Difference between revisions of "TM02 magtape controller"
(better term) |
m (→See also: +TM03) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
A TM02 can control up to 8 drives, although the TM02 and drives count as only a single MASSBUS device. The TM02 controller connects to all the drives over a 'slave bus'; all the drives are identical (unlike in the [[TM11 magtape controller|TM11]]/[[TU10 magtape drive|TU10]] system. | A TM02 can control up to 8 drives, although the TM02 and drives count as only a single MASSBUS device. The TM02 controller connects to all the drives over a 'slave bus'; all the drives are identical (unlike in the [[TM11 magtape controller|TM11]]/[[TU10 magtape drive|TU10]] system. | ||
+ | |||
+ | The TU16/TM02 with an [[RH11 MASSBUS controller|RH11]] MASSBUS interface is denominated as a '''TJU16'''; with the [[RH70 MASSBUS controller|RH70]] MASSBUS interface of the [[PDP-11/70]], it is denominated as a '''TWU16'''. | ||
==Implementation== | ==Implementation== | ||
Line 34: | Line 36: | ||
''To be added.'' | ''To be added.'' | ||
+ | |||
+ | ==See also== | ||
+ | |||
+ | * [[TM03 magtape controller]] | ||
+ | |||
+ | ==External links== | ||
+ | |||
+ | * [http://www.bitsavers.org/pdf/dec/magtape/tu16/EK-TJU16-MM-002_TJU16_Magnetic_Tape_Subsystem_Maintenance_Manual_Apr75.pdf EK-TJU16-MM-002 TJU16 magnetic tape subsystem maintenance manual] - covers the TM02 in detail | ||
+ | * [http://www.bitsavers.org/pdf/dec/magtape/tu16/EK-TWU16-MM-001_TWU16_Magnetic_Tape_Subsystem_Maintenance_Manual_Dec75.pdf EK-TWU16-MM-001 TWU16 magnetic tape subsystem maintenance manual] - ditto | ||
[[Category: MASSBUS Devices]] | [[Category: MASSBUS Devices]] |
Latest revision as of 17:27, 22 May 2022
The TM02 magtape formatter is a MASSBUS device controller, used with 1/2" magnetic tape drives; supported drives include the TU16 and TE16 (both at 45 inches per second). It can handle 800 bits/inch (NRZI) and 1600 bits/inch (PE - Phase Encoded).
A TM02 can control up to 8 drives, although the TM02 and drives count as only a single MASSBUS device. The TM02 controller connects to all the drives over a 'slave bus'; all the drives are identical (unlike in the TM11/TU10 system.
The TU16/TM02 with an RH11 MASSBUS interface is denominated as a TJU16; with the RH70 MASSBUS interface of the PDP-11/70, it is denominated as a TWU16.
Implementation
The TM02 is implemented as a set of boards, all of which plug into a custom hex-high nine-slot backplane, usually mounted in a special box in the first tape drive rack. The modules include two hex-size boards, seven quad-size modules, and six dual-high modules.
The hex modules are:
- M8909 - MASSBUS Interface
- Bit Fiddler
- M8906 for use with a PDP-11
- M8914 for use with a PDP-10
The quad modules are:
- 3 x M8901 - Data Sync (PE)
- M8902 - Tape Control (PE)
- M8903 - Tape Control Common Mode
- M8904 - Tape Control (NRZI)
- M8905 - Maintenance Register
The dual modules are:
- M8907 - Control and Write Drivers
- M8908-YA
- M8908
- 3 x M5903 or M5903-YA
The first three are the drive slave bus interface; the last three are the MASSBUS interface.
Drive bus
To be added.
See also
External links
- EK-TJU16-MM-002 TJU16 magnetic tape subsystem maintenance manual - covers the TM02 in detail
- EK-TWU16-MM-001 TWU16 magnetic tape subsystem maintenance manual - ditto