[[Image:M7819.jpg|thumb|right|200px|M7819]] | [[Image:M7819.jpg|thumb|right|200px|M7819]] | ||
− | |||
− | + | The '''DZ11''' was a [[UNIBUS]] 8 port [[asynchronous serial line]] mux card for [[Digital Equipment Corporation|DEC]] computers. | |
− | + | It was a [[DEC card form factor|hex]] card, which plugged into an [[Small Peripheral Controller|SPC]] [[backplane]] slot, and used [[programmed I/O]]. The [[EIA RS-232 serial line interface|EIA]] version was the M7819, and the [[20mA current loop serial line interface|20mA]] was the M7814. The EIA model can operate with [[modem]]s. | |
− | * | + | On the M7819, a [[flat cable]] led from a [[Berg connector]] on the card to an EIA distribution panel holding 16 DB25 connectors, enough for two DZ11 cards. |
− | * | + | |
− | *BC05W 50 conductor signal cable | + | Common accessories for the EIA version are: |
− | *H325 test connector | + | |
− | *H3271 test connector. | + | * Cable Box assembly |
+ | * H317-E EIA distribution panel | ||
+ | * BC05W 50 conductor signal cable | ||
+ | * H325 test connector (single line) | ||
+ | * H3271 staggered test connector | ||
+ | |||
+ | For the 20mA, substitute the: | ||
+ | |||
+ | * H317-F 20mA distribution panel | ||
+ | * BC08S 40 conductor signal cable | ||
+ | * H3190 staggered test connector. | ||
+ | |||
+ | [[Category: UNIBUS Serial Interfaces]] |
Revision as of 04:36, 11 December 2018
The DZ11 was a UNIBUS 8 port asynchronous serial line mux card for DEC computers.
It was a hex card, which plugged into an SPC backplane slot, and used programmed I/O. The EIA version was the M7819, and the 20mA was the M7814. The EIA model can operate with modems.
On the M7819, a flat cable led from a Berg connector on the card to an EIA distribution panel holding 16 DB25 connectors, enough for two DZ11 cards.
Common accessories for the EIA version are:
- Cable Box assembly
- H317-E EIA distribution panel
- BC05W 50 conductor signal cable
- H325 test connector (single line)
- H3271 staggered test connector
For the 20mA, substitute the:
- H317-F 20mA distribution panel
- BC08S 40 conductor signal cable
- H3190 staggered test connector.