MicroVAX 3100 series: Difference between revisions

From Computer History Wiki
Jump to navigationJump to search
m VAX formal group _pages_ only go in their VAX formal group _categories_
m →External links: Manx mirror of Antonio's stuff, MDS is gone
 
(2 intermediate revisions by one other user not shown)
Line 15: Line 15:
All models of the series supported [[Small Computer System Interface|SCSI]] for [[mass storage]], as well as [[Ethernet]] and several [[asynchronous serial line]]s. Additional [[main memory]], asynchronous serial lines, and [[synchronous serial line]]s, were available as options.
All models of the series supported [[Small Computer System Interface|SCSI]] for [[mass storage]], as well as [[Ethernet]] and several [[asynchronous serial line]]s. Additional [[main memory]], asynchronous serial lines, and [[synchronous serial line]]s, were available as options.


A desktop [[mounting box]] was used across most of the 3100 line; the Models 88 and 98 used mini-tower packaging. All models could run either [[VMS]] or [[ULTRIX-32]].
A desktop [[mounting box]] was used across most of the 3100 line; the Models 88 and 98 used mini-tower packaging. All models could run [[VMS]] and the older ones (presumably up to and including model 40) [[ULTRIX-32]], too.


The models in the series were:
The models in the series were:
Line 53: Line 53:
** [https://www.vaxhaven.com/images/b/b7/EK-A0519-MG.001.pdf MicroVAX 3100 Platform Options] (EK-A0519-MG.001)
** [https://www.vaxhaven.com/images/b/b7/EK-A0519-MG.001.pdf MicroVAX 3100 Platform Options] (EK-A0519-MG.001)
** [https://www.vaxhaven.com/images/4/49/EK-A0716-IN-B01.pdf MicroVAX 3100 Model 85/95 Installation Information] (EK–A0716–IN.B01)
** [https://www.vaxhaven.com/images/4/49/EK-A0716-IN-B01.pdf MicroVAX 3100 Model 85/95 Installation Information] (EK–A0716–IN.B01)
* [https://manx-docs.org/collections/antonio/dec/a0574hr1.pdf MicroVAX 3100 Platform CPU Reference Information] (EK-A0574-HR.001)
* [https://vt100.net/mirror/antonio/a0574hr1.pdf MicroVAX 3100 Platform CPU Reference Information] (EK-A0574-HR.001)
* [https://manx-docs.org/collections/mds-199909/cd1/vax/a0519udd.pdf MicroVAX 3100 Platform Options Supplement] (EK-A0519-UD.D01)
* [https://www.filibeto.org/dec/mds/mds-1999-09/cd1/vax/a0519udd.pdf MicroVAX 3100 Platform Options Supplement] (EK-A0519-UD.D01)
* [https://manx-docs.org/collections/mds-199909/cd1/vax/424aats1.pdf MicroVAX 3100 and VAXserver 3100 Options Installation Guide] (EK-424AA-TS-001)
* [https://www.filibeto.org/dec/mds/mds-1999-09/cd1/vax/424aats1.pdf MicroVAX 3100 and VAXserver 3100 Options Installation Guide] (EK-424AA-TS-001)
* [https://manx-docs.org/collections/antonio/dec/a0717opc.pdf MicroVAX 3100 Model 85/95/96 Operator Information] (EK–A0717–OP.C01)
* [https://vt100.net/mirror/antonio/a0717opc.pdf MicroVAX 3100 Model 85/95/96 Operator Information] (EK–A0717–OP.C01)
* [https://lastin.dti.supsi.ch/VET/sys/VAX/MicroVAX-3100-80/EK-AO525-TD-001.pdf MicroVAX 3100 Model 40 and Model 80 Customer Technical Information] (EK-A0525-TD.001)
* [https://lastin.dti.supsi.ch/VET/sys/VAX/MicroVAX-3100-80/EK-AO525-TD-001.pdf MicroVAX 3100 Model 40 and Model 80 Customer Technical Information] (EK-A0525-TD.001)
* [http://www.bitsavers.org/pdf/dec/vax/3100/EK-A0718-TI_MicroVAX_3100_85_95_Customer_Technical_Information_Jun94.pdf MicroVAX 3100 Model 85/95 Customer Technical Information] (EK-A0718-TI.B01)
* [http://www.bitsavers.org/pdf/dec/vax/3100/EK-A0718-TI_MicroVAX_3100_85_95_Customer_Technical_Information_Jun94.pdf MicroVAX 3100 Model 85/95 Customer Technical Information] (EK-A0718-TI.B01)
* [https://www.vaxhaven.com/images/7/70/EK-A0718-TI.C01.pdf MicroVAX 3100 Model 85/95/96 Customer Technical Information] (EK–A0718–TI.C01)
* [https://www.vaxhaven.com/images/7/70/EK-A0718-TI.C01.pdf MicroVAX 3100 Model 85/95/96 Customer Technical Information] (EK–A0718–TI.C01)
* [https://manx-docs.org/collections/antonio/dec/MDS-2000-01/cd1/VAX/M3148SIA.PDF MicroVAX 3100 Models 30/40/80 Supplement] (EK–M3148–SI.A0)
* [https://www.filibeto.org/dec/mds/mds-2000-01/cd1/VAX/M3148SIA.PDF MicroVAX 3100 Models 30/40/80 Supplement] (EK–M3148–SI.A0)
* [https://www.vaxhaven.com/images/b/bc/EK-M3185-UP-A01.pdf MicroVAX 3100 Model 40/80 to Model 85 CPU Upgrade Guide] (EK–M3185–UP. A01)
* [https://www.vaxhaven.com/images/b/bc/EK-M3185-UP-A01.pdf MicroVAX 3100 Model 40/80 to Model 85 CPU Upgrade Guide] (EK–M3185–UP. A01)
* [https://manx-docs.org/collections/antonio/dec/MDS-2000-01/cd1/VAX/A0612UP1.PDF MicroVAX 3100 Model 40 to Model 90 Upgrade Guide] (EK-A0612-UP.001)
* [https://www.filibeto.org/dec/mds/mds-2000-01/cd1/VAX/A0612UP1.PDF MicroVAX 3100 Model 40 to Model 90 Upgrade Guide] (EK-A0612-UP.001)
* [https://www.bbcusa.com/pdf/microvax-vaxstation/microvax-3100-overview.pdf MicroVAX 3100] - covers the Models 88 and 98, in the mini-tower packaging
* [https://www.bbcusa.com/pdf/microvax-vaxstation/microvax-3100-overview.pdf MicroVAX 3100] - covers the Models 88 and 98, in the mini-tower packaging
* [http://www.bitsavers.org/pdf/dec/brochures/DEC-MicroVAX-3100+VAX-4000.pdf MicroVAX 3100 and VAX 4000 Desktop Servers] - marketing brochure
* [http://www.bitsavers.org/pdf/dec/brochures/DEC-MicroVAX-3100+VAX-4000.pdf MicroVAX 3100 and VAX 4000 Desktop Servers] - marketing brochure

Latest revision as of 08:42, 13 October 2026

A MicroVAX 3100-80

The MicroVAX 3100 series was a line of entry-level desktop VAX minicomputer systems, all using a microprocessor VAX on a motherboard. (Several different VAX microprocessor implementations were used, over the life of the series.) Although they all had some I/O peripheral upgrades available, the list is limited; the 3100 was not built around a standard bus.

The CPU used was the KA41 CPU, KA45 CPU, KA47 CPU, KA50 CPU, KA51 CPU, KA55 CPU, KA56 CPU or KA59 CPU, depending on the model. Additional main memory was carried on daughter-boards in initial models; later SIMMs were used.

All models of the series supported SCSI for mass storage, as well as Ethernet and several asynchronous serial lines. Additional main memory, asynchronous serial lines, and synchronous serial lines, were available as options.

A desktop mounting box was used across most of the 3100 line; the Models 88 and 98 used mini-tower packaging. All models could run VMS and the older ones (presumably up to and including model 40) ULTRIX-32, too.

The models in the series were:

The Model 10 and Model 20 were very similar; the latter had a slightly larger mounting box.

The 3100's shared their motherboard and mounting box with the VAXserver 3100 series and VAXstation 3100 series.

Further reading

External links