Difference between revisions of "DZQ11 asynchronous serial line interface"
(Fairly complete) |
(→Implementation: later variant dist panel) |
||
Line 5: | Line 5: | ||
==Implementation== | ==Implementation== | ||
− | Physically, it was a [[DEC card form factor|dual]] card, the M3106; a cable plugged into a [[Berg connector]] header on the card led the lines out of the computer. The pin assignments in the Berg header are mirrored, so that if the mating Berg connector is plugged in backwards, the only result is to invert the line numbering. | + | Physically, it was a [[DEC card form factor|dual]] card, the M3106; a cable plugged into a 40-pin [[Berg connector]] header on the card led the lines out of the computer. The pin assignments in the Berg header are mirrored, so that if the mating Berg connector is plugged in backwards, the only result is to invert the line numbering. |
− | + | ===Cabling=== | |
− | An alternative to the BC11U consisted of a [[flat cable]] from | + | One choice for the cabling is the special BC11U-25 cable; it consisted of 4 separate round cables, from the Berg connector, to individual [[EIA RS-232 serial line interface#Connectors|DB25 male connectors]] (DB-25P) wired as DTEs. |
+ | |||
+ | An alternative to the BC11U consisted of a [[flat cable]] from the Berg connector to another on a 4-port [[distribution panel]] ([[DEC part numbers|DEC part number]] 70-19964), holding DB25 male connectors. (The distribution panel may be recognized by the part number on its [[printed circuit board|PCB]], 50-15419; the part number for the complete assembly is 54-15420.) | ||
+ | |||
+ | A later variant on that added [[static filter]]s on a separate card (PCB part number 50-19890; the part number for the whole is 54-19891-01) which is plugged into the Berg header on the above card, and provides another Berg header for the flat cable to plug into. The part number for the complete assembly is 70-02657-01. | ||
==Device registers== | ==Device registers== |
Revision as of 17:36, 6 January 2021
The DZQ11 asynchronous serial line interface was a QBUS four port asynchronous serial line mux card for DEC computers; a re-implementation of the DZV11 (with which it is program compatible and plug compatible ). Like the original UNIBUS DZ11, it used used programmed I/O, and thus could present a considerable load on the CPU when running a high speed line.
A 64-entry FIFO buffer silo was provided on the input side. The DZQ11 could operate with full-duplex modems. It provided program-set baud rates (up to 19800 baud), but not split speed. Break could be detected or generated on each line.
Contents
Implementation
Physically, it was a dual card, the M3106; a cable plugged into a 40-pin Berg connector header on the card led the lines out of the computer. The pin assignments in the Berg header are mirrored, so that if the mating Berg connector is plugged in backwards, the only result is to invert the line numbering.
Cabling
One choice for the cabling is the special BC11U-25 cable; it consisted of 4 separate round cables, from the Berg connector, to individual DB25 male connectors (DB-25P) wired as DTEs.
An alternative to the BC11U consisted of a flat cable from the Berg connector to another on a 4-port distribution panel (DEC part number 70-19964), holding DB25 male connectors. (The distribution panel may be recognized by the part number on its PCB, 50-15419; the part number for the complete assembly is 54-15420.)
A later variant on that added static filters on a separate card (PCB part number 50-19890; the part number for the whole is 54-19891-01) which is plugged into the Berg header on the above card, and provides another Berg header for the flat cable to plug into. The part number for the complete assembly is 70-02657-01.
Device registers
Register | Abbreviation | Address |
---|---|---|
Control and Status Register | CSR | 760100 |
Receiver Buffer Register* | RBUF | 760102 |
Line Parameter Register* | LPR | 760102 |
Transmit Control Register | TCR | 760104 |
Modem Status Register | MSR | 760106 |
Transmit Data Register | TDR | 760106 |
The RBUF and LPR share an address, as do the MSR and TDR: the RBUF is read only, and the LPR is write only; the MSR is read only, and the TDR is write only. Registers marked with a '*' are word-width only, no byte operations.
The addresses shown are for the first DZ11 in a system (provided that there are no other devices in the floating device address space); additional ones are normally set to be at 760110, 760120, etc.
Control and Status Register (CSR)
TRDY | TIE | SA | SAE | Unused | Tx Line | RDONE | RIE | MSE | CLR | MAINT | Unused | ||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
- TRDY - Transmitter Ready
- TIE - Transmitter Interrupt Enable
- SA - Silo Alarm
- SAE - Silo Alarm Enable
- Tx Line - Line ready to transmit
- RDONE - Received Done
- RIE - Receiver Interrupt Enable
- MSE - Master Scan Enable
- CLR - Clear input FIFO, CSR and UARTs
- MAINT - Maintenance loopback enabled
Receiver Buffer Register (RBUF)
DV | OVR | FRERR | PERR | Unused | Rx Line | RBUF | |||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Line Parameter Register (LPR)
Unused | RXON | Speed | ODDP | PAREN | STOP | CLEN | Unused | Line | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Transmit Control Register (TCR)
Unused | DTR | Unused | Line Enabled | ||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Modem Status Register (MSR)
Unused | CD | Unused | RI | ||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Transmit Data Register (TDR)
Unused | Break | TBUF | |||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 09 | 08 | 07 | 06 | 05 | 04 | 03 | 02 | 01 | 00 |
Further reading
- DZQ11 User Guide, EK-DZQ11-UG-002
- DZQ11 Technical Manual, EK-DZQ11-TM-001