Modified UNIBUS Device
Modified UNIBUS Device or MUD was DEC's name for an I/O board slot in the backplanes of UNIBUS PDP-11s. It was a hex slot, and could hold any kind of device.
It differed from the older SPC slot in that it was a hex-height slot, and used the pins (in the A-B connectors) to carry UNIBUS signals - mostly pin-compatible with the original dual UNIBUS slot, but there were a few important differences.
The most important was that since the standard UNIBUS dual connector only contains one pin per bus grant line (suitable only for an 'in' or 'out' UNIBUS connector), not separate 'grant in' and 'grant out' pins (as on the QBUS), a full-function UNIBUS slot is not possible with only two connectors. The MUD connectors therefore do not contain grants; those pins were recycled for other functions.
Some re-assigned pins contain a number of lines for communication between a parity controller, and parity-capable main memory boards plugged into that backplane; others carry additional voltages (primarily for core memory).
Technically, a MUD slot only describes the A-B connectors; most backplanes also provided SPC functionality in the C-F connectors (needed for signals for interrupts or DMA, for devices which did those), with most UNIBUS signals present in both; the combination is sometimes called a 'MUD/SPC' slot.
The DD11-C (4-slot) and DD11-D (9-slot) and later backplanes generally provided MUD slots, not the earlier SPC slots; however, generally the slots in these later backplanes are MUD/SPC - other than the entrance and exit slots, which have normal two-slot UNIBUS in/out in A-B, and SPC in C-F.
Grants
MUD/SPC slots were wired to bring all 5 UNIBUS grant lines through the device; this was performed in rows C (for NPG) and D (for BGx), not the 'pseudo-UNIBUS' rows A/B.
A board plugged into a MUD/SPC slot generally had a header which routed the grant (and matching request) line for the desired priority level to the on-board interrupt circuity, and passed the other grant lines through.
The DMA (NPG) grant line generally had a jumper on the backplane, which had to be removed if a DMA device was plugged into the slot.
Un-occupied slots needed to have a grant continuity card installed.
Added signals
The added lines for communication between a parity controller and parity-capable memory boards were Parity Detect (used to let memory boards know that a parity controller is present); Internal SSYN (used by memory boards to let the parity controller know that their data is ready); and Parity P0 and Parity P1 (parity data).
The additional voltages were + and -15V, -5V, and +20V. Note that in some machines (the PDP-11/44 and PDP-11/24) the +15V/-15 pins actually contain +12V/-12V, for use by the MS11-M MOS memory card, which needs those voltages. +15V/-15V are available in the SPC portion of some such slots.
Pinout
The pins which were added (changed) to create MUD are:
- AB2 - Test Point
- AN1 - Parity P1
- AP1 - Parity P0
- AR1 - -15/12 Battery
- AS1 - -15/12 Battery
- AU1 - +20V (core)
- AV1 - +20V (core)
- AV2 - +20V (core)
- BA1 - Reserved
- BB1 - Reserved
- BB2 - Test Point
- BD1 - +5V Battery
- BE1 - Internal SSYN
- BE2 - Parity Detect
- BV2 - -5V (core)
Removed signals
Since grants could not be supported in the number of pins available in a dual connector, all grant pins were removed, along with some ground pins.
Pins
The pins which changed function from normal UNIBUS to MUD are listed below.
- AB2 - Ground
- AN1 - Ground
- AP1 - Ground
- AR1 - Ground
- AS1 - Ground
- AU1 - NPG
- AV1 - BG7
- AV2 - Ground
- BA1 - BG6
- BB1 - BG5
- BB2 - Ground
- BD1 - Ground
- BE1 - Ground
- BE2 - BG4
- BV2 - Ground
See also
External links
- DD11-A Engineering Drawings
- DD11-B Engineering Drawings
- DD11-C Engineering Drawings - DD11-CK and DD11-CF wiring harness requirements can be found on pages 5 & 7
- DD11-D Engineering Drawings - DD11-DK and DD11-DF wiring harness requirements can be found on pages 6 & 7
- DD11-P Engineering Drawings
v • d • e PDP-11 Computers and Peripherals |
---|
UNIBUS PDP-11s - PDP-11/20 • PDP-11/15 • PDP-11/35 • PDP-11/40 • PDP-11/45 • PDP-11/50 • PDP-11/55 • PDP-11/70 PDP-11/05 • PDP-11/10 • PDP-11/04 • PDP-11/34 • PDP-11/60 • PDP-11/44 • PDP-11/24 • PDP-11/84 • PDP-11/94 QBUS PDP-11s - PDP-11/03 • PDP-11/23 • PDP-11/23+ • MicroPDP-11/73 • MicroPDP-11/53 • MicroPDP-11/83 • MicroPDP-11/93 QBUS CPUs: LSI-11 • LSI-11/2 • KDF11-A • KDF11-B • KDJ11-A • KDJ11-B • KDJ11-D • KDJ11-E Buses: UNIBUS • UNIBUS map • SPC • MUD • EUB • QBUS • CD interconnect • PMI Also: PDP-11 architecture • PDP-11 Extended Instruction Set • FP11 floating point • PDP-11 Memory Management |
UNIBUS CPUs: KA11 • KC11 • KB11-A • KB11-B • KB11-C • KB11-D • KD11-A • KD11-B • KD11-D • KD11-E • KD11-EA • KD11-K • KD11-Z • KDF11-U
Co-processors: FP11-A • FP11-B • FP11-C • FP11-E • FP11-F • KE44-A • FPF11 Chips: LSI-11 • KEV11-A • KEV11-B • KEV11-C • F-11 • KEF11-A • KTF11-A • T-11 • J-11 • FPJ11 CPU options: KE11-E • KE11-F • KJ11-A • KT11-C • KT11-D • KK11-A • KK11-B • KT24 • KTJ11-B Rare CPU options: KS11 Memory Protection and Relocation option • KT11-B Paging Option • KUV11 Writeable Control Store Front panels: KY11-A • KY11-D • KY11-J • KY11-LA • KY11-LB • KY11-P More on buses: UNIBUS and QBUS termination • Bus Arbitration on the Unibus and QBUS • CTI BUS PDT-11s - PDT-11/110 • PDT-11/130 • PDT-11/150 CTI PDP-11s - PRO-325 • PRO-350 • PRO-380 Other: FIS floating point • PDP-11 Commercial Instruction Set • PDP-11 stacks • PDP-11 family differences |