MicroVAX 3500/3600: Difference between revisions
mNo edit summary |
m Move to formal group |
||
| (15 intermediate revisions by 5 users not shown) | |||
| Line 1: | Line 1: | ||
{{ | {{InfoboxVAX-Data | ||
| name = MicroVAX 3500/3600 | | name = MicroVAX 3500/3600 | ||
| | | image = MicrVAX 3600.jpg | ||
| | | imgwidth = 200px | ||
| | | caption = A MicroVAX 3600 | ||
| | | Announcement = 9 September 1987 | ||
| | | Codename = Mayfair | ||
| | | OS-support-VMS = V4.7A or later | ||
| | | OS-support-ULTRIX = ULTRIX V2.2 | ||
| | | CPU-name-VMS = KA650 | ||
| CPU-name-console = KA650-A | |||
| CPU-module = [[KA650 CPU|KA650]] | |||
| Module = M7620 | |||
| Num-proc = 1 | |||
| VMS-CPU = 10 | |||
| VMS-XCPU = 1 | |||
| SID = 0A000005 | |||
| XSID = 01530101 | |||
| CPU-chip = 78034 (CVAX) [[#ref_2|[2]]] | |||
| FPU-chip = 78132 | |||
| CPU-technology = CMOS | |||
| CPU-cycle = 90ns [[#ref_2|[2]]] | |||
| Instruction-buffer = 12 bytes [[#ref_2|[2]]] | |||
| Translation-buffer = 28 entries [[#ref_2|[2]]] | |||
| Cache = 1KB (90ns) [[#ref_2|[2]]] | |||
| Backup-cache = 64KB (180ns) [[#ref_2|[2]]] | |||
| Compatibility-mode = No | |||
| Console-processor = CPU | |||
| Console-device = None | |||
| Firmware-version = V5.3 | |||
| Minimum-memory = 2MB | |||
| Maximum-memory = 64MB | |||
| BUS-Qbus = 1 @ 3.3MB/s | |||
| LAN-support = optional | |||
| VUPs = 2.7 [[#ref_4|[4]]] | |||
}} | }} | ||
[[ | The '''MicroVAX 3500''' and '''MicroVAX 3600''' are variants of the [[VAXserver 3500/3600]]. The MicroVAX 3500 and 3600 are very similar. The difference between the 3500 and 3600 is the placement of the systems: the 3500 uses the [[BA213]] enclosure, whereas the 3600 uses the bare BA213 chassis housed in the [[H9644 cabinet]] with a similar, but modified door. Both models have the same a 12-slot [[backplane]]. | ||
They used the [[KA650 CPU]]; [[main memory]] used the [[KA650 Main Memory System]], using a special bus carried on [[over the back]] connectors as well as the [[CD interconnect]] of the [[QBUS]] [[backplane]]. The QBUS was used only for [[input/output|I/O]]. | |||
==Documentation error== | |||
The [http://vtda.org/docs/computing/DEC/VMS/EK-O35AB-IS-002_MicroVAX_3600_VAXserver_3600_3602_Technical_Information_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Technical Information] manual says that both the 3500 and 3600 used the BA213 enclosure. (The [http://vtda.org/docs/computing/DEC/VMS/EK-O33AB-OM-002_MicroVAX_3600_VAXserver_3600_3602_Operation_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Operation] manual says that the 3600 is in the H9644 cabinet.) | |||
{{semi-stub}} | |||
== References == | |||
<div id="ref_1">[1] Special Sales Update. Sep 1987. </div> | |||
<div id="ref_2">[2] "CVAX-based Systems", [[Digital Technical Journal]], Vol 1 No 7, August 1988. </div> | |||
<div id="ref_3">[3] VAX Systems Hardware Handbook -- VAXBI Systems. EB-31692-46</div> | |||
<div id="ref_4">[4] [http://www.vaxhaven.com/images/c/c6/EK-VAXCT-CG-006.pdf VAXcluster Systems - Guidelines for VAXcluster System Configurations] (EK-VAXCT-CG-006)</div> | |||
==External links== | |||
* [http://www.ext.zx.net.nz/computers/dec/microvax3500/docs MicroVAX 3500 documentation] | |||
** [http://www.ext.zx.net.nz/computers/dec/microvax3500/docs/EK-O28AB-OM-002.pdf MicroVAX 3500 VAXserver 3500 Operation] (EK-O28AB-OM-002) | |||
* [http://www.vaxhaven.com/images/1/1e/EK-O30AB-IS-002.pdf MicroVAX 3500 VAXserver 3500 Technical Information] (EK-O30AB-IS-002) | |||
* [http://vtda.org/docs/computing/DEC/VMS/EK-O33AB-OM-002_MicroVAX_3600_VAXserver_3600_3602_Operation_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Operation] (EK-O33AB-OM-002) | |||
* [http://vtda.org/docs/computing/DEC/VMS/EK-O35AB-IS-002_MicroVAX_3600_VAXserver_3600_3602_Technical_Information_Jul1988.pdf MicroVAX 3600 VAXserver 3600/3602 Technical Information] (EK-O35AB-IS-002) | |||
* [http://www.ext.zx.net.nz/computers/dec/microvax3500/ MicroVAX 3500] | |||
{{Nav VAX}} | {{Nav VAX}} | ||
[[Category: MicroVAX Systems]] | |||
[[Category: QBUS VAX Systems]] | |||
[[Category: DEC Documentation Errors]] | |||
Latest revision as of 14:19, 23 May 2024
| MicroVAX 3500/3600 | |
A MicroVAX 3600 | |
| Summary | |
|---|---|
| Announcement date: | 9 September 1987 |
| Codename: | Mayfair |
| OS support (VMS): | V4.7A or later |
| OS support (ULTRIX): | ULTRIX V2.2 |
| CPU Details | |
| CPU name (VMS): | KA650 |
| CPU name (console): | KA650-A |
| CPU module: | KA650 |
| Module: | M7620 |
| Number of processors: | 1 |
| VMS DCL CPU: | 10 |
| VMS DCL XCPU: | 1 |
| SID: | 0A000005 |
| XSID: | 01530101 |
| CPU chip: | 78034 (CVAX) [2] |
| FPU chip: | 78132 |
| CPU technology: | CMOS |
| CPU cycle time: | 90ns [2] |
| Instruction-buffer: | 12 bytes [2] |
| Translation-buffer: | 28 entries [2] |
| Cache: | 1KB (90ns) [2] |
| Backup cache: | 64KB (180ns) [2] |
| Compatibility mode: | No |
| Console processor: | CPU |
| Console device: | None |
| Firmware version: | V5.3 |
| Memory | |
| Minimum memory: | 2MB |
| Maximum memory: | 64MB |
| I/O | |
| Q-bus: | 1 @ 3.3MB/s |
| LAN support: | optional |
| Performance | |
| VUPs: | 2.7 [4] |
The MicroVAX 3500 and MicroVAX 3600 are variants of the VAXserver 3500/3600. The MicroVAX 3500 and 3600 are very similar. The difference between the 3500 and 3600 is the placement of the systems: the 3500 uses the BA213 enclosure, whereas the 3600 uses the bare BA213 chassis housed in the H9644 cabinet with a similar, but modified door. Both models have the same a 12-slot backplane.
They used the KA650 CPU; main memory used the KA650 Main Memory System, using a special bus carried on over the back connectors as well as the CD interconnect of the QBUS backplane. The QBUS was used only for I/O.
Documentation error
The MicroVAX 3600 VAXserver 3600/3602 Technical Information manual says that both the 3500 and 3600 used the BA213 enclosure. (The MicroVAX 3600 VAXserver 3600/3602 Operation manual says that the 3600 is in the H9644 cabinet.)
References
External links
- MicroVAX 3500 documentation
- MicroVAX 3500 VAXserver 3500 Operation (EK-O28AB-OM-002)
- MicroVAX 3500 VAXserver 3500 Technical Information (EK-O30AB-IS-002)
- MicroVAX 3600 VAXserver 3600/3602 Operation (EK-O33AB-OM-002)
- MicroVAX 3600 VAXserver 3600/3602 Technical Information (EK-O35AB-IS-002)
- MicroVAX 3500
| v • d • e VAX Computers and Operating Systems |
|---|
| VAX-11/7xx (including VAX 86x0) - VAX-11/780 • VAX-11/785 • VAX-11/750 • VAX-11/730 • VAX-11/725 • VAX 8600 • VAX 8650
VAX 8000 series (excluding VAX 86x0, above) - VAX 82xx/83xx series • VAX 85xx/87xx/88xx series MicroVAXen (many types also come in VAXserver and VAXstation models) - MicroVAX I • MicroVAX II VAXstation Series - VAXstation I • VAXstation II Late Model VAXen - VAX 4000 series • VAX 6000 series • VAX 7000 series • VAX 9000 series • VAX 10000 series |
| Special Purpose VAXen - VAXft series • rtVAX series • Infoserver series
Clones - CM 1700 • TPA-11/580 |