It came in 'earlier' and 'later' versions: in the 'early' versions the line conditioning units (to adapt from TTL to either EIA, 20mA, etc) were installed in a separate rack-mounted [[DEC card form factor|dual-height]] [[backplane]] (which required its own independent [[power supply]]); in the 'later' units line conditioning was performed by boards mounted in the main backplane, and a rack-mounted passive distribution panel provided connectors for individual lines. | It came in 'earlier' and 'later' versions: in the 'early' versions the line conditioning units (to adapt from TTL to either EIA, 20mA, etc) were installed in a separate rack-mounted [[DEC card form factor|dual-height]] [[backplane]] (which required its own independent [[power supply]]); in the 'later' units line conditioning was performed by boards mounted in the main backplane, and a rack-mounted passive distribution panel provided connectors for individual lines. | ||
− | For the 'early' versions, the available line conditioning units included the DM11-DA (20mA line conditioning) and the DM11-DA (EIA, no modem conrol). Each supported four lines; thus, line conditioning could be mixed in groups of four. For modem control, a single DM11-BB per DH11 was required, which in turn connected to four DM11-DC's. | + | For the 'early' versions, the available line conditioning units included the DM11-DA (20mA line conditioning) and the DM11-DA (EIA, no modem conrol). Each supported four lines; thus, line conditioning could be mixed in groups of four. |
+ | |||
+ | For modem control, a single DM11-BB per DH11, mounted in the main DH11 backplane along with the rest of the DH11 cards, was required, which in turn connected to four DM11-DC's. | ||
The 'later' versions only supported EIA-type line conditioning (with or without model control). | The 'later' versions only supported EIA-type line conditioning (with or without model control). | ||
Line 60: | Line 62: | ||
* M7807 - Mux and Bus Control | * M7807 - Mux and Bus Control | ||
− | * M7808 - Mux and Modem Scan Control | + | * M7808 - Mux and Modem Scan Control |
+ | |||
+ | The line conditioning units used in the 'early' versions included, in the DM11-DA: | ||
+ | |||
+ | * M596 - TTL to 20mA Level Converter (4 channels each) | ||
+ | * M973 - Mate-N-Lok header | ||
+ | |||
+ | and in the DM11-DB: | ||
+ | |||
+ | * M594 - TTL to EIA Level Converter (4 channels each) | ||
+ | * W404 - DTR Jumper card | ||
+ | |||
+ | The DM11-DC used only the M594. | ||
==Later versions== | ==Later versions== |
Revision as of 18:38, 7 May 2017
The DH11 asynchronous serial line interface is a UNIBUS device which supports up to 16 asynchronous serial lines; as a UNIBUS device, it was usable on the PDP-11 and VAX computers. Although it first appeared very early on in the lifetime of the PDP-11, it was extremely powerful and flexible.
The parameters for each line:
- separate input and output baud rates (50 to 9600)
- character length (5-8 bits)
- stop bits (1, 1-1/2 and 2)
- parity (odd, even, none)
could be set dynamically (unlike, for example. the DJ11, which set parameters for groups of lines using jumpers). Output used DMA (with each line having its own buffer pointer and count); on input a 64-character FIFO buffer made over-runs unlikely.
In the initial version, modular 'line conditioning' units allowed support of either 20mA or EIA RS-232 serial lines.
A 'break' condition on the line (i.e. continuous assertion) could also be generated and detected.
Initial implementation
The original implementation took an entire double system unit, containing multiple cards (see list below).
It came in 'earlier' and 'later' versions: in the 'early' versions the line conditioning units (to adapt from TTL to either EIA, 20mA, etc) were installed in a separate rack-mounted dual-height backplane (which required its own independent power supply); in the 'later' units line conditioning was performed by boards mounted in the main backplane, and a rack-mounted passive distribution panel provided connectors for individual lines.
For the 'early' versions, the available line conditioning units included the DM11-DA (20mA line conditioning) and the DM11-DA (EIA, no modem conrol). Each supported four lines; thus, line conditioning could be mixed in groups of four.
For modem control, a single DM11-BB per DH11, mounted in the main DH11 backplane along with the rest of the DH11 cards, was required, which in turn connected to four DM11-DC's.
The 'later' versions only supported EIA-type line conditioning (with or without model control).
Versions
The 'early' versions of the DH11 were:
- DH11-AA - Basic unit (110VAC), requires DM11's in addition
- DH11-AB - Telegraph line version (see below)
- DH11-AC - Basic unit (220VAC), requires DM11's in addition
The 'later' versions were:
- DH11-AD - EIA level conversion, modem control, H317-B passive distribution panel
- DH11-AE - EIA level conversion, no modem control, H317-B passive distribution panel
For the telegraph line option, the line conditioning backplane and its power supply were omitted, and up to two DH11's were connected to a DC08CS Telegraph Converter Panel.
Boards
The 'basic' DH11 included the following boards:
- M7277 - Transmit scanner and NPR
- M7278 - Registers and byte count
- M7279 - FIFO buffer
- M7280 - Multiple UARTs
- M7288 - Line parameters control
- M7289 - Receiver scanner
- M4540 - Crystal clock
- M796 - Unibus master control
- M7821 (2) - Interrupt control (transmit and receive)
The 'later' versions both included:
- M5906 EIA conversion module
The -AD version, which included modem control, also used:
- M7807 - Mux and Bus Control
- M7808 - Mux and Modem Scan Control
The line conditioning units used in the 'early' versions included, in the DM11-DA:
- M596 - TTL to 20mA Level Converter (4 channels each)
- M973 - Mate-N-Lok header
and in the DM11-DB:
- M594 - TTL to EIA Level Converter (4 channels each)
- W404 - DTR Jumper card
The DM11-DC used only the M594.
Later versions
The DH11 was later re-implemented as the DHU11, which was programmatically identical, but fitted on a single hex-height card, which plugged into a MUD slot.
For the QBUS, the DHV11 and DHQ11 (again, programmatically identical) appeared; they only supported 8 lines (via two quad breakout panels) each, however.
v • d • e PDP-11 Computers and Peripherals |
---|
UNIBUS PDP-11s - PDP-11/20 • PDP-11/15 • PDP-11/35 • PDP-11/40 • PDP-11/45 • PDP-11/50 • PDP-11/55 • PDP-11/70 PDP-11/05 • PDP-11/10 • PDP-11/04 • PDP-11/34 • PDP-11/60 • PDP-11/44 • PDP-11/24 • PDP-11/84 • PDP-11/94 QBUS PDP-11s - PDP-11/03 • PDP-11/23 • PDP-11/23+ • MicroPDP-11/73 • MicroPDP-11/53 • MicroPDP-11/83 • MicroPDP-11/93 QBUS CPUs: LSI-11 • LSI-11/2 • KDF11-A • KDF11-B • KDJ11-A • KDJ11-B • KDJ11-D • KDJ11-E Buses: UNIBUS • UNIBUS map • SPC • MUD • EUB • QBUS • CD interconnect • PMI Also: PDP-11 architecture • PDP-11 Extended Instruction Set • FP11 floating point • PDP-11 Memory Management |
UNIBUS CPUs: KA11 • KC11 • KB11-A • KB11-B • KB11-C • KB11-D • KD11-A • KD11-B • KD11-D • KD11-E • KD11-EA • KD11-K • KD11-Z • KDF11-U
Co-processors: FP11-A • FP11-B • FP11-C • FP11-E • FP11-F • KE44-A • FPF11 Chips: LSI-11 • KEV11-A • KEV11-B • KEV11-C • F-11 • KEF11-A • KTF11-A • T-11 • J-11 • FPJ11 CPU options: KE11-E • KE11-F • KJ11-A • KT11-C • KT11-D • KK11-A • KK11-B • KT24 • KTJ11-B Rare CPU options: KS11 Memory Protection and Relocation option • KT11-B Paging Option • KUV11 Writeable Control Store Front panels: KY11-A • KY11-D • KY11-J • KY11-LA • KY11-LB • KY11-P More on buses: UNIBUS and QBUS termination • Bus Arbitration on the Unibus and QBUS • CTI BUS PDT-11s - PDT-11/110 • PDT-11/130 • PDT-11/150 CTI PDP-11s - PRO-325 • PRO-350 • PRO-380 Other: FIS floating point • PDP-11 Commercial Instruction Set • PDP-11 stacks • PDP-11 family differences |