CI750 Computer Interconnect Interface: Difference between revisions

From Computer History Wiki
Jump to navigationJump to search
Vaxorcist (talk | contribs)
m Vaxorcist moved page CI750 to CI750 Computer Interconnect Interface: Make page name more "speaking"
m Move to more specific cats, add some links
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
The CI750 is the [[CI]] adapter for the [[VAX-11/750]].
The '''CI750 Computer Interconnect Interface''' is the [[Computer Interconnect|CI]] interface for the [[CPU/Memory Interconnect]] (CMI) [[bus]] of the [[VAX-11/750]].


It connects to one CI node directly, or to multiple CI nodes using the [[SC008|SC008 Star Coupler]].
It connects to one CI node directly, or to multiple CI nodes using the [[SC008 Star Coupler]].


It consists of:
It consists of:
* The [[CMI]] card L0009 - VAX-11/750 CCI (CMI Cluster Interconnect Module), that is placed into the VAX-11/750 CMI backplane.
 
* The [[CMI]] card L0009 - VAX-11/750 CCI (CMI Cluster Interconnect Module), that is placed into the VAX-11/750 CMI [[backplane]].
* The CIPA (CI Port Adapter) Unit, made of:
* The CIPA (CI Port Adapter) Unit, made of:
** H9542 - 40" Medium System Cabinet Kit
** H9542 - 40" Medium System Cabinet Kit, containing:
** 70-20407 - CIPA Power Supply
*** 70-20407 - CIPA Power Supply
** 54-15555 - CIPA Backplane
*** xx-xxxxx - CIPA Mounting Box ([[DEC part number]] still unknown), containing:
** L0100 - ILI (I Link Interface Module)
**** 54-15555 - CIPA Backplane, containing:
** L0101 - IPB (I Packet Buffer Module)
***** L0100 - ILI (I Link Interface Module), or
** L0400 - CDP (Data Path Module)
***** L0118 - ILI (I Link Interface Module) for up to 32 Nodes
***** L0101 - IPB (I Packet Buffer Module)
***** L0400 - CDP (Data Path Module)
 
The CI750 uses the same CIPA (CI Port Adapter) as the [[CIBCI]] - [[VAX Bus Interconnect|VAXBI]] CI Interface, 1st generation
 
The L0009 in the VAX-11/750 and the CIPA are connected using the 70-19602 - L0009 to CIPA Cable.
 
CI750 revisions are covered in the [[VAX-11/750 & VAX-11/751 Revision Control]] document.
 
==External links==
 
* [http://www.bitsavers.org/pdf/dec/vax/handbook/VAX_Hardware_Handbook_Volume_1_1986.pdf VAX Hardware Handbook Volume 1] - the CI750 is covered in some detail in Chapter 11 (pp. 503-520 of the PDF)
* [http://bitsavers.org/pdf/dec/vax/750/MP01647_CI750_198307.pdf CI750 Field Maintenance Print Set] (MP01647-01)


Both units are connected using the 70-19602 - L0009 to CIPA Cable.
[[Category: CMI]]
[[Category: Computer Interconnect Interfaces]]

Latest revision as of 14:47, 15 May 2024

The CI750 Computer Interconnect Interface is the CI interface for the CPU/Memory Interconnect (CMI) bus of the VAX-11/750.

It connects to one CI node directly, or to multiple CI nodes using the SC008 Star Coupler.

It consists of:

  • The CMI card L0009 - VAX-11/750 CCI (CMI Cluster Interconnect Module), that is placed into the VAX-11/750 CMI backplane.
  • The CIPA (CI Port Adapter) Unit, made of:
    • H9542 - 40" Medium System Cabinet Kit, containing:
      • 70-20407 - CIPA Power Supply
      • xx-xxxxx - CIPA Mounting Box (DEC part number still unknown), containing:
        • 54-15555 - CIPA Backplane, containing:
          • L0100 - ILI (I Link Interface Module), or
          • L0118 - ILI (I Link Interface Module) for up to 32 Nodes
          • L0101 - IPB (I Packet Buffer Module)
          • L0400 - CDP (Data Path Module)

The CI750 uses the same CIPA (CI Port Adapter) as the CIBCI - VAXBI CI Interface, 1st generation

The L0009 in the VAX-11/750 and the CIPA are connected using the 70-19602 - L0009 to CIPA Cable.

CI750 revisions are covered in the VAX-11/750 & VAX-11/751 Revision Control document.

External links