Difference between revisions of "DH11 asynchronous serial line interface"
(Final? tweaks) |
(Copy-edit for clarity) |
||
Line 8: | Line 8: | ||
* parity (odd, even, none) | * parity (odd, even, none) | ||
− | could be set dynamically (unlike, for example. the [[DJ11]], which set parameters for groups of lines using [[jumper]]s). Output used [[DMA]] (with each line having its own buffer pointer and count); on input a 64-character [[FIFO]] buffer made over-runs unlikely. | + | could be set dynamically (unlike, for example. the [[DJ11]], which set parameters for groups of lines using [[jumper]]s). Output used [[DMA]] (with each line having its own buffer pointer and count); on input a 64-character [[FIFO]] buffer made over-runs unlikely. A 'break' condition on the line (i.e. continuous assertion) could also be generated and detected. |
In the initial version, modular 'line conditioning' units allowed support of either [[20mA current loop serial line interface|20mA]] or [[EIA RS-232 serial line interface|EIA RS-232]] serial lines. | In the initial version, modular 'line conditioning' units allowed support of either [[20mA current loop serial line interface|20mA]] or [[EIA RS-232 serial line interface|EIA RS-232]] serial lines. | ||
− | + | For modem control, a single DM11-BB per DH11, mounted in the main DH11 backplane along with the rest of the DH11 cards, was required. (The DM11-BB is logically a separate device, albeit one housed in, and only used with, the DH11.) | |
==Initial implementation== | ==Initial implementation== | ||
Line 18: | Line 18: | ||
The original implementation took an entire double [[system unit]], containing multiple cards (see list below). | The original implementation took an entire double [[system unit]], containing multiple cards (see list below). | ||
− | It came in 'earlier' and 'later' versions: in the 'early' versions the line conditioning units (to adapt from TTL to either EIA, 20mA, etc) were installed in a separate rack-mounted [[DEC card form factor|dual-height]] [[backplane]] (which required its own independent [[power supply]]); in the 'later' units line conditioning was performed by boards mounted in the main backplane, and a rack-mounted passive distribution panel provided connectors for individual lines. | + | It came in 'earlier' and 'later' versions: in the 'early' versions the line conditioning units (to adapt from TTL to either EIA, 20mA, etc) were installed in a separate rack-mounted [[DEC card form factor|dual-height]] [[backplane]] (which required its own independent [[power supply]]); in the 'later' units line conditioning was performed by boards mounted in the main DH11 backplane, and a rack-mounted passive distribution panel provided connectors for individual lines. |
− | For the 'early' versions, the available line conditioning units included the DM11-DA (20mA line conditioning) and the DM11-DA (EIA, no modem conrol). Each supported four lines; thus, line conditioning could be mixed in groups of four. | + | For the 'early' versions, the available line conditioning units included the DM11-DA (20mA line conditioning) and the DM11-DA (EIA, no modem conrol). Each supported four lines; thus, line conditioning could be mixed in groups of four. The 'early' version of the DM11-BB connected to four DM11-DC's. |
− | + | The 'later' versions of the DH11 only supported EIA-type line conditioning (with or without modem control); to add modem control, a different implementation of the DM11-BB was required (one which did the EIA level conversion internally). | |
− | |||
− | The 'later' versions only supported EIA-type line conditioning (with or without | ||
===Versions=== | ===Versions=== | ||
Line 30: | Line 28: | ||
The 'early' versions of the DH11 were: | The 'early' versions of the DH11 were: | ||
− | * DH11-AA - Basic unit (110VAC), requires DM11's in addition | + | * DH11-AA - Basic unit (110VAC), requires DM11-D's in addition |
* DH11-AB - Telegraph line version (see below) | * DH11-AB - Telegraph line version (see below) | ||
− | * DH11-AC - Basic unit (220VAC), requires DM11's in addition | + | * DH11-AC - Basic unit (220VAC), requires DM11-D's in addition |
− | The 'later' versions were: | + | The 'later' versions, which used an H317-B passive distribution panel, were: |
− | * DH11-AD - EIA level conversion, modem control | + | * DH11-AD - EIA level conversion, modem control |
− | * DH11-AE - EIA level conversion, no modem control | + | * DH11-AE - EIA level conversion, no modem control |
For the telegraph line option, the line conditioning backplane and its power supply were omitted, and up to two DH11's were connected to a DC08CS Telegraph Converter Panel. | For the telegraph line option, the line conditioning backplane and its power supply were omitted, and up to two DH11's were connected to a DC08CS Telegraph Converter Panel. | ||
Line 55: | Line 53: | ||
* M7821 (2) - Interrupt control (transmit and receive) | * M7821 (2) - Interrupt control (transmit and receive) | ||
− | The DM11-BB used: | + | The 'early' DM11-BB used: |
* M7246 - Control Scan | * M7246 - Control Scan | ||
Line 62: | Line 60: | ||
* M7821 - Interrupt control | * M7821 - Interrupt control | ||
− | + | The 'later' versions of the DH11 both included: | |
− | |||
− | The 'later' versions both included: | ||
* M5906 EIA conversion module | * M5906 EIA conversion module | ||
Line 70: | Line 66: | ||
which occupied a dual slot (used by an M7360 Priority Selector card and an M971 Cable Connector card, used to connect the DH11 to the line conditioning units, in the 'early' versions). | which occupied a dual slot (used by an M7360 Priority Selector card and an M971 Cable Connector card, used to connect the DH11 to the line conditioning units, in the 'early' versions). | ||
− | The -AD version, which included modem control, also used: | + | The -AD version, which included a 'later' DM11-BB for modem control, also used: |
* M7807 - Mux and Bus Control | * M7807 - Mux and Bus Control | ||
* M7808 - Mux and Modem Scan Control | * M7808 - Mux and Modem Scan Control | ||
− | These boards fitted into the slots occupied by the DM11-BB boards in the 'early' versions. | + | These boards fitted into the same slots occupied by the DM11-BB boards in the 'early' versions. |
Finally, an optional M794 maintenance card could be plugged into the slot normally used by the M971, for testing. | Finally, an optional M794 maintenance card could be plugged into the slot normally used by the M971, for testing. | ||
Line 93: | Line 89: | ||
The DM11-DC used only the M594. | The DM11-DC used only the M594. | ||
− | ==Later | + | ==Later implementations== |
− | The DH11 was later re-implemented as the [[DHU11]], which was programmatically identical, but fitted on a single [[DEC card form factor|hex-height]] card, which plugged into a [[ | + | The DH11 was later re-implemented as the [[DHU11]], which was mostly programmatically identical, but fitted on a single [[DEC card form factor|hex-height]] card, which plugged into a [[Small Peripheral Controller|SPC]] slot. |
For the [[QBUS]], the [[DHV11]] and [[DHQ11]] (again, programmatically identical) appeared; they only supported 8 lines (via two quad breakout panels) each, however. | For the [[QBUS]], the [[DHV11]] and [[DHQ11]] (again, programmatically identical) appeared; they only supported 8 lines (via two quad breakout panels) each, however. | ||
{{PDP-11}} | {{PDP-11}} |
Revision as of 13:59, 8 May 2017
The DH11 asynchronous serial line interface is a UNIBUS device which supports up to 16 asynchronous serial lines; as a UNIBUS device, it was usable on the PDP-11 and VAX computers. Although it first appeared very early on in the lifetime of the PDP-11, it was extremely powerful and flexible.
The parameters for each line:
- separate input and output baud rates (50 to 9600)
- character length (5-8 bits)
- stop bits (1, 1-1/2 and 2)
- parity (odd, even, none)
could be set dynamically (unlike, for example. the DJ11, which set parameters for groups of lines using jumpers). Output used DMA (with each line having its own buffer pointer and count); on input a 64-character FIFO buffer made over-runs unlikely. A 'break' condition on the line (i.e. continuous assertion) could also be generated and detected.
In the initial version, modular 'line conditioning' units allowed support of either 20mA or EIA RS-232 serial lines.
For modem control, a single DM11-BB per DH11, mounted in the main DH11 backplane along with the rest of the DH11 cards, was required. (The DM11-BB is logically a separate device, albeit one housed in, and only used with, the DH11.)
Contents
Initial implementation
The original implementation took an entire double system unit, containing multiple cards (see list below).
It came in 'earlier' and 'later' versions: in the 'early' versions the line conditioning units (to adapt from TTL to either EIA, 20mA, etc) were installed in a separate rack-mounted dual-height backplane (which required its own independent power supply); in the 'later' units line conditioning was performed by boards mounted in the main DH11 backplane, and a rack-mounted passive distribution panel provided connectors for individual lines.
For the 'early' versions, the available line conditioning units included the DM11-DA (20mA line conditioning) and the DM11-DA (EIA, no modem conrol). Each supported four lines; thus, line conditioning could be mixed in groups of four. The 'early' version of the DM11-BB connected to four DM11-DC's.
The 'later' versions of the DH11 only supported EIA-type line conditioning (with or without modem control); to add modem control, a different implementation of the DM11-BB was required (one which did the EIA level conversion internally).
Versions
The 'early' versions of the DH11 were:
- DH11-AA - Basic unit (110VAC), requires DM11-D's in addition
- DH11-AB - Telegraph line version (see below)
- DH11-AC - Basic unit (220VAC), requires DM11-D's in addition
The 'later' versions, which used an H317-B passive distribution panel, were:
- DH11-AD - EIA level conversion, modem control
- DH11-AE - EIA level conversion, no modem control
For the telegraph line option, the line conditioning backplane and its power supply were omitted, and up to two DH11's were connected to a DC08CS Telegraph Converter Panel.
Main Boards
The 'basic' DH11 included the following boards:
- M7277 - Transmit scanner and NPR
- M7278 - Registers and byte count
- M7279 - FIFO buffer
- M7280 (2) - Multiple UARTs
- M7288 - Line parameters control
- M7289 - Receiver scanner
- M4540 - Crystal clock
- M796 - Unibus master control
- M7821 (2) - Interrupt control (transmit and receive)
The 'early' DM11-BB used:
- M7246 - Control Scan
- M7247 (2) - Control Mux
- M105 - Address selector
- M7821 - Interrupt control
The 'later' versions of the DH11 both included:
- M5906 EIA conversion module
which occupied a dual slot (used by an M7360 Priority Selector card and an M971 Cable Connector card, used to connect the DH11 to the line conditioning units, in the 'early' versions).
The -AD version, which included a 'later' DM11-BB for modem control, also used:
- M7807 - Mux and Bus Control
- M7808 - Mux and Modem Scan Control
These boards fitted into the same slots occupied by the DM11-BB boards in the 'early' versions.
Finally, an optional M794 maintenance card could be plugged into the slot normally used by the M971, for testing.
Line conditioning boards
The line conditioning units, mounted in the separate backplane used in the 'early' versions, included, in the DM11-DA:
- M596 - TTL to 20mA Level Converter (4 channels each)
- M973 - Mate-N-Lok header
and in the DM11-DB:
- M594 - TTL to EIA Level Converter (4 channels each)
- W404 - DTR Jumper card
The DM11-DC used only the M594.
Later implementations
The DH11 was later re-implemented as the DHU11, which was mostly programmatically identical, but fitted on a single hex-height card, which plugged into a SPC slot.
For the QBUS, the DHV11 and DHQ11 (again, programmatically identical) appeared; they only supported 8 lines (via two quad breakout panels) each, however.
v • d • e PDP-11 Computers and Peripherals |
---|
UNIBUS PDP-11s - PDP-11/20 • PDP-11/15 • PDP-11/35 • PDP-11/40 • PDP-11/45 • PDP-11/50 • PDP-11/55 • PDP-11/70 PDP-11/05 • PDP-11/10 • PDP-11/04 • PDP-11/34 • PDP-11/60 • PDP-11/44 • PDP-11/24 • PDP-11/84 • PDP-11/94 QBUS PDP-11s - PDP-11/03 • PDP-11/23 • PDP-11/23+ • MicroPDP-11/73 • MicroPDP-11/53 • MicroPDP-11/83 • MicroPDP-11/93 QBUS CPUs: LSI-11 • LSI-11/2 • KDF11-A • KDF11-B • KDJ11-A • KDJ11-B • KDJ11-D • KDJ11-E Buses: UNIBUS • UNIBUS map • SPC • MUD • EUB • QBUS • CD interconnect • PMI Also: PDP-11 architecture • PDP-11 Extended Instruction Set • FP11 floating point • PDP-11 Memory Management |
UNIBUS CPUs: KA11 • KC11 • KB11-A • KB11-B • KB11-C • KB11-D • KD11-A • KD11-B • KD11-D • KD11-E • KD11-EA • KD11-K • KD11-Z • KDF11-U
Co-processors: FP11-A • FP11-B • FP11-C • FP11-E • FP11-F • KE44-A • FPF11 Chips: LSI-11 • KEV11-A • KEV11-B • KEV11-C • F-11 • KEF11-A • KTF11-A • T-11 • J-11 • FPJ11 CPU options: KE11-E • KE11-F • KJ11-A • KT11-C • KT11-D • KK11-A • KK11-B • KT24 • KTJ11-B Rare CPU options: KS11 Memory Protection and Relocation option • KT11-B Paging Option • KUV11 Writeable Control Store Front panels: KY11-A • KY11-D • KY11-J • KY11-LA • KY11-LB • KY11-P More on buses: UNIBUS and QBUS termination • Bus Arbitration on the Unibus and QBUS • CTI BUS PDT-11s - PDT-11/110 • PDT-11/130 • PDT-11/150 CTI PDP-11s - PRO-325 • PRO-350 • PRO-380 Other: FIS floating point • PDP-11 Commercial Instruction Set • PDP-11 stacks • PDP-11 family differences |