one which did the EIA level conversion on the control lines internally).
Versions
The 'early' versions of the DH11 were:
- DH11-AA - Basic unit (110VAC), requires line conditioning units in addition
- DH11-AB - Telegraph line version (see below)
- DH11-AC - Basic unit (220VAC), requires line conditioning units in addition
The 'later' versions were:
- DH11-AD - EIA level conversion, modem control
- DH11-AE - EIA level conversion, no modem control
For the telegraph line option, the line conditioning backplane and its power supply were omitted, and up to two DH11's were connected to a DC08CS Telegraph Converter Panel.
Main unit
The 'basic' DH11 included the following hex-width boards:
- M7277 - Transmit scanner
- M7278 - Registers and byte count
- M7288 - Line parameters control
- M7289 - Receiver scanner
a dual-width and two quads:
- M7279 - FIFO buffer
- M7280 (2) - Octal UARTs
and a number of single-width cards:
- M4540 - Crystal clock
- M7360 - Priority selector
- M796 - UNIBUS master control
- M7821 (2) - Interrupt control (transmit. receive, and NPR)
- M405 - Baud clock (optional; 2)
- M791 - Berg connector header connector card
Board locations (as seen from the board insertion side of the backplane, not the wire-wrap pin side, as is common in DEC documentation) are:
Connector | ||||||
---|---|---|---|---|---|---|
Slot | A | B | C | D | E | F |
1 | UNIBUS In | Reserved for DM11-BB | ||||
2 | M7821 | M796 | Reserved for DM11-BB | |||
3 | M7278 | |||||
4 | M7277 | |||||
5 | M7289 | |||||
6 | M7821 | M405 (optional) | M7280 | |||
7 | M7360 | M971 (cable) | M7280 | |||
8 | M7288 | |||||
9 | UNIBUS Out | M7279 | M405 (optional) | M4540 |
An optional M794 maintenance card could be plugged into the slot normally used by the M971, for testing.
The 'later' versions of the DH11 both included:
- M5906 EIA conversion module
which occupied a dual slot (used by an M7360 Priority Selector card and an M971 Cable Connector card, used to connect the DH11 to the line conditioning units, in the 'early' versions).
The -AD version, which included a 'later' DM11-BB for modem control, also used:
- M7807 - Mux and Bus Control
- M7808 - Mux and Modem Scan Control
These boards fitted into the same slots occupied by the DM11-BB boards in the 'early' versions (the M7807 in slot 1, the M7808 in slot 2).
Distribution panels
The rack-mounted passive distribution panel initially used in the 'later' versions was the H317-B passive distribution panel, initially created for the DJ11, which mounted directly into a standard 19" rack, and contained 16 DB-25P connectors.
It was connected to the DH11 with a pair of BC08S cables, which carried the 'main' signals (data, etc - i.e. non-modem control); these cables were thus required for both 'later' versions. For the modem control signals (Carrier Detect, etc) used with the DH11-AD, four BC08R cables were used.
Later, the H3007 8-line EIA distribution panel, designed for use in later DEC cabinets with improved EMI characteristics, was introduced; the H3007 fits into the standard panel 21cm x 10cm cutout found in these systems.
Design flaw
Some time after it was introduced, it became apparent that there was a design flaw associated with the 'silo alarm' functionality. This mechanism allowed increased processing efficiency by allowing multiple input characters to be processed with a single interrupt; it involved a register (the 'Silo Alarm Level') which contained a count of the number of characters required in the input buffer (the 'silo') before an interrupt was generated.
The problem is that if less characters than that arrive, and then no more, an interrupt is never generated. So, code which uses higher levels for the silo alarm has to periodically check to see if less characters than that have arrived, and are waiting.
(Apparently, the designer admitted that this was a flaw; he indicated that there should have been a timer, such that after the first character entered the silo, if the silo was still non-empty after the timer ran out, an interrupt would be generated.)
Later implementations
The DH11 was later re-implemented as the DHU11, which was not programmatically identical to the DH11, but had the same capabilities. (It also had the input timer, discussed above.) It fitted on a single hex-height card, which plugged into a MUD slot.
For the QBUS, the DHV11 and DHQ11 (the former was mostly programmatically identical to the DHU11; the latter could be set to exactly emulate either a DHU11 or a DHV11) appeared; they only supported 8 lines each (via two quad breakout panels), however.