CIBCI Computer Interconnect Adapter

From Computer History Wiki
Jump to: navigation, search

The CIBCI is the 1st Generation VAXBI to CI Interface, for VAX computers with a VAXBI.

It connects to one CI node directly, or to multiple CI nodes using the SC008 Star Coupler.

It consists of:

  • The BI-CI Adapter Control (BAC) Card T1017, that is placed into the VAX VAXBI Backplane
  • The BI-CI Adapter Data (BAD) Card T1018, that is placed into the VAX VAXBI Backplane
  • The CIPA (CI Port Adapter) Unit, made of:
    • H9542 - 40" Medium System Cabinet Kit, containing:
      • 70-20407 - CIPA Power Supply
      • xx-xxxxx - CIPA Mounting Box (Order number still unknown), containing:
        • 54-15555 - CIPA Backplane, containing:
          • L0100 - ILI (I Link Interface Module), or
          • L0118 - ILI (I Link Interface Module) for up to 32 Nodes
          • L0101 - IPB (I Packet Buffer Module)
          • L0400 - CDP (Data Path Module)

The CIBCI uses the same CIPA (CI Port Adapter) as the CI750 VAX-11/750 CI Interface

The CIBCI was superseded by the CIBCA-A - VAXBI CI Interface, 2nd generation.

Software

All three 1st Generation CI Adapters:

share the same Microcode: CI780.BIN

Cabling

  • The T1017 and T1018 cards are connected using the 17-01029-01 and 17-01029-02 BCI cables.
  • The CI Port Adapter (CIPA) bus cable assembly, DEC part number 17-01027-01, connects the VAXBI backplane to the CIPA backplane.

Documentation

The three CIBCI FCOs:

describe problems with and solutions for the CIBCI.

External links