RH11 MASSBUS controller
The RH11 MASSBUS controller (generally the RH11-AB model) allowed the interconnection of MASSBUS devices such as the RP04 to systems with a UNIBUS, primarily on PDP-11's.
Second UNIBUS
The RH11 contains connectors and circuitry for two separate UNIBUSes; the second UNIBUS is primarily used on systems with multi-port memory, such as the PDP-11/45.
The registers in the RH11 are only accesssible from the 'first' UNIBUS (UNIBUS 'A'); likewise, interrupts of the CPU are only possible via UNIBUS 'A'. The RH11 can be set under software control to do DMA data transfers on either the first or second UNIBUS (UNIBUS 'B').
If no CPU is connected to UNIBUS 'B', an M9300 terminator at the start of the bus can be configured to do NPR bus grants. A jumper allows the RH11 to do block transfers on UNIBUS 'B' without going through an arbitration cycle; the 'A' UNIBUS has a mode where it can do two DMA cycles per grant.
18-bit mode
The RH11 has the capability to operate in 18-bit mode; in this mode, the PA and PB UNIBUS parity lines are used for data bits 16 and 17. The PDP-15 and KS10 made use of this capability, the latter with the RH11-C model.
(The difference between the -AB and -C is currently unknown; the latter used the M7294-YA instead of the M7294 as in the former. Since that card is the MASSBUS data buffer and control, it's likely related to the MASSBUS.)
Note that 18-bit mode is only available on the 'B' UNIBUS (which must be selected) if a jumper is removed; see Section 4.16 "Logic Diagram DBCE", pg. 4-28 (65 of the PDF) in the "RH11-AB Option Description" for details.
Registers
The RH11 contains 4 registers, plus a share of a fifth; they are
- RHCS1 - Control and Status 1 (shared)
- RHWC - Word Count
- RHBA - Bus Address
- RHCS2 - Control and Status 2
- RHDB - Data Buffer (for maintenance)
As is standard for the MASSBUS, all the other device registers are in the device.
Hardware
The RH11 consisted of a double system unit backplane (below) into which plugged a number of cards:
Two of them hex-sized:
- M7294 - DBC - Data Buffer and Control
- M7295 - BCT - Bus Control
Two dual-sized cards containing controller logic:
- M7296 - CSR - Control and Status
- M7297 - PAC - Parity Generation and Checking
Three dual-height M5904 MASSBUS transceiver modules.
Optionally one or two single-height cards:
- M688 - UNIBUS Power Fail Driver
The RH11 backplane also contained three SPC slots in otherwise-unused slots.
Backplane layout
Board locations (as seen from the board insertion side of the backplane, not the wire-wrap pin side, as is common in DEC documentation) are:
Connector | ||||||||
---|---|---|---|---|---|---|---|---|
Slot | A | B | C | D | E | F | ||
1 | UNIBUS A In | M7297 Parity | M7296 Control/Status | |||||
2 | M7295 Bus Control | |||||||
3 | M7294 Data/Buffer Control | |||||||
4 | Unused | M5904 Transceiver | M688 - UNIBUS B Power Fail | Unused | ||||
5 | Unused | M5904 Transceiver | M688 - UNIBUS A Power Fail | Unused | ||||
6 | Unused | M5904 Transceiver | Unused | |||||
7 | UNIBUS B Out | SPC | ||||||
8 | UNIBUS B In | SPC | ||||||
9 | UNIBUS A Out | SPC |