Difference between revisions of "VAXserver 3500/3600"

From Computer History Wiki
Jump to: navigation, search
(Documentation error: Leave the details; having it in the Documentation Errors category without saying what is wrong would be annoying!)
m (Adopt formal group name syntax)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
The '''VAXserver 3500''' and '''VAXserver 3600''' are variants of the multi-user [[MicroVAX 3500/3600]]. The VAXserver 3500 and 3600 are very similar. The difference between the 3500 and 3600 is the placement of the systems: the 3500 uses the [[BA213]] enclosure, whereas the 3600 uses the bare BA213 chassis housed in the [[H9644 cabinet]] with a similar, but modified door. Both models have the same a 12-slot [[backplane]].
+
The '''VAXserver 3500''' and '''VAXserver 3600''' are [[VAXserver]] variants of the multi-user [[MicroVAX 3500/3600]]. The VAXserver 3500 and 3600 are very similar; the difference between the 3500 and 3600 is the mounting of the systems. The 3500 uses the [[BA213]] enclosure, whereas the 3600 uses the bare BA213 chassis housed in the [[H9644 cabinet]] with a similar, but modified door. Both models have the same 12-slot [[backplane]].
  
 
Both used the [[KA650 CPU]]. The [[QBUS]], which both are built around, was used only for [[input/output|I/O]]; [[main memory]] used the [[KA650 Main Memory System]], using a special [[bus]] carried on [[over the back]] connectors as well as the [[CD interconnect]] of the QBUS backplane. (The [[address space]] of the [[QBUS]] was limited to 4MB, and the data section is only 16 bits wide.)
 
Both used the [[KA650 CPU]]. The [[QBUS]], which both are built around, was used only for [[input/output|I/O]]; [[main memory]] used the [[KA650 Main Memory System]], using a special [[bus]] carried on [[over the back]] connectors as well as the [[CD interconnect]] of the QBUS backplane. (The [[address space]] of the [[QBUS]] was limited to 4MB, and the data section is only 16 bits wide.)
Line 5: Line 5:
 
==Documentation error==
 
==Documentation error==
  
The [http://vtda.org/docs/computing/DEC/VMS/EK-O35AB-IS-002_MicroVAX_3600_VAXserver_3600_3602_Technical_Information_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Technical Information] manual incorrectly says that both the 3500 and 3600 used the BA213 enclosure. (The [http://vtda.org/docs/computing/DEC/VMS/EK-O33AB-OM-002_MicroVAX_3600_VAXserver_3600_3602_Operation_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Operation] manual correctly states that the 3600 in the H9644 cabinet.)
+
The [http://vtda.org/docs/computing/DEC/VMS/EK-O35AB-IS-002_MicroVAX_3600_VAXserver_3600_3602_Technical_Information_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Technical Information] manual misleadingly (but ''technically'' correctly) says that both the 3500 and 3600 used the BA213 enclosure. (The [http://vtda.org/docs/computing/DEC/VMS/EK-O33AB-OM-002_MicroVAX_3600_VAXserver_3600_3602_Operation_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Operation] manual correctly states that the 3600 is in the H9644 cabinet.)
  
 
{{semi-stub}}
 
{{semi-stub}}
Line 18: Line 18:
 
{{Nav VAX}}
 
{{Nav VAX}}
  
[[Category: DEC VAX systems]]
+
[[Category: VAXservers]]
 +
[[Category: QBUS VAX Systems]]
 
[[Category: DEC Documentation Errors]]
 
[[Category: DEC Documentation Errors]]

Latest revision as of 14:57, 23 May 2024

The VAXserver 3500 and VAXserver 3600 are VAXserver variants of the multi-user MicroVAX 3500/3600. The VAXserver 3500 and 3600 are very similar; the difference between the 3500 and 3600 is the mounting of the systems. The 3500 uses the BA213 enclosure, whereas the 3600 uses the bare BA213 chassis housed in the H9644 cabinet with a similar, but modified door. Both models have the same 12-slot backplane.

Both used the KA650 CPU. The QBUS, which both are built around, was used only for I/O; main memory used the KA650 Main Memory System, using a special bus carried on over the back connectors as well as the CD interconnect of the QBUS backplane. (The address space of the QBUS was limited to 4MB, and the data section is only 16 bits wide.)

Documentation error

The MicroVAX 3600 VAXserver 3600/3602 Technical Information manual misleadingly (but technically correctly) says that both the 3500 and 3600 used the BA213 enclosure. (The MicroVAX 3600 VAXserver 3600/3602 Operation manual correctly states that the 3600 is in the H9644 cabinet.)

External links