Difference between revisions of "PC11 High-Speed Paper-Tape Reader/Punch Control"
From Computer History Wiki
(Fairly complete) |
(No difference)
|
Revision as of 15:04, 1 September 2018
The PC11 is the UNIBUS device controller for the PC05 paper tape high-speed reader/punch.
It uses programmed I/O, with interrupts when it is ready for/with more data.
It is a single quad card, which plugs into an SPC slot. A pair of cables (one for the reader, one for the punch - to support reader-only or punch-only options) connect it to the device.
Contents
Registers
The device has four control registers, which can be configured to any four sequential word locations in the I/O page; it is normally configured to addresses 777550-777556:
Register | Abbreviation | Address |
---|---|---|
Paper-Tape Reader Status Register | PRS | 777550 |
Paper-Tape Reader Buffer Register | PRB | 777552 |
Paper-Tape Punch Status Register | PPS | 777554 |
Paper-Tape Punch Buffer Register | PPB | 777556 |
In the register contents (below), bits which are read/write or unused are shown in normal font, those which are read-only are in italics, and write-only in bold.
Reader Status Register (PRS)
ERR | Unused | BUSY | Unused | DONE | INT ENB | Unused | RDR ENB | ||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Reader Buffer Register (PRB)
Unused | Input Data | ||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Punch Status Register (PPS)
ERR | Unused | RDY | INT ENB | Unused | |||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Punch Buffer Register (PPB)
Unused | Output Data | ||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
The PPB does not respond to 'read' cycles on the UNIBUS.