Difference between revisions of "CIBCI"

From Computer History Wiki
Jump to: navigation, search
m (Link to the follow-up adapter CIBCA-A added)
(Microcode info added)
(2 intermediate revisions by the same user not shown)
Line 16: Line 16:
 
***** L0400 - CDP (Data Path Module)
 
***** L0400 - CDP (Data Path Module)
  
Cabling:
+
The CIBCI uses the same CIPA (CI Port Adapter) as the [[CI750 Computer Interconnect Interface|CI750 VAX-11/750 CI Interface]]
 +
 
 +
The CIBCI was superseded by the [[CIBCA-A]] - VAXBI CI Interface, 2nd generation.
 +
 
 +
==Software==
 +
All three 1st Generation CI Adapters:
 +
* [[CI780 Computer Interconnect Interface|CI780 VAX-11/780 CI Interface]]
 +
* [[CI750 Computer Interconnect Interface|CI750 VAX-11/750 CI Interface]]
 +
* CIBCI
 +
share the same Microcode: CI780.BIN
 +
 
 +
==Cabling==
 
* The T1017 and T1018 cards are connected using the 17-01029-01 and 17-01029-02 BCI cables.  
 
* The T1017 and T1018 cards are connected using the 17-01029-01 and 17-01029-02 BCI cables.  
 
* The CI Port Adapter (CIPA) bus cable assembly, part number 17-01027-01, connects the VAXBI backplane to the CIPA backplane.
 
* The CI Port Adapter (CIPA) bus cable assembly, part number 17-01027-01, connects the VAXBI backplane to the CIPA backplane.
  
 +
==Documentation==
 
The three CIBCI [[Field Change Order|FCO]]s:
 
The three CIBCI [[Field Change Order|FCO]]s:
 
* [[FCO CIBCI-I001]],  
 
* [[FCO CIBCI-I001]],  
Line 25: Line 37:
 
* [[FCO CIBCI-I003]]
 
* [[FCO CIBCI-I003]]
 
describe problems with and solutions for the CIBCI.  
 
describe problems with and solutions for the CIBCI.  
 
The CIBCI is superseded by the [[CIBCA-A]] - VAXBI CI Interface, 2nd generation.
 
  
 
==External links==
 
==External links==

Revision as of 12:51, 27 February 2023

The CIBCI is the VAXBI to CI Interface, 1st Generation Adapter for the VAXBI VAX Computers.

It connects to one CI node directly, or to multiple CI nodes using the SC008 Star Coupler.

It consists of:

  • The BI-CI Adapter Control (BAC) Card T1017, that is placed into the VAX VAXBI Backplane
  • The BI-CI Adapter Data (BAD) Card T1018, that is placed into the VAX VAXBI Backplane
  • The CIPA (CI Port Adapter) Unit, made of:
    • H9542 - 40" Medium System Cabinet Kit, containing:
      • 70-20407 - CIPA Power Supply
      • xx-xxxxx - CIPA Mounting Box (Order number still unknown), containing:
        • 54-15555 - CIPA Backplane, containing:
          • L0100 - ILI (I Link Interface Module), or
          • L0118 - ILI (I Link Interface Module) for up to 32 Nodes
          • L0101 - IPB (I Packet Buffer Module)
          • L0400 - CDP (Data Path Module)

The CIBCI uses the same CIPA (CI Port Adapter) as the CI750 VAX-11/750 CI Interface

The CIBCI was superseded by the CIBCA-A - VAXBI CI Interface, 2nd generation.

Software

All three 1st Generation CI Adapters:

share the same Microcode: CI780.BIN

Cabling

  • The T1017 and T1018 cards are connected using the 17-01029-01 and 17-01029-02 BCI cables.
  • The CI Port Adapter (CIPA) bus cable assembly, part number 17-01027-01, connects the VAXBI backplane to the CIPA backplane.

Documentation

The three CIBCI FCOs:

describe problems with and solutions for the CIBCI.

External links